{"name":"煤矿安全检查作业题库","level":"待补充","org":"应急管理部门","count":300,"questions":[{"id":1,"type":"single","stem":"煤矿井下用于检测甲烷浓度的便携式光学瓦斯检定器，其气路中安装的二氧化碳吸收管在每次测定前必须检查的内容是","options":["吸收管内的钠石灰是否失效变色","吸收管与气球连接是否漏气","吸收管外壳是否有防爆标志","吸收管是否注满蒸馏水"],"answer":[0],"explanation":"知识点：光学瓦斯检定器测定前检查项目。正确项：钠石灰失效会失去吸收二氧化碳的能力，导致测定结果偏高，必须检查其是否变色失效。错误项：连接漏气属于气密性检查，不是吸收管本身必须检查的内容；防爆标志与吸收管功能无关；吸收管内装钠石灰而非蒸馏水，注水说法错误。"},{"id":2,"type":"single","stem":"煤矿安全检查工在采煤工作面回风隅角发现甲烷浓度达到1.2%时，现场应首先采取的处置措施是","options":["停止工作撤出人员并切断电源","加大风量继续观察浓度变化","安排专人站在隅角处监测","用水管喷洒隅角降低浓度"],"answer":[0],"explanation":"知识点：采掘工作面甲烷超限处置。正确项：回风隅角甲烷达到1.0%即超限，必须停止作业、撤人、切断电源。错误项：加大风量继续观察不能替代撤人断电，属冒险作业；专人监测不消除危险源；喷水不能解决瓦斯积聚问题。"},{"id":3,"type":"single","stem":"煤矿井下安全检查中发现局部通风机发生循环风，其直接危害是","options":["使掘进工作面有效风量减少并可能造成瓦斯积聚","使局部通风机电机温度升高而烧毁","使风筒内风压升高导致风筒破裂","使掘进工作面温度下降影响作业"],"answer":[0],"explanation":"知识点：循环风危害。正确项：循环风把污风重新送入工作面，有效风量减少，瓦斯和粉尘无法排出，易造成瓦斯积聚。错误项：电机温升不是循环风的直接危害；风压升高破裂不是循环风特征；温度下降不是主要危害。"},{"id":4,"type":"single","stem":"煤矿安全检查工检查井下电气设备时，发现某台开关的隔爆外壳紧固螺栓缺失一颗，正确的判定是","options":["属于失爆，必须停止使用并处理","只要剩余螺栓拧紧即可继续运行","可用铁丝临时绑扎后继续使用","待下次检修时再补装螺栓"],"answer":[0],"explanation":"知识点：隔爆电气设备失爆判定。正确项：隔爆外壳紧固螺栓缺失使隔爆性能失效，属失爆，必须立即停用处理。错误项：少一颗螺栓即破坏隔爆结合面，不能继续运行；铁丝绑扎不能恢复隔爆性能；带病运行违反规程。"},{"id":5,"type":"single","stem":"煤矿井下爆破作业中，安全检查工发现爆破工在装药前未清除炮眼内的煤粉，正确的处置是","options":["制止装药，要求清除煤粉后再装药","允许装药但要求减少装药量","允许装药但要求增加封泥长度","要求爆破工改用反向装药"],"answer":[0],"explanation":"知识点：爆破装药前炮眼清理要求。正确项：炮眼内煤粉未清除会造成装药不实、爆破效果差甚至引燃瓦斯煤尘，必须清除后装药。错误项：减少装药量不能消除煤粉危害；增加封泥长度与炮眼内煤粉无关；反向装药不能替代清孔且本身有严格条件。"},{"id":6,"type":"single","stem":"煤矿安全检查工在检查主要通风机运行状况时，发现风机轴承温度超过规定值，正确的处理程序是","options":["报告矿调度并按规定停机检查","继续运行待温度自行下降","加大风量强制冷却轴承","降低风机转速继续运行"],"answer":[0],"explanation":"知识点：主要通风机异常处置。正确项：轴承超温可能造成设备损坏和通风中断，应报告调度并按规程停机检查。错误项：继续运行会扩大故障；加大风量不能解决轴承故障；降速运行仍带病运转，不能替代停机检查。"},{"id":7,"type":"single","stem":"煤矿井下安全检查工发现某掘进工作面风筒末端距工作面距离超过作业规程规定，其可能造成的后果是","options":["工作面有效风量不足形成瓦斯积聚","风筒内风速过高磨损风筒","局部通风机电流增大","风筒接头处漏风减少"],"answer":[0],"explanation":"知识点：风筒末端距离规定。正确项：风筒末端距工作面过远，射流达不到工作面，有效风量不足，易形成瓦斯积聚。错误项：风筒末端远不会使风筒内风速过高；与风机电流增大无直接关系；风筒接头漏风与末端距离无关。"},{"id":8,"type":"single","stem":"煤矿安全检查工在井下发现有人携带烟草和点火物品，正确的处置是","options":["立即制止并按规定报告处理","暂扣物品后允许其继续作业","登记后让其下班时带出井","劝其交出后不再追究"],"answer":[0],"explanation":"知识点：井下严禁烟火管理。正确项：携带烟草和点火物品入井属严重违章，必须立即制止并报告处理。错误项：暂扣后继续作业放纵违章；登记后带出井未消除当场危险；劝交不追究不能纠正违章。"},{"id":9,"type":"single","stem":"煤矿安全检查工检查采煤工作面支护时，发现单体液压支柱初撑力普遍偏低，正确的分析是","options":["顶板来压时支柱易失效导致冒顶","支柱初撑力低可节省乳化液","初撑力低有利于支柱回收","初撑力低不影响顶板管理"],"answer":[0],"explanation":"知识点：单体液压支柱初撑力作用。正确项：初撑力偏低不能及时支撑顶板，来压时易造成支柱失效和冒顶。错误项：节省乳化液不是安全理由；有利于回收说法颠倒主次；初撑力是顶板管理关键参数，不能说不影响。"},{"id":10,"type":"single","stem":"煤矿井下安全检查工发现某处密闭墙前瓦斯浓度达到2.0%，正确的处置是","options":["撤出附近人员并切断电源设置警戒","打开密闭墙进行通风排放","用风筒向密闭墙前供风稀释","在密闭墙前继续作业并监测"],"answer":[0],"explanation":"知识点：密闭墙前瓦斯超限处置。正确项：瓦斯达到2.0%必须撤人、断电、设警戒，防止人员误入和火源引爆。错误项：擅自打开密闭会放出大量瓦斯，极危险；用风筒供风不能替代撤人断电；继续作业严重冒险。"},{"id":11,"type":"single","stem":"煤矿安全检查工在检查井下消防器材时，发现灭火器压力表指针处于红区，正确的判定是","options":["灭火器失效需更换或重新充装","压力不足但可继续使用","指针在红区表示压力正常","只需摇动灭火器即可恢复"],"answer":[0],"explanation":"知识点：灭火器压力表判读。正确项：指针在红区表示压力不足，灭火器已失效，需更换或重新充装。错误项：压力不足不能继续使用；红区不是正常状态；摇动不能恢复压力。"},{"id":12,"type":"multi","stem":"煤矿安全检查工在井下发现下列哪些情形时，应当立即停止作业并撤出人员","options":["采掘工作面甲烷浓度超过规定限值","局部通风机停止运转且未恢复","工作面出现透水征兆且未处理","井下电气设备外壳温度略高于环境温度","巷道内粉尘浓度略高于日常水平"],"answer":[0,1,2],"explanation":"知识点：立即停止作业撤人的情形。正确项：瓦斯超限、局扇停风未恢复、透水征兆均属必须立即撤人的重大隐患。错误项：设备外壳略高于环境温度不能判定为异常，需按规程判断；粉尘略高于日常水平应加强降尘但不属立即撤人情形。"},{"id":13,"type":"single","stem":"井下安全检查中发现局部通风机风筒末端距掘进工作面距离超过作业规程规定，检查人员应首先采取的措施是","options":["要求立即停止掘进作业并撤出人员","现场记录后升井再向矿调度汇报","协助班组将风筒接长至规定距离","口头提醒班组长注意下一班整改"],"answer":[0],"explanation":"知识点：掘进工作面风筒末端距离超限会导致工作面风量不足、瓦斯积聚，属于重大隐患。正确项：先停止作业撤人，防止瓦斯超限引发事故。错误项：现场记录后升井汇报延误处置时机；协助接长风筒是生产行为，不能代替停止作业撤人；口头提醒下一班整改放任本班风险持续。"},{"id":14,"type":"single","stem":"煤矿井下爆破作业执行“一炮三检”制度时，检查人员应确认的检查次数是","options":["装药前、放炮前、放炮后各检查一次瓦斯","放炮前检查一次、放炮后检查一次","装药前检查一次、放炮后检查两次","放炮前检查两次、放炮后检查一次"],"answer":[0],"explanation":"知识点：一炮三检指装药前、放炮前、放炮后三个环节各检查一次瓦斯。正确项：三次检查覆盖爆破全过程瓦斯变化关键节点。错误项：少检装药前无法发现装药时瓦斯异常；只查两次漏掉关键环节；装药前一次加放炮后两次不能替代放炮前检查；放炮前两次放炮后一次同样遗漏装药前检查。"},{"id":15,"type":"single","stem":"井下安全检查发现采煤工作面液压支架初撑力普遍低于作业规程要求，正确的处置程序是","options":["责令立即停止采煤并督促补液升架至合格","要求支架工在采煤机通过时顺便补液","记录后由区队自行安排时间处理","降低采煤机牵引速度后继续作业"],"answer":[0],"explanation":"知识点：初撑力不足会导致顶板离层、冒顶，属重大隐患。正确项：立即停止采煤并补液升架至合格，消除顶板风险。错误项：采煤机通过时补液无法保证初撑力且危险；交由区队自行安排缺乏监督；降低牵引速度与初撑力无关，不能消除隐患。"},{"id":16,"type":"single","stem":"煤矿井下安全检查作业人员发现瓦斯检查工在采煤工作面上隅角检查瓦斯时未使用瓦斯检查杖，应认定为","options":["瓦斯检查工违章作业","瓦斯检查工正常操作","仪器配备不足问题","通风系统不合理问题"],"answer":[0],"explanation":"知识点：瓦斯检查工必须在规定地点用检查杖伸入检测，上隅角属高冒区易积聚瓦斯。正确项：未使用检查杖属违章作业，不能真实反映上隅角瓦斯浓度。错误项：正常操作说法错误；仪器配备不足属管理原因但不能免除违章性质；通风系统不合理与该违章无直接因果关系。"},{"id":17,"type":"single","stem":"井下安全检查中测得某掘进巷道回风流瓦斯浓度为1.2%，检查人员应要求现场","options":["停止工作、切断电源、撤出人员并汇报","加强通风后继续掘进作业","安排专人盯着瓦斯变化继续作业","暂停掘进但保留电气设备电源"],"answer":[0],"explanation":"知识点：掘进巷道回风流瓦斯浓度达到1%即须停止工作、撤人、切断电源。正确项：按规程立即停止作业、切断电源、撤出人员并汇报。错误项：继续掘进违反瓦斯超限停工规定；专人盯守不能代替停工撤人；保留电源存在引爆风险。"},{"id":18,"type":"single","stem":"检查煤矿井下使用的局部通风机时，发现其安装位置距回风口过近，正确的判断是","options":["可能造成循环风，属通风隐患","有利于吸入新鲜风流","可提高局部通风机效率","对通风系统没有影响"],"answer":[0],"explanation":"知识点：局部通风机距回风口过近会吸入污风形成循环风，导致工作面风量不足、瓦斯积聚。正确项：判定为循环风隐患。错误项：靠近回风口吸入的是污风而非新鲜风；不会提高效率反而降低有效风量；对通风系统有直接影响。"},{"id":19,"type":"single","stem":"煤矿井下安全检查发现某处电缆与风水管路同侧敷设且间距不足，正确的处置意见是","options":["责令按规程要求保持规定间距或采取隔离措施","要求将电缆悬挂高度降低避开管路","要求把风水管路改为埋地敷设","允许同侧敷设但加强日常巡视"],"answer":[0],"explanation":"知识点：电缆与风水管路同侧敷设须保持规定间距，防止管路漏水电击或电缆受损。正确项：责令保持规定间距或采取隔离措施。错误项：降低电缆高度不能解决间距不足；管路改埋地在井下多不可行且非检查要求；加强巡视不能消除间距不足的固有隐患。"},{"id":20,"type":"single","stem":"井下安全检查中发现某作业地点甲烷传感器显示数值与人工检测数值差异较大，检查人员应首先","options":["以人工检测数据为准组织撤人并查明原因","以传感器数据为准继续作业","取两者平均值判断是否超限","等传感器自动校准后再作判断"],"answer":[0],"explanation":"知识点：甲烷传感器与人工检测不一致时，应按就高原则以人工检测为准，先保证安全。正确项：以人工检测为准撤人并查明传感器故障原因。错误项：以传感器为准可能漏报超限；取平均值无依据；等待自动校准会延误撤人时机。"},{"id":21,"type":"single","stem":"煤矿井下安全检查作业中，发现采煤工作面上下安全出口高度不足、行人困难，应认定为","options":["违反安全出口畅通规定的隐患","正常的生产条件波动","可由班组自行决定是否处理","只影响行人效率不影响安全"],"answer":[0],"explanation":"知识点：采煤工作面上下安全出口必须保证规定高度和畅通，是撤人通道。正确项：认定违反安全出口畅通规定的隐患。错误项：非正常波动而是隐患；不能由班组自行决定；安全出口不畅直接影响撤离安全。"},{"id":22,"type":"single","stem":"井下安全检查发现某掘进工作面未按规定设置风电闭锁和瓦斯电闭锁，正确的处置是","options":["责令停止掘进并限期整改闭锁装置","允许先掘进后补装闭锁装置","要求加强人工监测代替闭锁装置","仅在夜班安排专人看管风机"],"answer":[0],"explanation":"知识点：风电闭锁和瓦斯电闭锁是掘进工作面防止瓦斯积聚和电气引爆的重要保护。正确项：停止掘进并限期整改。错误项：先掘进后补装使作业处于无保护状态；人工监测不能替代闭锁功能；专人看管风机不能实现瓦斯超限自动断电。"},{"id":23,"type":"single","stem":"煤矿井下安全检查作业人员进入采空区附近检查时，正确的做法是","options":["先检查瓦斯和支护情况再决定是否进入","直接进入查看采空区垮落情况","结伴进入并快速通过不检测","在采空区口观察后即可进入"],"answer":[0],"explanation":"知识点：采空区附近易积聚瓦斯、顶板不稳定，进入前须检测瓦斯和检查支护。正确项：先检测瓦斯、检查支护再决定进入。错误项：直接进入不检测风险极大；结伴快速通过仍不检测；在口观察不能代表内部安全。"},{"id":24,"type":"multi","stem":"井下安全检查中发现下列哪些情形应当责令立即停止作业并撤出人员","options":["采掘工作面瓦斯浓度超过规定限值","通风系统不稳定、风流短路","顶板出现明显离层且支护失效","作业地点温度略高于平时","巷道内个别照明灯不亮"],"answer":[0,1,2],"explanation":"知识点：瓦斯超限、通风系统不稳定、顶板离层支护失效均属立即停止作业撤人的重大隐患。正确项：三项均直接威胁人员安全须立即停工撤人。错误项：温度略高属一般环境问题，可加强监测；个别照明灯不亮属一般隐患，安排处理即可。"},{"id":25,"type":"single","stem":"煤矿井下安全检查工在检查采煤工作面支柱时，发现个别单体液压支柱初撑力不足，正确的处理方式是","options":["要求立即补液升柱并复查合格后再允许作业","用木楔在柱顶塞紧后继续生产","等本班结束后统一安排补液","在支柱上挂牌注明并移交下一班处理"],"answer":[0],"explanation":"知识点：支护质量隐患的现场处置。初撑力不足须立即补液升柱并复查，消除隐患后方可作业。错误项'木楔塞紧'不能提供设计初撑力，属临时凑合；'班后统一补液'期间工作面处于不安全状态；'挂牌移交下班'未消除当班隐患，违反隐患即查即改要求。"},{"id":26,"type":"single","stem":"安全检查工在掘进工作面发现局部通风机因故停止运转，恢复通风前必须先检查的项目是","options":["检查停风区内的甲烷浓度和二氧化碳浓度","检查局部通风机电机温度是否正常","检查风筒吊挂是否平直牢固","检查掘进工作面迎头积尘厚度"],"answer":[0],"explanation":"知识点：恢复通风前的气体检查。停风区恢复通风前必须检查甲烷和二氧化碳浓度，确认不超限方可启动风机。错误项'电机温度'属于设备状态检查，不是恢复通风的前置气体条件；'风筒吊挂'是日常质量检查项目；'积尘厚度'与恢复通风的气体安全条件无直接关系。"},{"id":27,"type":"single","stem":"煤矿井下爆破作业中，安全检查工发现爆破工准备使用发爆器时未执行'三人连锁'制度，正确的处置是","options":["立即制止爆破作业，待连锁制度落实到位后方可起爆","要求爆破工加快装药速度缩短影响时间","提醒爆破工下次注意后允许本次起爆","让班组长代替爆破工执行连锁确认"],"answer":[0],"explanation":"知识点：爆破'三人连锁'制度。爆破前爆破工、班组长、瓦斯检查工必须共同确认并执行连锁，缺一不可起爆。错误项'加快装药'回避了制度缺失；'下次注意'放任本次违章；'班组长代替'破坏了三人各自职责的连锁确认要求。"},{"id":28,"type":"single","stem":"煤矿安全规程规定，采掘工作面进风流中按体积计算的氧气浓度不得低于","options":["18%","19%","20%","21%"],"answer":[2],"explanation":"知识点：井下空气中氧气浓度标准。规程规定采掘工作面进风流中氧气浓度不得低于20%。错误项18%和19%低于规定下限，人员在此环境中易出现缺氧症状；21%是地面空气正常值，不是规程规定的最低限值。"},{"id":29,"type":"single","stem":"安全检查工在井下巷道中发现一氧化碳浓度持续升高且伴有煤油味，最可能的情况是","options":["煤层自然发火征兆","井下柴油设备尾气排放","放炮后炮烟未散尽","人员呼吸产生的二氧化碳积聚"],"answer":[0],"explanation":"知识点：煤炭自然发火标志气体。一氧化碳持续升高并伴煤油味是煤炭自燃的典型征兆。错误项'柴油尾气'会随设备停止而下降且不伴煤油味；'炮烟'为放炮后短时出现并逐渐消散；'人员呼吸'产生二氧化碳而非一氧化碳。"},{"id":30,"type":"single","stem":"井下发生瓦斯爆炸事故后，安全检查工在未被波及区域组织人员撤离时，正确的撤离方向是","options":["沿进风巷道撤向地面","沿回风巷道撤向采空区","就近进入盲巷躲避","逆着爆炸冲击波方向穿过灾区"],"answer":[0],"explanation":"知识点：瓦斯爆炸后撤离路线选择。应沿进风巷道向地面撤离，避免进入回风侧和盲巷。错误项'回风巷道撤向采空区'会进入有毒有害气体区域；'盲巷躲避'易造成窒息；'逆冲击波穿灾区'会直接遭遇爆炸和有毒气体。"},{"id":31,"type":"single","stem":"煤矿井下使用的矿灯，安全检查工在入井前检查时应重点确认的是","options":["矿灯灯锁、灯头圈是否紧固且电池盒无破损","矿灯灯泡的额定功率是否达到规定值","矿灯电池的充电时间是否超过8小时","矿灯外壳颜色是否符合区队标识要求"],"answer":[0],"explanation":"知识点：矿灯入井前检查项目。须检查灯锁、灯头圈紧固情况以及电池盒有无破损，防止井下失爆。错误项'灯泡额定功率'属于产品参数而非入井检查重点；'充电时间'由充电工管理；'外壳颜色'与安全性能无关。"},{"id":32,"type":"single","stem":"安全检查工在检查井下电气设备时，发现隔爆型开关的隔爆结合面有油漆涂层，正确的判断是","options":["该设备已失去隔爆性能，须停止使用并处理","油漆可防锈，不影响隔爆性能","只要结合面间隙合格即可继续使用","涂漆后隔爆等级提高，可正常使用"],"answer":[0],"explanation":"知识点：隔爆设备隔爆结合面要求。结合面不得涂漆，否则会影响隔爆性能。错误项'防锈不影响'忽略了油漆改变结合面间隙和传爆路径；'间隙合格即可'忽视了涂层本身对隔爆面的破坏；'等级提高'与事实相反。"},{"id":33,"type":"single","stem":"井下采煤工作面采用垮落法管理顶板时，安全检查工发现采空区悬顶面积超过作业规程规定，应当","options":["责令停止作业并按规程要求强制放顶","要求作业人员加快回柱速度自然垮落","在悬顶区域下方增设临时支护后继续作业","记录悬顶情况待周期来压时观察处理"],"answer":[0],"explanation":"知识点：采空区悬顶处理。悬顶超过规定须停止作业并强制放顶。错误项'加快回柱自然垮落'无法保证及时垮落且增加危险；'临时支护后继续作业'不能消除大面积悬顶隐患；'待周期来压观察'属于冒险等待，可能引发大面积来压事故。"},{"id":34,"type":"single","stem":"井下巷道维修时发现顶板有离层征兆但暂未掉落，安全检查工应要求作业人员首先采取的措施是","options":["立即撤出人员并设置警戒禁止通行","先派一人用长柄工具敲帮问顶确认","加快支护进度抢在掉落前完成","在离层处下方架设临时点柱支撑"],"answer":[0],"explanation":"知识点：顶板离层是最危险的冒顶前兆，处置程序是先撤人后处理。正确项对：发现离层征兆时人员安全优先，必须先撤出并设警戒，防止冒顶伤人。A错在未先撤人就派人近前操作，人员暴露在危险顶板下；B错在抢进度忽视了随时可能冒顶的风险；C错在离层已出现，临时点柱不能消除突然冒落威胁。"},{"id":35,"type":"single","stem":"煤矿井下安全检查中发现局部通风机停风，恢复通风前必须先检查的内容是","options":["检查风筒是否完好有无破口","检查停风区域内的瓦斯浓度","检查风机开关是否处于断电状态","检查该区域作业人员是否全部撤离"],"answer":[1],"explanation":"知识点：停风区域恢复通风前必须先检查瓦斯，防止瓦斯积聚遇火源爆炸。正确项对：瓦斯浓度是决定能否直接恢复通风或需排放的关键依据。A错在风筒完好性虽重要但不是恢复通风的前置条件；C错在开关状态属于操作环节，不能替代瓦斯检查；D错在人员撤离情况应先确认但核心前置检查是瓦斯。"},{"id":36,"type":"single","stem":"安全检查工在采煤工作面发现支架液压管路有渗漏且压力表读数偏低，正确的处置顺序是","options":["先记录渗漏位置再通知维修人员处理","先通知泵站升压再检查渗漏部位","先撤出工作面人员再组织更换管路","先停止采煤机运行再处理渗漏管路"],"answer":[0],"explanation":"知识点：支架初撑力不足是顶板事故重要诱因，渗漏和压力偏低表明支护系统失效。正确项对：先准确记录渗漏位置和压力情况，再通知专业维修处理，既保证信息完整又不擅自操作。A错在擅自升压可能加剧渗漏甚至爆管；B错在撤人范围过大且未先查明原因；C错在停机不等于支护问题解决，渗漏仍需专业处理。"},{"id":37,"type":"single","stem":"瓦斯检查工在掘进工作面回风流中检测到瓦斯浓度达到1.2%，安全检查工应要求该区域","options":["加强通风继续作业但禁止爆破","立即停止作业撤出人员并断电","安排专人监测瓦斯变化再决定","降低掘进速度减少瓦斯涌出"],"answer":[1],"explanation":"知识点：采掘工作面回风流瓦斯浓度超过1.0%时必须停止作业、撤人、断电。正确项对：1.2%已超过规定限值，必须立即停止作业撤出人员并切断电源。A错在超限后不允许继续作业；B错在专人监测不能替代撤人断电措施；C错在降低速度不能解决瓦斯超限问题。"},{"id":38,"type":"single","stem":"井下安全检查发现某掘进巷道锚杆支护的托盘未贴紧岩面、部分锚杆外露过长，这属于","options":["锚杆安装质量问题需补打更换","锚杆材质不合格需取样送检","围岩压力过大需加密支护","锚固剂用量不足需重新搅拌"],"answer":[0],"explanation":"知识点：锚杆托盘不贴岩面、外露过长是安装质量问题，会导致锚杆失效。正确项对：托盘未贴紧岩面使锚杆无法提供有效支护力，属于安装不合格需补打或更换。A错在题干未提示材质问题；B错在压力过大表现为变形而非托盘不贴；C错在锚固剂用量问题表现为锚固力不足而非外露过长。"},{"id":39,"type":"single","stem":"安全检查工在井下发现电缆与风管、水管同侧吊挂且间距不足，正确的判断是","options":["电缆应挂在管子上方并保持规定间距","电缆与管路同侧吊挂但需加设保护套","电缆应改为落地敷设避免与管路干扰","电缆与管路可同侧但必须用同一吊钩"],"answer":[0],"explanation":"知识点：井下电缆应与管路分侧悬挂，同侧时电缆必须在管路上方并保持规定距离。正确项对：电缆挂在管路上方可防止管路检修时损伤电缆，间距要求防止相互干扰。A错在加保护套不能替代间距要求；B错在落地敷设易受潮和机械损伤；C错在共用吊钩无法保证间距且检修时易误伤电缆。"},{"id":40,"type":"single","stem":"井下爆破作业后，安全检查工进入工作面检查的时机应是","options":["爆破后立即进入检查爆破效果","等炮烟吹散且通风正常后进入","等爆破工收拾完工具后进入","听到爆破声响后即可进入检查"],"answer":[1],"explanation":"知识点：爆破后炮烟含大量有毒气体，必须等通风吹散后方可进入。正确项对：炮烟吹散且通风正常是进入检查的安全前提。A错在立即进入会吸入炮烟中毒；B错在收拾工具与安全条件无关；C错在听到声响不代表炮烟已散。"},{"id":41,"type":"single","stem":"安全检查工在井下发现某处瓦斯传感器显示数值长时间不变，正确的处置是","options":["用光学瓦斯检定器对照检测核实","直接判定传感器故障并报修","记录该异常待下班后统一上报","调整传感器位置使其读数正常"],"answer":[0],"explanation":"知识点：瓦斯传感器读数异常时应用光学检定器人工对照检测。正确项对：人工对照检测可判断是传感器故障还是真实数据。A错在未核实就判定故障可能漏掉真实超限；B错在异常需及时上报不能拖延；C错在调整位置掩盖问题属于违规。"},{"id":42,"type":"single","stem":"井下发生火灾时，安全检查工在判断风流方向后应组织人员","options":["迎风撤退到进风侧新鲜风流中","就地寻找避难硐室等待救援","顺风撤退到回风侧等待升井","先灭火再根据火势决定撤退"],"answer":[0],"explanation":"知识点：井下火灾撤离应迎风撤退到进风侧，避开火烟蔓延方向。正确项对：进风侧新鲜风流方向是安全撤离路线。A错在就地等待可能被火烟包围；B错在回风侧正是火烟蔓延方向；C错在火势不明时先灭火会延误撤离时机。"},{"id":43,"type":"single","stem":"安全检查工发现井下某处密闭墙外有瓦斯涌出且墙内可能有积水，应重点检查的是","options":["密闭墙的墙体裂缝和瓦斯浓度","密闭墙内积水水位和温度","密闭墙附近巷道支护完好情况","密闭墙施工时间和材料配比"],"answer":[0],"explanation":"知识点：密闭墙外瓦斯涌出说明墙内气体外泄，需检查墙体完整性和瓦斯浓度。正确项对：裂缝是瓦斯外泄通道，瓦斯浓度决定是否需撤人断电。A错在积水水位不是首要检查项；B错在支护情况与瓦斯涌出无直接关系；C错在施工时间材料属于历史资料。"},{"id":44,"type":"single","stem":"安全检查工在采煤工作面发现上下安全出口高度不足、有杂物堆积，正确的处理是","options":["要求立即清理杂物并恢复出口高度","记录后待检修班统一处理","安排人员从其他出口通行即可","在出口处设置警示标志后继续作业"],"answer":[0],"explanation":"知识点：安全出口必须保证规定高度和畅通，是人员撤离的生命通道。正确项对：必须立即清理并恢复高度，不能拖延。A错在待检修班处理会延误；B错在绕行不能替代出口畅通要求；C错在设警示不等于消除隐患。"},{"id":45,"type":"multi","stem":"安全检查工在井下进行隐患排查时，下列属于必须立即停止作业并撤出人员的情形有","options":["采掘工作面瓦斯浓度超过规定限值","工作面顶板出现明显离层且持续掉渣","局部通风机因故障停止运转","井下某处照明灯具亮度不足","巷道内个别锚杆托盘轻微松动"],"answer":[0,1,2],"explanation":"知识点：瓦斯超限、顶板离层掉渣、停风都是立即撤人的重大隐患。正确项对：三项均直接威胁人员安全，必须立即撤人。A错在照明不足属一般隐患，可整改但不必撤人；B错在个别托盘轻微松动需处理但不构成立即撤人条件。"},{"id":46,"type":"single","stem":"井下安全检查工在采煤工作面回风隅角检测到甲烷浓度达到1.2%时，现场应首先采取的措施是","options":["停止工作、撤出人员并切断电源","加强通风后继续作业并加密检测","洒水降尘降低甲烷浓度","安排专人监视后维持生产"],"answer":[0],"explanation":"知识点：甲烷超限处置。回风隅角甲烷达到1.0%即须停止工作、撤人、断电。B项继续作业违反超限停产要求；C项洒水不能降低甲烷浓度；D项监视生产不能替代撤人断电。"},{"id":47,"type":"single","stem":"煤矿井下爆破作业执行'一炮三检'制度时，三次检查分别对应的工序是","options":["装药前、放炮前、放炮后","打眼前、装药前、放炮后","装药前、连线前、放炮前","打眼前、连线前、放炮后"],"answer":[0],"explanation":"知识点：一炮三检。指装药前、放炮前、放炮后三次检查瓦斯。B、D把打眼工序混入；C把连线当成检查节点，均不符合规定节点。"},{"id":48,"type":"single","stem":"安全检查工在掘进巷道发现局部通风机停止运转，此时正确的处置是","options":["撤出人员、切断电源并设置栅栏警标","立即启动风机恢复供风","安排人员进入检查停风原因","打开风筒接头自然通风后作业"],"answer":[0],"explanation":"知识点：停风处置。停风须撤人、断电、设栅栏警标。B未查瓦斯就启动可能引爆积聚瓦斯；C进入停风区有窒息和爆炸风险；D自然通风无法保证风量且未撤人。"},{"id":49,"type":"single","stem":"下列哪项属于采煤工作面顶板管理中'来压预报'重点关注的内容","options":["支架活柱下缩量与顶板下沉速度","工作面风流中二氧化碳浓度","采煤机滚筒截齿磨损程度","刮板输送机链条张紧度"],"answer":[0],"explanation":"知识点：顶板来压预报指标。活柱下缩量和顶板下沉速度是判断来压的关键参数。B属通风监测；C属设备维护；D属运输设备检查，均与顶板来压预报无关。"},{"id":50,"type":"single","stem":"井下安全检查发现某处电缆与风管、水管同侧吊挂且电缆位于管路上方，正确的判断是","options":["电缆应在管路上方并保持0.3米以上距离","电缆应挂在管路下方并保持0.3米以上距离","电缆与管路可同侧但须用同一吊钩固定","电缆与管路同侧时电缆应在上方且紧贴管路"],"answer":[0],"explanation":"知识点：井下电缆悬挂。电缆应挂在管子上方并保持0.3米以上距离，以防管路漏水或维修损伤电缆。B位置颠倒；C同一吊钩固定不符合分挂要求；D紧贴管路无安全距离。"},{"id":51,"type":"single","stem":"安全检查工进入盲巷检查前，必须确认的条件是","options":["瓦斯浓度不超限且氧气浓度符合规定","盲巷内积水已排空且支护完好","盲巷长度不超过6米且无积尘","盲巷口已设置临时风门且风量稳定"],"answer":[0],"explanation":"知识点：盲巷进入条件。盲巷易积聚瓦斯和缺氧，进入前必须检测瓦斯和氧气合格。B积水支护不是进入的首要前提；C长度积尘不是准入条件；D设风门也不能替代气体检测。"},{"id":52,"type":"single","stem":"采掘工作面采用串联通风时，被串联工作面的进风流中甲烷浓度必须控制在","options":["0.5%以下","0.8%以下","1.0%以下","1.5%以下"],"answer":[0],"explanation":"知识点：串联通风要求。被串联工作面进风流中甲烷浓度不得超过0.5%。B、C、D数值均高于规定限值，串联通风对进风流瓦斯要求更严。"},{"id":53,"type":"single","stem":"井下发生煤尘爆炸后，安全检查工在灾区外围正确的首要行动是","options":["报告调度室并按避灾路线组织撤离","立即进入灾区抢救遇险人员","先切断灾区所有通信线路防止引爆","在巷道口打开风门加大通风排除有害气体"],"answer":[0],"explanation":"知识点：爆炸事故应急处置。首要行动是报告调度并按避灾路线撤离。B盲目进入灾区可能中毒或遇二次爆炸；C切通信不利于救援指挥；D打开风门可能造成风流紊乱扩大灾情。"},{"id":54,"type":"single","stem":"安全检查工在井下发现有人触电，在电源未切断前正确的做法是","options":["用干燥木棍等绝缘物挑开电源线使触电者脱离","直接用手拉拽触电者脱离电源","用湿布包裹手部后拉拽触电者","等待电工到场后再进行施救"],"answer":[0],"explanation":"知识点：触电急救。电源未切断时应用绝缘物使触电者脱离电源。B直接拉拽会导致施救者触电；C湿布不绝缘反而导电；D等待会延误抢救时机。"},{"id":55,"type":"single","stem":"井下运送爆炸材料时，安全检查工发现押运人员与爆炸材料同乘一辆车，正确的判断是","options":["押运人员可同乘但爆炸材料须装箱固定","押运人员不得与爆炸材料同乘一辆车","只要车速不超过规定即可同乘","同乘时须将爆炸材料置于车厢尾部"],"answer":[1],"explanation":"知识点：爆炸材料运输。押运人员不得与爆炸材料同乘一辆车。A、C、D均以不同理由允许同乘，违反运输安全规定，一旦发生意外后果严重。"},{"id":56,"type":"multi","stem":"安全检查工在采煤工作面发现下列哪些情形时，应当立即停止作业并撤出人员","options":["工作面甲烷浓度达到1.5%","支架严重变形且顶板持续掉渣","工作面出现明显透水征兆如挂红挂汗","采煤机滚筒截齿轻微磨损","回风巷粉尘浓度略高于日常水平"],"answer":[0,1,2],"explanation":"知识点：停产撤人情形。甲烷超限、顶板严重变形掉渣、透水征兆均属立即停产撤人情形。D截齿轻微磨损属日常维护；E粉尘略高应加强降尘但不属立即撤人情形。"},{"id":57,"type":"single","stem":"煤矿井下安全检查中，发现采煤工作面回风巷瓦斯浓度达到1.2%时，安全检查工应首先采取的措施是","options":["责令现场作业人员立即停止工作并切断电源撤出人员","要求瓦检员增加检测频次后继续观察","通知班组长安排人员加强通风后恢复作业","记录数据待升井后向调度室汇报处理"],"answer":[0],"explanation":"知识点：瓦斯超限应急处置。回风巷瓦斯浓度达到1.0%即须停止工作、撤人、断电。正确项对：1.2%已超限，必须立即停止作业、切断电源、撤出人员。错误项一错在：增检频次不能替代撤人断电，属于以观察代替处置。错误项二错在：超限状态下不得继续作业，加强通风须在撤人断电后进行。错误项三错在：超限属紧急情况，必须立即处置而非升井后汇报。"},{"id":58,"type":"single","stem":"煤矿安全检查工在检查井下电气设备时，发现一台馈电开关的接地保护装置动作后被人为短接，正确的处置方式是","options":["当场拆除短接线并恢复接地保护功能后记录隐患","要求电工班在当班结束前拆除短接线即可","先向矿调度汇报后再决定是否拆除短接线","责令停止该开关供电并追究短接人员责任"],"answer":[0],"explanation":"知识点：井下电气保护装置检查与隐患处置。接地保护被短接属重大隐患，安全检查工有权当场制止并恢复。正确项对：应立即拆除短接线恢复保护功能并记录隐患。错误项一错在：重大隐患不能延时到当班结束处理。错误项二错在：紧急隐患须先处置后汇报，不能等汇报再定。错误项三错在：追责是后续程序，首要是消除隐患恢复保护，且责令停电不是检查工直接操作权限的表述重点。"},{"id":59,"type":"single","stem":"煤矿安全规程规定，井下人员发现瓦斯爆炸事故后，在无法安全撤离的情况下，正确的避灾方法是","options":["背向爆炸冲击波方向卧倒并用水浸湿毛巾捂住口鼻","面向爆炸方向快速奔跑寻找新鲜风流出口","就地站立观察爆炸波及范围后再选择撤离路线","躲入附近机电硐室内关闭铁门等待救援"],"answer":[0],"explanation":"知识点：瓦斯爆炸事故避灾自救。正确项对：背向冲击波卧倒可减少冲击伤害，湿毛巾捂口鼻可过滤部分有害气体。错误项一错在：面向爆炸方向奔跑会直接承受冲击波和火焰。错误项二错在：站立观察会暴露于冲击波和高温气流中。错误项三错在：机电硐室可能积聚有害气体且非专用避难硐室，关闭铁门不能保证安全。"},{"id":60,"type":"single","stem":"煤矿安全检查工对井下主要通风机进行检查时，发现风机运转声音异常且电流表指针剧烈摆动，正确的做法是","options":["立即报告矿调度并通知机电部门检查处理","自行停机检查风机叶轮是否损坏","调整风机叶片角度使电流恢复平稳","等待交接班时向下一班检查工口头说明"],"answer":[0],"explanation":"知识点：主要通风机异常运行处置。正确项对：主要通风机异常直接威胁全矿通风安全，须立即报告调度并通知机电专业部门。错误项一错在：安全检查工无权自行停机，停机可能造成井下无风。错误项二错在：调整叶片角度是专业维修操作，非检查工职责且盲目调整有危险。错误项三错在：交接班口头说明会延误处置时机。"},{"id":61,"type":"single","stem":"在煤矿井下进行安全检查时，发现掘进工作面局部通风机风筒末端距工作面距离超过规定且存在循环风，正确的判定是","options":["属于通风管理重大隐患，须立即停止掘进并整改","属于一般隐患，提醒班组注意即可","属于设备安装问题，由通风队自行调整","属于正常现象，掘进面推进后自然消除"],"answer":[0],"explanation":"知识点：局部通风机通风隐患排查。风筒末端距工作面超规定且循环风会导致工作面风量不足、瓦斯积聚。正确项对：属重大隐患，须立即停止掘进整改。错误项一错在：循环风可致瓦斯超限，不是一般隐患。错误项二错在：循环风是通风系统问题，不能仅由通风队自行调整了事。错误项三错在：循环风不会随推进自然消除，须整改。"},{"id":62,"type":"single","stem":"煤矿安全检查工在井下检查爆破作业时，发现爆破工在装药前未检查瓦斯浓度，正确的处置是","options":["立即制止装药并要求先检测瓦斯浓度合格后再作业","要求爆破工补测一次瓦斯后继续装药","记录后向矿调度汇报由调度决定是否继续","提醒爆破工下次注意并允许本次继续作业"],"answer":[0],"explanation":"知识点：爆破作业前瓦斯检查规定。正确项对：装药前必须检查瓦斯，未检查即装药属严重违章，须立即制止。错误项一错在：补测后继续装药不能消除已发生的违章，且装药前检查是前置条件。错误项二错在：紧急违章须现场制止，不能等调度决定。错误项三错在：瓦斯超限爆破后果严重，不能以提醒代替制止。"},{"id":63,"type":"single","stem":"煤矿安全检查工在检查井下运输巷道时，发现一列矿车连接装置磨损量超过规定值但仍在使用，正确的处理是","options":["责令立即停止使用该连接装置并更换合格装置","要求降低牵引速度后继续使用该连接装置","通知运输队在该班运输任务完成后更换","在连接装置上做标记待下次检查时处理"],"answer":[0],"explanation":"知识点：矿车连接装置安全检查。正确项对：连接装置磨损超限有断链跑车风险，须立即停用更换。错误项一错在：降速不能消除断链风险。错误项二错在：带病运行一个班次仍存在事故可能。错误项三错在：做标记待下次处理会延误消除隐患。"},{"id":64,"type":"single","stem":"煤矿安全检查工发现井下某处巷道顶板出现新的裂隙且伴有淋水增大，正确的处置顺序是","options":["撤出受威胁人员、设置警戒、报告调度并通知地测部门","先通知地测部门观测、等待观测结果再决定是否撤人","先设置警戒、待顶板稳定后再撤出人员","先报告调度、由调度通知撤人后再设置警戒"],"answer":[0],"explanation":"知识点：顶板与透水预兆的应急处置。正确项对：裂隙加淋水增大可能是冒顶或透水前兆，须先撤人、设警戒、再报告。错误项一错在：等待观测结果会延误撤人时机。错误项二错在：应先撤人再等稳定，顺序颠倒。错误项三错在：设警戒与撤人应同步或先撤人，不能等调度通知后再设警戒。"},{"id":65,"type":"single","stem":"煤矿安全检查工在检查采煤机时，发现采煤机内外喷雾装置有一组喷嘴堵塞，正确的判断是","options":["属于必须立即处理的隐患，堵塞会导致降尘失效","属于可暂缓处理的问题，待检修班统一清理","属于正常磨损，不影响采煤机安全运行","属于生产班职责，由采煤机司机自行处理"],"answer":[0],"explanation":"知识点：采煤机喷雾降尘装置检查。正确项对：喷雾堵塞会使割煤产尘无法有效抑制，须立即处理。错误项一错在：堵塞期间持续割煤会造成粉尘超标，不能暂缓。错误项二错在：喷雾失效直接威胁防尘安全，不是正常磨损。错误项三错在：检查工发现隐患应责令处理，不能仅归为司机自行处理。"},{"id":66,"type":"multi","stem":"煤矿安全检查工在井下发现以下哪些情形时，应当责令立即停止作业并撤出人员","options":["采掘工作面瓦斯浓度超过规定限值","井下主要排水泵房被淹且水位持续上涨","局部通风机停止运转且短时间内无法恢复","井下某段巷道照明灯损坏两盏","运输大巷有一辆矿车掉道但未造成人员伤害"],"answer":[0,1,2],"explanation":"知识点：紧急停工撤人情形判定。正确项对：瓦斯超限、水淹泵房水位上涨、局部通风机停风均直接威胁人员安全，须立即停工撤人。错误项一错在：照明灯损坏属一般隐患，应整改但不构成立即撤人条件。错误项二错在：矿车掉道未伤人属运输一般隐患，应处理但不须全矿撤人。"},{"id":67,"type":"single","stem":"煤矿安全检查工在检查井下消防材料库时，发现灭火器压力表指针处于红色区域，正确的处置是","options":["责令立即更换合格灭火器并记录该隐患","要求将灭火器倒置摇晃后继续存放使用","在灭火器上标注失效日期待统一送检","通知库管员下次领用时更换即可"],"answer":[0],"explanation":"知识点：井下消防器材完好性检查。正确项对：压力表指针在红色区表示灭火器失效，须立即更换。错误项一错在：倒置摇晃不能恢复已失效灭火器的压力。错误项二错在：标注失效日期但继续存放会延误更换。错误项三错在：下次领用时更换不能保证当前消防器材可用。"},{"id":68,"type":"single","stem":"井下安全检查发现掘进工作面局部通风机停止运转但风筒末端仍有微风，检查人员应首先确认的是","options":["风筒是否出现破口漏风","局部通风机是否实现风电闭锁","工作面是否已停止作业撤人","备用风机是否处于完好状态"],"answer":[2],"explanation":"知识点：停风应急处置。局部通风机停转后，工作面可能积聚瓦斯，首要确认作业人员是否已停止作业并撤至安全地点，防止人员处于危险区域。风筒破口漏风是停风后可能的现象，但非首要确认事项；风电闭锁是设备功能，此时风机已停，确认它不能解决人员安全；备用风机状态是后续恢复通风考虑的内容，不是首步。"},{"id":69,"type":"single","stem":"煤矿井下安全检查中，测定巷道风流中瓦斯浓度时，甲烷检测仪吸气管应放置在","options":["巷道顶板最高处","巷道底板最低处","巷道断面中部靠上位置","风筒出风口正前方"],"answer":[2],"explanation":"知识点：瓦斯检测取样位置。瓦斯比空气轻，易积聚在巷道顶部，但检测巷道风流中瓦斯浓度应取具有代表性的断面中部靠上位置。顶板最高处容易测到局部积聚，不能代表风流整体；底板最低处不是瓦斯聚集位置；风筒出风口正前方是局部风流，不具代表性。"},{"id":70,"type":"single","stem":"井下某采煤工作面回风巷检查时发现一氧化碳浓度持续升高，检查人员正确的下一步处置是","options":["记录数据后继续检查其他项目","立即撤出人员并报告调度室","打开附近风门增加风量稀释","用瓦斯检测仪复核一氧化碳浓度"],"answer":[1],"explanation":"知识点：一氧化碳超限应急处置。一氧化碳持续升高可能预示自燃或火灾，必须立即撤人并报告。记录后继续检查会延误撤离；打开风门可能扰乱通风系统甚至助燃；一氧化碳不能用瓦斯检测仪复核，仪器功能不对。"},{"id":71,"type":"single","stem":"煤矿安全检查作业中，检查采煤机内喷雾装置时，判定其失效的直接依据是","options":["喷雾水压低于规定值","喷嘴有部分堵塞现象","割煤时粉尘浓度超标","喷雾水未覆盖滚筒截割区域"],"answer":[3],"explanation":"知识点：采煤机内喷雾有效性判定。内喷雾的作用是覆盖滚筒截割产尘区域，未覆盖该区域即判定失效。水压偏低、部分堵塞、粉尘超标都可能是原因或后果，但不能直接判定内喷雾失效。"},{"id":72,"type":"single","stem":"井下爆破作业后，安全检查人员进入爆破地点检查前必须确认的是","options":["爆破员已撤离到安全地点","炮烟已吹散且瓦斯浓度合格","爆破器材已全部回收入库","爆破母线已从起爆器上取下"],"answer":[1],"explanation":"知识点：爆破后进入检查条件。必须等炮烟吹散、有害气体和瓦斯浓度合格后方可进入。爆破员撤离、器材回收、母线取下都是爆破管理要求，但不是进入检查前对现场环境的直接确认条件。"},{"id":73,"type":"single","stem":"井下安全检查发现某处电缆与压风管同侧敷设且间距不足，正确的处理意见是","options":["要求电缆穿管保护后即可","要求电缆与压风管保持规定间距","要求将电缆改挂在压风管上方","要求压风管加设隔热层后即可"],"answer":[1],"explanation":"知识点：井下管线敷设间距要求。电缆与压风管应保持规定间距，防止管路受损或漏气影响电缆。穿管保护、改挂上方、加隔热层都不能替代间距要求。"},{"id":74,"type":"single","stem":"煤矿井下安全检查中，对临时停工的掘进工作面，检查重点应是","options":["是否已收回所有工具","是否已设置栅栏和警示","是否已拆除局部通风机","是否已清空工作面存煤"],"answer":[1],"explanation":"知识点：临时停工掘进工作面管理。停工地点必须设置栅栏、警示，防止人员误入。收回工具、拆除风机、清空存煤都不是停工检查的核心要求。"},{"id":75,"type":"single","stem":"井下安全检查发现某采煤工作面上下安全出口高度不足，正确的处置是","options":["要求作业人员弯腰通过即可","要求立即停止作业并整改","要求加强支护后继续生产","要求设置警示标志后观察"],"answer":[1],"explanation":"知识点：安全出口尺寸要求。安全出口高度不足影响人员撤离和救援，必须停止作业整改。弯腰通过、加强支护、设警示后观察都不能消除出口高度不足的隐患。"},{"id":76,"type":"multi","stem":"煤矿井下安全检查中，判定局部通风机实现风电闭锁功能应满足的条件包括","options":["风机停止运转时能自动切断工作面电源","工作面电源恢复前风机必须先启动","风机启动后工作面电源延时恢复","闭锁装置动作后需人工复位才能送电"],"answer":[0,1],"explanation":"知识点：风电闭锁功能要求。风电闭锁的核心是停风即停电、送电先送风，因此停风自动切断工作面电源、电源恢复前风机先启动是正确条件。风机启动后延时恢复电源是常见误记；闭锁动作后人工复位不是风电闭锁的必要条件。"},{"id":77,"type":"single","stem":"井下安全检查发现某处密闭墙前有积水且墙面渗水，检查人员应重点判断的是","options":["密闭墙墙体厚度是否达标","密闭墙内水位是否持续上升","密闭墙前是否设置排水沟","密闭墙附近是否存放材料"],"answer":[1],"explanation":"知识点：密闭墙检查。密闭墙前积水渗水可能反映采空区涌水或水位变化，重点判断墙内水位是否持续上升，以防溃水。墙体厚度、排水沟、材料存放不是此处最关键的判断内容。"},{"id":78,"type":"single","stem":"煤矿井下安全检查中，对使用中的主要通风机进行检查时，判定其是否实现双回路供电应查看","options":["两回路是否来自同一变电所","两回路是否分别来自不同电源","两回路导线截面是否一致","两回路是否共用同一开关柜"],"answer":[1],"explanation":"知识点：主要通风机双回路供电要求。双回路应来自不同电源，保证一路故障时另一路可用。同一变电所、共用开关柜都不满足独立供电要求；导线截面一致不是判定双回路的关键。"},{"id":79,"type":"single","stem":"井下安全检查发现某掘进工作面风筒末端距工作面距离超过规定，正确的处置是","options":["要求增加风筒长度即可","要求立即停止作业并整改","要求提高风机风量后继续","要求作业人员佩戴防尘口罩"],"answer":[1],"explanation":"知识点：风筒末端距工作面距离要求。距离超限会导致工作面风量不足、瓦斯积聚，必须停止作业整改。加长风筒、提高风量、戴防尘口罩都不能解决风筒距离超限带来的安全问题。"},{"id":80,"type":"single","stem":"井下巷道维修时发现顶板出现新增裂缝且伴有淋水加大，安全检查工首先应当组织人员做的是","options":["撤出受影响区域人员并设置警戒","用木料对裂缝处进行临时支护","继续观察裂缝变化并记录数据","安排人员清理裂缝下方浮矸"],"answer":[0],"explanation":"知识点：顶板来压预兆的应急处置。裂缝新增并淋水加大是顶板来压的明显预兆，首先应撤人设警戒，防止冒顶伤人；B项未撤人先支护，人员仍在危险区作业；C项继续观察会把人员留在危险区；D项清理浮矸同样使人处于危险顶板下。"},{"id":81,"type":"single","stem":"瓦斯检查工在采煤工作面回风隅角检测到瓦斯浓度达到1.2%，安全检查工正确的处置是","options":["责令停止工作、撤人并切断电源","要求加强通风后继续作业","让班长安排人员洒水降尘","记录数据后等下一班处理"],"answer":[0],"explanation":"知识点：采掘工作面瓦斯超限处置。回风隅角瓦斯达到1.2%已超限，必须停止工作、撤出人员、切断电源；B项通风不能替代撤人，且超限时继续作业违规；C项洒水降尘与瓦斯超限无关；D项拖延处理会扩大风险。"},{"id":82,"type":"single","stem":"煤矿井下爆破作业执行‘一炮三检’制度时，检查瓦斯的三个时间节点是","options":["装药前、放炮前、放炮后","打眼前、装药前、放炮后","装药前、联线前、放炮前","打眼前、联线前、放炮后"],"answer":[0],"explanation":"知识点：一炮三检的节点。规程要求装药前、放炮前、放炮后三次检查瓦斯；B项把联线前误当节点且缺放炮前；C项缺放炮后；D项节点错位且缺放炮前。"},{"id":83,"type":"single","stem":"安全检查工在掘进工作面发现局部通风机风筒末端距工作面距离过大，正确的判断是","options":["属于隐患，应责令整改后方可作业","属于正常现象，不影响通风","只要风机运转就无问题","由班长决定是否处理"],"answer":[0],"explanation":"知识点：局部通风管理。风筒末端距工作面距离超限会造成工作面风量不足、瓦斯积聚，属隐患必须整改；B项忽视了有效射程要求；C项风机运转不等于工作面风量达标；D项隐患整改不能由班长随意决定。"},{"id":84,"type":"single","stem":"井下某处电缆与风管、水管同侧敷设时，安全检查工应重点核查的敷设顺序是","options":["电缆应敷设在风管、水管上方并保持规定间距","电缆应敷设在风管、水管下方并保持规定间距","电缆与风管、水管紧贴敷设以便固定","电缆应穿过风管、水管之间敷设"],"answer":[0],"explanation":"知识点：井下管线敷设要求。电缆应敷设在风管、水管上方并保持规定间距，防止管路漏水淋湿电缆；B项下方敷设易受漏水影响；C项紧贴敷设不利于检修且易受损；D项穿越管路之间无法保证间距。"},{"id":85,"type":"single","stem":"井下电气设备停电检修时，安全检查工确认已执行的安全措施中，最关键的是","options":["验电、放电并悬挂‘有人工作，禁止送电’牌","断开开关后安排专人看管开关","断开开关后测量设备绝缘电阻","断开开关后清理设备周围浮煤"],"answer":[0],"explanation":"知识点：停送电安全措施。停电检修必须验电、放电、挂牌并闭锁，防止误送电；B项只看管不验电放电不完整；C项测绝缘不能替代验电放电和挂牌；D项清理浮煤与防误送电无关。"},{"id":86,"type":"single","stem":"煤矿井下发生火灾时，位于火源进风侧的人员正确的撤离方向是","options":["迎风撤出，逆着风流方向撤到安全地点","顺风撤出，顺着风流方向尽快远离火源","就近进入躲避硐室等待救援","原地不动等待救护队到来"],"answer":[0],"explanation":"知识点：火灾时人员撤离原则。火源进风侧人员应迎风撤出，避免被烟雾和有害气体侵袭；B项顺风撤离会进入烟流；C项躲避硐室适用于无法撤离时，首选仍是有条件撤离；D项原地不动会丧失撤离时机。"},{"id":87,"type":"single","stem":"安全检查工在检查采煤机内喷雾时，发现喷嘴堵塞数量超过半数，正确的处置意见是","options":["责令停机处理喷雾后方可继续作业","要求司机边作业边逐个疏通喷嘴","降低割煤速度以减少粉尘","等检修班再统一处理喷嘴"],"answer":[0],"explanation":"知识点：采煤机喷雾降尘要求。内喷雾失效会造成粉尘超标和截齿火花引燃风险，必须停机处理后作业；B项边作业边处理无法保证降尘；C项降速不能替代喷雾；D项拖延处理使隐患持续存在。"},{"id":88,"type":"single","stem":"井下使用中的主要通风机因故停止运转，安全检查工应首先督促执行的操作是","options":["立即通知撤出井下人员并打开井口防爆门","安排电工立即抢修主要通风机","通知井下人员原地等待恢复通风","安排人员检查井下瓦斯后再决定"],"answer":[0],"explanation":"知识点：主要通风机停风处置。停风后必须立即撤人并打开防爆门利用自然通风，防止瓦斯积聚；B项抢修同时未撤人；C项原地等待会使人员处于瓦斯积聚风险中；D项先检查瓦斯延误撤人时机。"},{"id":89,"type":"multi","stem":"安全检查工在井下发现下列哪些情形时，应当责令停止作业并撤出人员","options":["采掘工作面瓦斯浓度超过规定限值","巷道支护出现连续断梁折柱且顶板持续掉渣","局部通风机发生循环风且工作面风量不足","作业地点温度略高于规定但通风正常","工人未随身携带自救器但已登记"],"answer":[0,1,2],"explanation":"知识点：重大隐患停产撤人情形。瓦斯超限、支护严重失效持续掉渣、循环风导致风量不足均属必须停产撤人的重大隐患；D项温度略高且通风正常可通过调整解决，不构成停产撤人条件；E项未带自救器应纠正补带，不属撤人情形。"},{"id":90,"type":"single","stem":"井下安全检查中发现掘进工作面局部通风机风筒末端距迎头超过作业规程规定距离，检查人员的正确处置是","options":["记录后升井向调度室汇报","立即责令现场停止作业撤出人员","要求班长增加一节风筒后继续施工","在检查手册上标注下次复查"],"answer":[1],"explanation":"知识点：局部通风机风筒末端距迎头距离超限属于重大隐患，必须立即停止作业撤人。正确项对：超限会造成迎头风量不足、瓦斯积聚，必须立即停止作业撤出人员。干扰项错在：记录升井汇报延误处置；增加风筒后继续施工需先测量瓦斯并确认风量；仅标注复查不能消除当前危险。"},{"id":91,"type":"single","stem":"煤矿安全检查作业人员进入采煤工作面检查时，发现上隅角瓦斯浓度达到1.5%，此时应首先采取的措施是","options":["切断工作面所有非本安型电气设备电源","通知瓦检员继续观测等待浓度下降","要求采煤机停机继续割煤观察","打开上隅角附近风窗增大风量"],"answer":[0],"explanation":"知识点：采煤工作面上隅角瓦斯浓度达到1.0%即须停止工作、撤人、切断非本安型电源。正确项对：1.5%已超限，首要措施是切断非本安型电气设备电源防止引爆。干扰项错在：等待浓度下降是被动做法；继续割煤会加大瓦斯涌出和火源风险；仅打开风窗不解决超限处置的即时性。"},{"id":92,"type":"single","stem":"煤矿井下安全检查中测量巷道风速，测风站应选择在巷道断面规整、无分叉、无拐弯且前后有一定直线段的位置，其前后直线段长度一般要求为","options":["前后各不小于10m","前后各不小于15m","前后各不小于20m","前后各不小于5m"],"answer":[0],"explanation":"知识点：测风站应设在断面规整、无分叉、无拐弯、无杂物堆积的直线段，前后各不小于10m。正确项对：10m直线段可保证风流稳定、测值代表性好。干扰项错在：15m和20m虽更保守但非规程要求的一般值；5m过短风流不稳，测值偏差大。"},{"id":93,"type":"single","stem":"井下安全检查发现某处电缆与压风管、供水管同侧敷设且相互缠绕，检查人员判定该敷设方式不符合要求，主要理由是","options":["电缆与管路同侧敷设会影响管路检修","电缆与管路缠绕易受管路漏气漏水影响绝缘","电缆与管路同侧会增大巷道断面占用","电缆与管路缠绕会降低供风供水压力"],"answer":[1],"explanation":"知识点：电缆不应与管路特别是压风、供水管路同侧缠绕，防止管路漏气漏水导致电缆绝缘受潮或短路。正确项对：缠绕后管路漏气漏水直接作用于电缆，绝缘受损。干扰项错在：影响检修、占用断面、降低压力均非判定该敷设方式违规的核心理由。"},{"id":94,"type":"single","stem":"煤矿安全检查作业人员检查井下电气设备时，发现一台开关的接地线用铝芯线代替铜芯线，且截面明显偏小，正确判断是","options":["接地线材质和截面均不符合要求，须立即整改","只要接地电阻合格，材质可以替代","铝芯线比铜芯线轻，便于悬挂可以接受","截面偏小但材质更换后即可继续使用"],"answer":[0],"explanation":"知识点：井下接地线须用铜芯线并满足截面要求，铝芯线易氧化断裂、截面不足影响接地可靠性。正确项对：材质和截面都不符合，须立即整改。干扰项错在：接地电阻合格不能掩盖材质截面违规；轻便不是选材依据；仅换材质不解决截面问题。"},{"id":95,"type":"single","stem":"井下安全检查中发现爆破作业后等待时间未到，班长即安排人员进入工作面，检查人员应认定为","options":["违章指挥，须立即制止并撤出人员","班组自主安排，检查人员可事后记录","缩短等待时间的临时措施，可默认","爆破效果良好时的合理调整"],"answer":[0],"explanation":"知识点：爆破后须等足规定等待时间并通风排烟、检查确认后方可进入。正确项对：未到等待时间进入属违章指挥，须立即制止撤人。干扰项错在：班组自主不能违反规定；临时措施不能突破安全底线；爆破效果与等待时间无关。"},{"id":96,"type":"single","stem":"煤矿安全检查作业中，判断采掘工作面是否属于煤与瓦斯突出危险区域，最直接的依据是","options":["工作面瓦斯浓度是否经常超限","是否位于突出煤层及突出危险区划范围内","煤层厚度是否超过规定值","工作面是否采用放炮落煤"],"answer":[1],"explanation":"知识点：煤与瓦斯突出危险区域依据突出煤层和突出危险区划确定。正确项对：是否位于突出煤层及危险区划范围内是直接依据。干扰项错在：瓦斯超限是现象不是划定依据；煤层厚度、落煤方式与突出危险性划定无直接对应关系。"},{"id":97,"type":"single","stem":"井下安全检查发现某巷道维修地点未设置临时支护，作业人员站在空顶下作业，检查人员应","options":["要求先架设临时支护再作业","要求作业人员戴好安全帽后继续","要求加快维修速度尽快通过","要求安排专人观察顶板后继续"],"answer":[0],"explanation":"知识点：巷道维修空顶作业必须先用临时支护控制顶板。正确项对：先架设临时支护再作业是消除空顶隐患的根本措施。干扰项错在：戴安全帽、加快速度、专人观察都不能替代临时支护对顶板的控制。"},{"id":98,"type":"single","stem":"煤矿安全检查作业人员对井下消防器材进行检查时，发现灭火器压力表指针在红区，正确处置是","options":["记录后通知使用单位尽快更换或充装","摇动灭火器后继续留用","只要瓶体无锈蚀即可继续使用","将灭火器倒置存放待压力回升"],"answer":[0],"explanation":"知识点：灭火器压力表指针在红区表示压力不足，须更换或充装。正确项对：记录并通知使用单位更换或充装可保证器材有效。干扰项错在：摇动不能恢复压力；瓶体无锈蚀不代表压力合格；倒置存放不能使压力回升。"},{"id":99,"type":"single","stem":"井下安全检查中发现带式输送机机头堆煤保护装置被拆除，检查人员判定该行为属于","options":["擅自拆除安全保护装置，须立即停止使用并追查","检修期间的临时措施，可允许","堆煤保护易误动作，拆除可提高效率","只要司机在岗观察即可替代保护"],"answer":[0],"explanation":"知识点：带式输送机堆煤保护等安全保护装置不得擅自拆除。正确项对：拆除保护装置属严重违章，须停止使用并追查。干扰项错在：检修临时措施也须履行审批并恢复；误动作应调整不能拆除；人工观察不能替代保护装置。"},{"id":100,"type":"single","stem":"煤矿井下安全检查中发现局部通风机风筒末端距掘进工作面超过作业规程规定距离，且风筒有破口漏风，检查人员应当首先采取的措施是","options":["记录隐患并当日汇总上报矿调度室","现场责令停止掘进作业撤出人员","协助当班班长立即修补风筒破口","测量迎头瓦斯浓度后再作决定"],"answer":[1],"explanation":"知识点：局部通风管理与重大隐患处置。《煤矿安全规程》要求风筒末端距迎头距离符合作业规程规定，风筒破口漏风会导致迎头风量不足，属重大隐患。正确项：风量不足可能造成瓦斯积聚，必须立即停止作业撤人。错误项：仅记录上报延误了撤人时机；修补风筒需在确保安全前提下由专人进行，非检查人员首责；测瓦斯虽重要但不能替代先撤人的处置原则。"},{"id":101,"type":"single","stem":"煤矿安全检查工在采煤工作面回风隅角检查时，发现瓦斯浓度达到1.2%且仍有上升趋势，正确的处置顺序是","options":["停止工作面作业、切断电源、撤出人员、汇报调度","加大风量稀释后继续观察瓦斯变化情况","通知瓦检员加强检测并做好记录备查","撤出人员后由班组长组织查明瓦斯来源"],"answer":[0],"explanation":"知识点：瓦斯超限应急处置程序。《煤矿安全规程》规定采掘工作面回风隅角瓦斯浓度超过1.0%时必须停止作业、切断电源、撤出人员。正确项：先停机停电撤人再汇报，顺序不可颠倒。错误项：加大风量不能替代撤人停电，且可能扰动积聚瓦斯；仅通知检测不处置属失职；查明来源应在撤人停电之后而非之前。"},{"id":102,"type":"single","stem":"煤矿安全检查作业人员进入井下检查前，对随身携带的便携式甲烷检测报警仪应当进行的确认项目是","options":["外观完好并在校验有效期内且电量充足","显示数值与光学瓦检仪读数比对一致","报警声级不低于70分贝且灯光正常","机身编号与台账登记编号相互对应"],"answer":[0],"explanation":"知识点：入井仪器装备确认要求。正确项：便携仪必须外观完好、校验有效、电量充足才能保证检测准确。错误项：与光学瓦检仪比对属定期校对工作，不是每次入井前必做；声级和编号是辅助管理项，不是入井前确认的核心条件。"},{"id":103,"type":"single","stem":"井下检查时发现某掘进巷道采用锚杆支护的顶板出现一根锚杆托盘松动、周围岩面有轻微离层，检查人员的正确处置是","options":["现场标记并督促当班人员及时紧固处理","判定为重大隐患责令立即停止全矿作业","记录后待下次检查时复查是否发展","通知施工队自行安排时间整改即可"],"answer":[0],"explanation":"知识点：顶板支护隐患现场处置。正确项：锚杆托盘松动属可现场整改的一般隐患，标记并督促当班处理可及时消除。错误项：单根锚杆松动不构成全矿停产的重大隐患；待下次复查会延误处理；仅通知自行安排缺乏跟踪督促，可能漏改。"},{"id":104,"type":"single","stem":"煤矿安全检查中发现某采区变电所内检漏继电器被人为甩掉不用，检查人员正确的判断是","options":["属重大隐患须立即停止该采区供电并汇报","属一般隐患可责令当班电工恢复后继续生产","属设备故障应通知机电科安排检修计划","属管理问题应记录并纳入月度考核处理"],"answer":[0],"explanation":"知识点：电气安全保护装置管理。甩掉检漏继电器会使漏电保护失效，可能引发触电或引爆瓦斯，属重大隐患。正确项：必须立即停止该采区供电并汇报。错误项：恢复后继续生产忽视了停电处置前提；按一般故障走检修计划降格处理；仅纳入考核不解决现场危险状态。"},{"id":105,"type":"single","stem":"井下爆破作业安全检查时，发现爆破工在装药前未按规定检查瓦斯和煤尘浓度即开始装药，检查人员应当","options":["立即制止装药并要求先检测合格后再作业","要求爆破工补测一次浓度并记录在案","允许装药但须在放炮前补做检测","通知班组长到场监督后续爆破过程"],"answer":[0],"explanation":"知识点：爆破前安全条件确认。装药前必须检查瓦斯和煤尘，超限严禁装药。正确项：立即制止并待检测合格后方可作业。错误项：补测记录不能挽回已违规装药的风险；允许装药再补测违反程序；通知监督不能替代先制止违规行为。"},{"id":106,"type":"single","stem":"煤矿安全检查工在检查主要通风机运行情况时，发现风机轴承温度超过规定值但仍在运转，正确的处置是","options":["立即报告矿调度并按应急预案采取措施","记录温度数值待停机检修时一并处理","通知司机加强观察并定时记录温度","降低风机转速以缓解轴承温升问题"],"answer":[0],"explanation":"知识点：主要通风机异常处置。主要通风机承担全矿通风，轴承超温可能造成停机停风。正确项：立即报告调度并启动应急措施。错误项：待检修处理会延误可能导致停风的隐患；仅观察记录不处置风险大；擅自降速可能造成井下风量不足。"},{"id":107,"type":"single","stem":"井下安全检查发现某处永久密闭墙前设有栅栏但未悬挂瓦斯检查牌板和说明牌，检查人员应认定为","options":["通风设施管理不完善的隐患需限期整改","密闭墙本身不合格须立即拆除重建","重大隐患须立即停止全矿采掘作业","正常情况无需设置牌板管理"],"answer":[0],"explanation":"知识点：通风设施检查标准。永久密闭墙前应设栅栏并悬挂检查牌板和说明牌，缺失属管理不完善的一般隐患。正确项：限期整改即可。错误项：密闭墙本身未必不合格，无需拆除重建；不构成全矿停产的重大隐患；牌板是规定要求，不能不设。"},{"id":108,"type":"single","stem":"煤矿安全检查工在井下发现作业人员携带烟草和点火物品准备入井，正确的处置是","options":["当场制止并收缴物品同时报告有关部门","批评教育后允许其将物品存放在井口","要求其将物品交给同班工友代为保管","记录姓名后允许入井但事后罚款处理"],"answer":[0],"explanation":"知识点：入井违禁物品管理。烟草和点火物品严禁入井。正确项：当场制止、收缴并报告。错误项：允许存放井口仍存在被带入风险；交工友保管不能消除隐患；事后罚款不能替代现场制止。"},{"id":109,"type":"single","stem":"煤矿安全检查作业中，检查人员发现采煤工作面支柱初撑力普遍低于作业规程规定值，正确的处理方式是","options":["责令立即补液升柱并抽查合格后方可作业","记录数据后要求下一班统一整改处理","通知支护班组自行安排时间补液升柱","判定为重大隐患停止全矿采掘作业"],"answer":[0],"explanation":"知识点：采煤工作面支护质量检查。初撑力不足易导致顶板事故，须立即补液升柱。正确项：责令立即处理并抽查合格后作业。错误项：推到下一班延误处理；自行安排缺乏监督；普遍偏低多为一般隐患，未达全矿停产条件。"},{"id":110,"type":"single","stem":"煤矿安全检查工在检查井下消防器材时，发现某机电硐室灭火器压力指针处于欠压区，正确的处置是","options":["责令使用单位立即更换合格灭火器","记录后待灭火器年检时统一充装","将灭火器倒置摇匀后继续留用观察","通知机电科采购新灭火器后更换"],"answer":[0],"explanation":"知识点：消防器材完好性检查。灭火器欠压表示失效，不能保证灭火效果。正确项：立即更换合格灭火器。错误项：待年检延误隐患整改；倒置摇匀不能恢复压力；等采购到位期间现场处于无有效灭火器状态。"},{"id":111,"type":"single","stem":"井下安全检查中发现局部通风机风筒末端距掘进工作面距离超过作业规程规定，但工作面瓦斯浓度仅0.6%，正确处置是","options":["记录后交班时汇报，本班继续作业","立即停止掘进作业，撤出人员并督促整改","要求班组长加强瓦斯监测后可继续作业","将风筒末端简单接长一节后恢复作业"],"answer":[1],"explanation":"知识点：风筒末端距工作面距离超限属于重大隐患，可能导致瓦斯积聚。正确项对：必须立即停产撤人并整改。错误项一：交班汇报不能消除当班风险，隐患未整改不得作业。错误项二：瓦斯监测不能替代风筒到位要求。错误项三：简单接长未必符合规程要求，且未经验收不得恢复。"},{"id":112,"type":"single","stem":"检查采煤工作面液压支架时，发现个别支架初撑力低于规程要求，支架未出现明显下沉，安全检查人员的正确做法是","options":["视为正常现象，待周期来压时再处理","要求立即补液升架并查明原因","让采煤机先通过该区域再处理","记录后由下一班统一调整"],"answer":[1],"explanation":"知识点：液压支架初撑力不足是顶板事故重要诱因。正确项对：必须立即补液升架并查明原因。错误项一：等待来压会错过处理时机。错误项二：采煤机通过会扰动顶板，风险更大。错误项三：拖延到下一班可能发生漏顶。"},{"id":113,"type":"single","stem":"检查井下电气设备时，发现一台开关的接地线连接螺栓松动但接地线未脱落，正确处置是","options":["用扳手现场紧固后即可继续使用","立即停止该设备运行并督促整改","观察一段时间确认无发热后再处理","通知电工在检修班统一紧固"],"answer":[1],"explanation":"知识点：接地保护是防止触电的关键，连接松动会导致接地电阻增大。正确项对：必须立即停运整改。错误项一：现场紧固未经测试不能确认接地电阻合格。错误项三：观察无法替代整改，松动本身即隐患。错误项四：拖延到检修班期间设备带隐患运行。"},{"id":114,"type":"single","stem":"井下发生瓦斯超限报警后，安全检查员首先应当做的是","options":["通知电工检查瓦斯传感器是否故障","责令现场人员停止作业并撤至安全地点","加大风量稀释瓦斯后继续作业","记录超限数据等待通风部门分析"],"answer":[1],"explanation":"知识点：瓦斯超限必须立即停产撤人。正确项对：撤人是首要措施。错误项一：先查传感器会延误撤人时机。错误项三：加大风量不能替代撤人，且可能扰动瓦斯。错误项四：记录分析是后续工作，不能先于撤人。"},{"id":115,"type":"single","stem":"检查井下爆破作业时，发现爆破工未按规定使用发爆器钥匙而用其他工具代替，正确判断是","options":["只要起爆成功即可视为合格","属于严重违章，必须立即制止","属于一般问题，记录后交班处理","要求爆破工下次注意即可继续作业"],"answer":[1],"explanation":"知识点：发爆器钥匙管理是爆破安全的关键环节，替代工具可能导致误爆。正确项对：必须立即制止。错误项一：结果成功不能掩盖程序违章。错误项三：交班处理不能消除当次风险。错误项四：口头提醒不能替代制止和整改。"},{"id":116,"type":"single","stem":"井下安全检查中，发现一处在用巷道净高低于规程要求但平时无人通行，正确处置是","options":["因无人通行可暂不处理","设置警示并督促限期整改","待巷道变形稳定后再处理","仅记录在检查台账中"],"answer":[1],"explanation":"知识点：巷道净高不足会影响通风、运输和行人安全，即使暂无人通行也属隐患。正确项对：应设置警示并督促整改。错误项一：无人通行不能作为不处理理由。错误项三：变形稳定时间不确定，不能等待。错误项四：仅记录不整改不能消除隐患。"},{"id":117,"type":"single","stem":"检查井下消防器材时，发现灭火器压力表指针在绿区但已超过有效期，正确判断是","options":["压力正常即可继续使用","属于失效器材，应督促更换","可移至备用地点继续存放","补充灭火药剂后继续使用"],"answer":[1],"explanation":"知识点：灭火器有效期是器材完好的必要条件，超期即失效。正确项对：应督促更换。错误项一：压力正常不代表药剂有效。错误项三：移至备用地点仍是失效器材。错误项四：现场补充药剂不符合器材管理要求。"},{"id":118,"type":"single","stem":"井下安全检查员在采煤工作面发现顶板出现新裂隙且伴有淋水增大，正确处置是","options":["要求加强支护并撤出受威胁人员","继续观察一个循环后再决定","通知采煤机司机加快回采速度","在裂隙处打设临时点柱后继续作业"],"answer":[0],"explanation":"知识点：顶板新裂隙伴淋水增大是冒顶和突水前兆。正确项对：必须加强支护并撤人。错误项一：观察一个循环可能错过撤离时机。错误项三：加快回采会加剧顶板扰动。错误项四：临时点柱不能替代系统支护和撤人。"},{"id":119,"type":"single","stem":"井下安全检查中发现某掘进工作面同时进行打眼和装药作业，正确处置是","options":["只要不在同一位置即可同时进行","立即制止，装药时严禁其他作业","要求打眼人员佩戴耳塞后继续","由班组长现场协调后继续作业"],"answer":[1],"explanation":"知识点：装药作业期间严禁其他无关作业，防止意外起爆。正确项对：必须立即制止。错误项一：同一工作面不同位置仍存在相互影响。错误项三：佩戴耳塞不能解决爆破安全冲突。错误项四：现场协调不能改变规程禁止性要求。"},{"id":120,"type":"single","stem":"检查井下运输巷道时，发现矿车在坡度大于规程规定的轨道上停放且未设阻车装置，正确处置是","options":["要求立即设置阻车装置并查明原因","通知司机尽快将矿车开走","在矿车下方垫石块后继续停放","记录后由运输队自行处理"],"answer":[0],"explanation":"知识点：斜坡停放矿车必须设阻车装置，防止跑车。正确项对：应立即设阻车装置并查因。错误项一：开走不能替代当前防跑车措施。错误项三：垫石块不符合阻车装置要求。错误项四：拖延处理可能发生跑车事故。"},{"id":121,"type":"multi","stem":"井下安全检查员在采掘工作面检查时，发现下列哪些情形应当立即责令停止作业并撤出人员","options":["瓦斯浓度超过规程规定且继续上升","顶板出现明显离层且伴有响声","工作面温度略高于正常值2摄氏度","局部通风机突然停止运转","巷道内粉尘浓度略高于正常值"],"answer":[0,1,3],"explanation":"知识点：瓦斯超限上升、顶板离层响动、局扇停风都是立即撤人的重大隐患。正确项一：瓦斯超限上升有爆炸风险。正确项二：顶板离层响声是冒顶前兆。正确项四：局扇停风会导致瓦斯积聚。错误项三：温度略高不构成立即撤人条件。错误项五：粉尘略高应整改但不属立即撤人情形。"},{"id":122,"type":"single","stem":"井下巷道维修地点进行安全检查时，发现顶板有离层响声且已架设临时支护，检查工首先应当采取的措施是","options":["撤出该地点所有人员并设置警戒","继续观察离层变化并记录时间","组织人员对离层部位补打锚杆","用长柄工具敲帮问顶后继续作业"],"answer":[0],"explanation":"知识点：顶板离层伴有响声是冒顶前兆，必须先撤人设警。撤人设警可避免人员伤亡，是首要措施；继续观察会延误撤离时机；补打锚杆需在人员安全前提下进行，不能作为首选；敲帮问顶适用于无明显冒顶征兆时，响声离层已属危险征兆。"},{"id":123,"type":"single","stem":"煤矿安全检查工在采煤工作面检查甲烷传感器时，发现其显示值与光学甲烷检测仪实测值相差较大，正确处置是","options":["以光学检测仪读数为准并立即汇报调度","以传感器读数为准继续生产并记录偏差","先调校传感器使其与检测仪一致再汇报","两读数取平均值作为该地点实际浓度"],"answer":[0],"explanation":"知识点：传感器与实测偏差大说明传感器可能失准，应人工实测为准并汇报。人工实测优先可及时掌握真实浓度；以传感器为准会掩盖超限风险；擅自调校会破坏证据且可能掩盖故障；取平均值无依据且会低估真实浓度。"},{"id":124,"type":"single","stem":"掘进工作面局部通风机因故停止运转，恢复通风前检查工必须确认的事项是","options":["瓦斯浓度和二氧化碳浓度符合规定","局部通风机供电是否已切换备用","风筒吊挂是否平直牢固","工作面是否有人员在作业"],"answer":[0],"explanation":"知识点：停风后恢复通风前必须先检查瓦斯和二氧化碳浓度。浓度合格才可启动风机送风；供电切换、风筒吊挂、人员情况均非恢复通风的前置安全条件，浓度超限时启动风机可能造成事故。"},{"id":125,"type":"single","stem":"检查井下电气设备时，发现某台开关的接地线连接螺栓松动，正确的处置方式是","options":["立即停止该设备运行并重新紧固接地线","用铜丝临时缠绕固定后继续使用","记录在案待检修班统一处理","降低该设备负荷后继续运行"],"answer":[0],"explanation":"知识点：接地线松动会使保护失效，必须停运处理。停运并紧固可恢复保护功能；铜丝临时缠绕接触不可靠且属违规；带病运行期间可能发生漏电事故；降负荷不能解决接地失效问题。"},{"id":126,"type":"single","stem":"在倾斜巷道检查轨道运输时，发现跑车防护装置挡车栏处于常开状态，检查工应当","options":["责令停止运输并恢复挡车栏正常闭锁","提醒司机下放车辆时注意控制速度","在挡车栏处悬挂警示牌后允许通行","记录问题并要求当班班长口头交代"],"answer":[0],"explanation":"知识点：挡车栏常开使跑车防护失效，必须停止运输并恢复闭锁。停运恢复可防止跑车事故；仅提醒司机不能替代防护装置；挂警示牌不解决装置失效；口头交代无整改效果。"},{"id":127,"type":"single","stem":"井下检查时发现某处密闭墙前瓦斯浓度达到1.5%，检查工的正确做法是","options":["撤出附近人员并切断该区域电源后汇报","打开密闭墙通风稀释瓦斯浓度","在密闭墙前继续检测等待浓度下降","用风筒对准密闭墙前吹风降低浓度"],"answer":[0],"explanation":"知识点：密闭墙前瓦斯超限应按超限处置，撤人断电汇报。撤人断电可防止瓦斯爆炸；擅自打开密闭会释放大量有害气体；原地等待可能遇火源；吹风不能消除瓦斯来源且可能扩散。"},{"id":128,"type":"single","stem":"煤矿安全检查工对井下消防材料库进行检查时，重点应核对的内容是","options":["材料品种数量与台账是否相符且在有效期","库房照明是否采用矿用防爆灯具","库房地面是否平整无积水","消防材料摆放是否整齐美观"],"answer":[0],"explanation":"知识点：消防材料库检查核心是材料品种、数量、有效期与台账相符。账物相符且在有效期才能保证应急使用；照明、地面、摆放整齐属一般管理要求，不是重点核对内容。"},{"id":129,"type":"single","stem":"采煤工作面回风巷中甲烷传感器报警断电后，检查工首先应做的工作是","options":["查明超限原因并组织撤出受影响人员","立即复位传感器恢复供电生产","通知电工检查断电仪是否故障","记录报警时间后继续正常检查"],"answer":[0],"explanation":"知识点：瓦斯超限报警断电后应先查原因并撤人。查明原因撤人可防止事故扩大；复位恢复供电会在超限未消除时引发危险；先查断电仪会延误撤人；只记录不处置属失职。"},{"id":130,"type":"single","stem":"井下爆破作业前，安全检查工检查炮眼时发现炮眼内有岩粉未清除干净，正确处置是","options":["要求重新清孔后再装药","允许装药但减少装药量","允许装药并使用水炮泥封堵","要求加深炮眼后装药"],"answer":[0],"explanation":"知识点：炮眼内岩粉未清会影响爆破效果并可能引起拒爆。重新清孔可保证装药质量；减少药量不能消除岩粉影响；水炮泥封堵不解决孔内岩粉；加深炮眼无法清除原有岩粉。"},{"id":131,"type":"single","stem":"检查井下主要排水泵房时，发现工作水泵和备用水泵的电源来自同一回路，检查工应判定为","options":["不符合要求，备用泵应能独立供电","符合要求，只要水泵能正常运转","符合要求，两泵不会同时使用","不符合要求，但可在检修时整改"],"answer":[0],"explanation":"知识点：工作泵与备用泵应能独立供电，防止一处故障导致全部失效。同回路供电使备用泵失去备用意义；水泵能运转不代表供电可靠；认为不会同时使用是错误假设；发现即应整改而非拖延。"},{"id":132,"type":"single","stem":"井下采掘工作面检查中，发现职工在停风区域休息且该区域瓦斯浓度未检测，检查工应当","options":["立即令其撤出并检测瓦斯后汇报","允许其短时休息并补测瓦斯","令其佩戴自救器后继续休息","记录后交班时统一汇报处理"],"answer":[0],"explanation":"知识点：停风区域瓦斯情况不明，人员不得停留。立即撤出并检测可防止窒息或爆炸；允许休息会使人处于危险区域；佩戴自救器不能替代撤出和检测；交班汇报延误处置时机。"},{"id":133,"type":"single","stem":"煤矿井下安全检查中，发现局部通风机因故障停止运转，恢复通风前最应先做的工作是","options":["直接启动局部通风机恢复供风","检查瓦斯浓度并控制风流排放","安排人员进入独头巷查看情况","向矿调度室汇报后等待指令"],"answer":[1],"explanation":"知识点：停风后恢复通风的瓦斯管理程序。局部通风机停风后独头巷道可能积聚瓦斯，直接启动风机可能把高浓度瓦斯吹入电气设备处引发事故，必须先检查瓦斯并按措施控制排放。直接启动风机易造成瓦斯超限风流；进入独头巷查看属冒险行为；仅汇报等待而不检查瓦斯不能排除隐患。"},{"id":134,"type":"single","stem":"煤矿安全检查作业中，对采煤工作面支架初撑力进行抽检，正确做法是","options":["在支架移架后立即读取压力表数值","在支架移架后稳定一段时间再读取","在采煤机割煤时同步读取压力数值","在支架卸载降柱过程中读取数值"],"answer":[1],"explanation":"知识点：支架初撑力检测时机。初撑力是支架升起支撑顶板后达到的压力，需在移架升柱稳定后测读才准确。移架后立即读数因压力未稳定偏低；割煤时支架受扰动读数不准；卸载降柱过程压力正在下降，不能代表初撑力。"},{"id":135,"type":"single","stem":"井下安全检查发现某掘进工作面风筒末端距工作面距离超过规程允许值，正确的现场处置是","options":["记录后交班时再通知施工队","立即要求停止作业并接长风筒","自行把风筒末端向前拖动接长","测量风量后允许继续作业"],"answer":[1],"explanation":"知识点：掘进工作面风筒末端距工作面距离超标属重大隐患。风筒距工作面过远会造成工作面微风或无风，必须立即停止作业并接长风筒。记录后交班延误处置；自行拖动风筒可能损坏风筒且非检查人员职责；测风量不能替代距离要求。"},{"id":136,"type":"single","stem":"煤矿安全检查中，检查甲烷传感器悬挂位置时，采煤工作面上隅角传感器应悬挂在","options":["工作面回风巷距采空区10m处","上隅角切顶线处靠采空区侧","工作面上出口支架顶梁下方","回风巷内距工作面15m处"],"answer":[1],"explanation":"知识点：上隅角甲烷传感器悬挂位置要求。上隅角是采空区瓦斯涌出的集中点，传感器应悬挂在上隅角切顶线处靠采空区侧才能及时监测。回风巷距采空区10m处、上出口支架下方、回风巷距工作面15m处均偏离上隅角实际瓦斯涌出点。"},{"id":137,"type":"single","stem":"井下安全检查中，发现某处电气设备接地保护装置断开，正确的判断是","options":["设备仍可运行只是保护失效","属失爆隐患须立即停电处理","待检修班再恢复接地连接","接地断开不影响漏电保护"],"answer":[1],"explanation":"知识点：井下电气设备接地保护的作用与失爆判定。接地保护断开使漏电电流无法安全入地，属严重隐患，必须立即停电处理。设备继续运行会扩大触电和引爆风险；推迟到检修班违反立即处理原则；接地断开直接影响漏电保护动作可靠性。"},{"id":138,"type":"single","stem":"煤矿安全检查作业中，对斜巷提升运输检查发现跑车防护装置被吊起固定，正确处置是","options":["询问司机后允许继续提升","立即停止提升并恢复防护装置","记录后要求班后整改即可","在斜巷上下口增设警戒人员"],"answer":[1],"explanation":"知识点：斜巷跑车防护装置的作用。跑车防护装置被吊起固定后失去挡车功能，一旦发生跑车事故后果严重，必须立即停止提升并恢复。询问司机不能替代恢复装置；班后整改期间仍存在跑车风险；增设警戒人员不能阻挡跑车。"},{"id":139,"type":"single","stem":"井下安全检查发现某采煤工作面液压支架出现漏液且动作缓慢，正确的处置是","options":["继续使用并加强观察压力","停止使用并安排维修更换","降低泵站压力继续使用","临时用木料支设后继续作业"],"answer":[1],"explanation":"知识点：液压支架漏液对支护质量的影响。支架漏液会导致初撑力和工作阻力不足，不能有效支撑顶板，应停止使用并维修更换。继续使用或降泵压使用会削弱支护；用木料支设不能替代支架额定支护能力。"},{"id":140,"type":"single","stem":"煤矿安全检查中，发现井下某处电缆与风管、水管同侧敷设且电缆位于管路上方，正确的判定是","options":["符合要求电缆应在管路上方","不符合要求电缆应在管路下方","符合要求只要间距达标即可","不符合要求电缆应穿管保护"],"answer":[0],"explanation":"知识点：井下电缆与管路的敷设位置要求。电缆敷设在风管、水管上方可避免管路漏水淋湿电缆，符合规程要求。认为应在下方会受管路漏水影响；间距达标不能改变上下位置关系；穿管保护不是此处必需措施。"},{"id":141,"type":"single","stem":"井下安全检查发现某处盲巷未及时封闭，正确的处置是","options":["设置栅栏并挂警示牌即可","立即停止作业并按规定封闭","安排人员进入检测瓦斯浓度","在盲巷口设置临时挡风墙"],"answer":[1],"explanation":"知识点：盲巷管理要求。盲巷易积聚瓦斯且人员误入危险，发现未封闭盲巷应立即停止作业并按规定封闭。仅设栅栏警示不能消除瓦斯隐患；人员进入检测属冒险；临时挡风墙不能替代永久封闭。"},{"id":142,"type":"single","stem":"煤矿安全检查作业中，对爆破作业检查发现炮眼封泥长度不足，正确的处置是","options":["允许放炮但减少装药量","立即制止并按规定补足封泥","记录后交班时通知爆破员","改用炮泥袋替代封泥封孔"],"answer":[1],"explanation":"知识点：炮眼封泥长度的作用。封泥不足会导致爆破火焰喷出、瓦斯煤尘爆炸风险，必须立即制止并按规定补足。减少装药不能替代封泥要求；交班通知延误处置；炮泥袋不能替代规定封泥长度和材质。"},{"id":143,"type":"single","stem":"井下安全检查发现某掘进工作面同时存在空顶作业和风筒距工作面超标，检查人员应优先","options":["先记录后汇报等待处理","立即停止作业撤出人员","先接长风筒再处理空顶","先支护空顶再测风量"],"answer":[1],"explanation":"知识点：重大隐患并存时的应急处置原则。空顶作业和风筒超标均属重大隐患，可能随时引发冒顶和瓦斯事故，首要措施是立即停止作业撤出人员。先记录、先接风筒、先支护均把人员置于危险中，违反先撤人原则。"},{"id":144,"type":"single","stem":"井下检查采煤工作面回风隅角瓦斯时，便携式甲烷检测仪应悬挂在距顶板不大于多少、距巷帮不小于多少的位置读数","options":["距顶板300mm、距巷帮200mm","距顶板200mm、距巷帮300mm","距顶板500mm、距巷帮200mm","距顶板200mm、距巷帮500mm"],"answer":[0],"explanation":"知识点是瓦斯检测取点位置。正确项符合回风隅角检测的常规要求；错项将顶板与巷帮距离对调或改变数值，属于记忆混淆。"},{"id":145,"type":"single","stem":"检查井下局部通风机风筒时，发现风筒末端距工作面超过规程允许距离，现场应优先采取的措施是","options":["继续作业并通知班组长","延长风筒并恢复正常供风","加大风机功率但不接风筒","暂停该处检查记录后离开"],"answer":[1],"explanation":"知识点是局部通风风筒末端距离超限的处置。正确项是消除隐患的直接措施；错项继续作业会致瓦斯积聚，只加大功率不接风筒不解决末端送风，记录后离开未消除隐患。"},{"id":146,"type":"single","stem":"在井下检查发现巷道顶板出现新裂缝且伴有掉渣，安全检查工首先应做的是","options":["用长柄工具敲帮问顶并撤出下方人员","立即组织人员架棚支护","拍照记录后继续向前检查","通知采煤机司机加快通过"],"answer":[0],"explanation":"知识点是顶板异常时的现场处置顺序。正确项先撤人并敲帮问顶；错项未撤人先支护、先记录、加快通过均违反先撤人后处理原则。"},{"id":147,"type":"single","stem":"检查井下电气设备时，发现隔爆外壳结合面有油漆覆盖，正确的判断是该设备","options":["仍可继续使用但需记录","失去隔爆性能不得送电","只需擦拭外壳即可送电","降低负荷后可继续运行"],"answer":[1],"explanation":"知识点是隔爆结合面性能要求。结合面被油漆覆盖会增大间隙影响隔爆，正确项判定失爆；错项继续使用、仅擦拭、降负荷均未消除失爆。"},{"id":148,"type":"single","stem":"矿井主要通风机停止运转后，井下安全检查工在恢复通风前应首先检查的是","options":["各工作面瓦斯和二氧化碳浓度","井下运输设备是否完好","巷道支护是否变形","人员是否全部升井"],"answer":[0],"explanation":"知识点是恢复通风前的气体检查。正确项先查瓦斯与二氧化碳；错项设备、支护、人员情况不是恢复通风前首要气体条件。"},{"id":149,"type":"single","stem":"检查井下爆破作业时，发现炮眼封泥长度不足，安全检查工应当","options":["允许放炮但减少装药量","制止放炮并要求补足封泥","允许放炮但加大警戒距离","允许放炮并记录后补泥"],"answer":[1],"explanation":"知识点是爆破封泥要求。封泥不足易致火焰喷出引发事故，正确项为制止并补足；错项允许放炮的三种变通均未消除隐患。"},{"id":150,"type":"single","stem":"井下检查发现某处一氧化碳浓度持续升高且伴有焦油味，最可能的隐患是","options":["采空区煤炭自燃","局部通风机停转","电缆过载发热","锚杆托盘松动"],"answer":[0],"explanation":"知识点是自燃火灾征兆判断。一氧化碳升高伴焦油味为自燃典型标志；错项通风机停转主要致瓦斯升高，电缆过载多有焦糊味但无持续一氧化碳，锚杆松动与气体无关。"},{"id":151,"type":"single","stem":"在井下检查斜巷运输时，发现跑车防护装置被吊起固定，正确的处置是","options":["要求立即恢复防护装置并停止运输","允许运输但限速运行","允许运输但设专人监护","记录后交班时再处理"],"answer":[0],"explanation":"知识点是斜巷跑车防护装置管理。防护装置被固定失效必须立即恢复并停运；错项限速、监护、交班处理均未消除跑车风险。"},{"id":152,"type":"single","stem":"检查井下压风自救装置时，判定其失效的关键指标是","options":["装置外壳有少量积尘","供气压力不足且面罩破损","安装位置距工作面较远","箱体颜色与标识不符"],"answer":[1],"explanation":"知识点是压风自救装置完好标准。供气压力不足和面罩破损直接影响使用，判定失效；错项积尘、位置、颜色不是关键失效指标。"},{"id":153,"type":"single","stem":"井下检查发现探放水钻孔孔口管未安装闸阀，正确的处理意见是","options":["允许继续钻进但记录","停止钻进并补装闸阀","允许钻进但降低钻速","允许钻进并加强观测"],"answer":[1],"explanation":"知识点是探放水孔口管控制要求。未装闸阀无法控制涌水，应停止并补装；错项继续钻进的各种变通均存在突水失控风险。"},{"id":154,"type":"single","stem":"检查井下密闭墙时，发现墙前有水渗出且密闭内气体压力增大，安全检查工应","options":["撤出附近人员并设置警戒后报告","打开密闭泄压后继续检查","在墙前钻孔放水后离开","用木楔封堵渗水点后记录"],"answer":[0],"explanation":"知识点是密闭墙异常处置。渗水加压力增大可能溃水，正确项撤人警戒报告；错项打开密闭、钻孔放水、木楔封堵均可能引发突然溃水。"},{"id":155,"type":"multi","stem":"井下安全检查中发现下列哪些情形时，必须立即停止作业并撤出人员","options":["采掘工作面瓦斯浓度超限","局部通风机无计划停风","巷道顶板出现连续掉渣","运输大巷照明亮度偏低","消防管路阀门轻微渗漏"],"answer":[0,1,2],"explanation":"知识点是立即停产撤人的重大隐患判别。瓦斯超限、无计划停风、顶板连续掉渣均属立即撤人情形；照明偏低、阀门轻微渗漏不构成立即撤人条件。"},{"id":156,"type":"single","stem":"井下安全检查发现采煤工作面回风巷瓦斯浓度达到1.2%且持续上升，检查员首先应当采取的措施是","options":["责令现场作业人员停止工作并切断电源撤出人员","要求瓦检员加大风量继续观察浓度变化","通知班组长安排人员继续作业并加强监测","记录数据待升井后向调度室汇报处理"],"answer":[0],"explanation":"知识点：瓦斯超限应急处置。采掘工作面回风巷瓦斯浓度达到1.0%即须停止工作、撤人、断电。正确项对：超限立即停止作业撤人断电是规程要求。错误项'加大风量继续观察'错在超限后不得边作业边观察；'继续作业加强监测'错在超限状态下严禁作业；'升井后汇报'错在贻误处置时机。"},{"id":157,"type":"single","stem":"安全检查员在掘进工作面发现局部通风机风筒末端距工作面距离明显超过规定，可能造成的直接后果是","options":["工作面有效风量不足形成瓦斯积聚","风筒内风压升高导致风筒破裂","局部通风机负荷增大烧毁电机","巷道风速过大扬起积尘"],"answer":[0],"explanation":"知识点：局部通风管理。风筒末端距工作面过远，压入式通风射流达不到工作面，形成通风死角导致瓦斯积聚。正确项对。错误项'风压升高破筒'错在末端过远反而降低阻力和压力；'烧毁电机'错在负荷减小而非增大；'风速过大扬尘'错在末端过远使工作面风速反而降低。"},{"id":158,"type":"single","stem":"井下进行安全检查时发现某处电缆与压风管同侧敷设且间距不足，正确的判断和处理是","options":["电缆应与压风管分侧敷设或保持规定间距","只要电缆有铠装即可同侧紧贴敷设","将压风管临时用铁丝吊挂在电缆上方","在下井前已检查过即可不作现场处理"],"answer":[0],"explanation":"知识点：井下管线敷设安全间距。电缆与压风管、供水管同侧敷设时须保持规程规定间距，否则应分侧。正确项对。错误项'有铠装可紧贴'错在铠装不能免除间距要求；'铁丝吊挂压风管于电缆上方'错在加剧近距离且吊挂方式不合规；'下井前检查过不处理'错在现场隐患须现场纠正。"},{"id":159,"type":"single","stem":"矿井主要通风机停止运转后，井下安全检查员在人员撤离过程中的正确做法是","options":["按避灾路线组织人员撤至进风大巷并升井","留在原地等待通风机恢复后再撤出","打开风门利用自然风流通风后继续作业","进入回风巷查看停风原因并记录"],"answer":[0],"explanation":"知识点：主要通风机停风应急处置。停风后井下瓦斯涌出积聚，人员须按避灾路线撤至进风侧并升井。正确项对。错误项'原地等待'错在停风区域可能缺氧积瓦斯；'打开风门自然通风继续作业'错在停风期间严禁作业且开风门会破坏通风系统；'进入回风巷查看'错在回风侧最危险。"},{"id":160,"type":"single","stem":"煤矿安全检查作业中，判定采煤工作面支架是否失效需要重点观察的部件是","options":["立柱安全阀与液压管路密封状况","支架顶梁表面油漆脱落情况","支架底座与底板的接触面积","支架推移千斤顶的行程余量"],"answer":[0],"explanation":"知识点：液压支架完好标准。支架失效主要表现为安全阀失灵、管路漏液导致初撑力不足。正确项对。错误项'油漆脱落'属外观非功能指标；'底座接触面积'非失效判据且现场难量化；'推移行程余量'影响移架步距而非支撑失效。"},{"id":161,"type":"single","stem":"安全检查员在井下发现便携式甲烷检测报警仪显示数值与光学瓦检仪读数不一致时，正确的处理方式是","options":["以光学瓦检仪读数为准并送修便携仪","取两者平均值作为现场瓦斯浓度","以便携仪读数为准继续作业","两仪器都不可信须停止一切检查"],"answer":[0],"explanation":"知识点：瓦斯检测仪器使用。光学瓦检仪为法定精确检测手段，便携仪用于连续监测报警，读数矛盾时以光学仪为准并送检便携仪。正确项对。错误项'取平均值'错在无依据且可能掩盖超限；'以便携仪为准'错在精度和检定状态不确定；'停止一切检查'错在处置过度且不解决仪器问题。"},{"id":162,"type":"single","stem":"井下爆破作业后，安全检查员进入工作面检查前必须确认的条件是","options":["炮烟吹散、瓦斯浓度合格且支护完好","爆破工已清点剩余炸药数量","爆破母线已从发爆器上取下","警戒人员已全部撤回警戒线以内"],"answer":[0],"explanation":"知识点：爆破后安全检查条件。爆破后须待炮烟吹散、检查瓦斯和支护后方可进入。正确项对。错误项'清点炸药'是爆破管理内容但非进入前安全条件；'取下母线'是爆破操作步骤；'警戒撤回'是撤警戒程序，均不能单独保证进入安全。"},{"id":163,"type":"single","stem":"采煤工作面上下出口超前支护范围内发现单体液压支柱初撑力普遍偏低，安全检查员应认定为","options":["重大隐患须立即停止作业整改","一般问题可边生产边补充注液","正常现象因周期来压所致","只需记录在检查表内即可"],"answer":[0],"explanation":"知识点：支护质量隐患判定。上下出口超前支护初撑力不足会导致顶板下沉甚至冒顶，属须立即整改的隐患。正确项对。错误项'边生产边注液'错在未整改前不得作业；'周期来压正常'错在来压更需保证初撑力；'只记录'错在发现隐患须现场处置。"},{"id":164,"type":"single","stem":"煤矿井下安全检查发现某处密闭墙前瓦斯浓度超限且墙内有水渗出，正确的处置顺序是","options":["撤出人员、设置栅栏警标并汇报调度","直接拆开密闭墙查看内部情况","在密闭墙前加强通风稀释瓦斯","用泥土封堵渗水处后继续巡检"],"answer":[0],"explanation":"知识点：密闭区域隐患处置。密闭前瓦斯超限说明墙内可能积存瓦斯，须撤人、设警标、汇报，严禁擅自打开。正确项对。错误项'拆开密闭'错在可能引发瓦斯涌出伤人；'加强通风'错在通风可能把墙内瓦斯带出；'封堵渗水'错在未解决瓦斯超限根本问题。"},{"id":165,"type":"multi","stem":"煤矿井下安全检查员在采煤工作面发现下列哪些情形时应当责令立即停止作业","options":["工作面瓦斯浓度超过规定限值","支架顶梁严重歪斜咬架","刮板输送机机头未设防护栏","工作面温度达到26摄氏度","采煤机喷雾降尘装置效果良好"],"answer":[0,1],"explanation":"知识点：停止作业情形判定。瓦斯超限和支架严重歪斜咬架均直接威胁安全，须立即停止作业。正确项为前两项。错误项'机头未设防护栏'应责令限期整改但非立即停产情形；'26摄氏度'未达停产温度限值；'喷雾效果良好'属正常状态不构成隐患。"},{"id":166,"type":"single","stem":"煤矿井下检查时发现采煤工作面回风巷瓦斯浓度达到0.9%，检查人员应要求现场采取的处置措施是","options":["加强通风并停止工作面向该区域供电","停止工作面临时作业并撤出人员","维持生产但安排专人连续监测","加大风量并继续回采作业"],"answer":[1],"explanation":"知识点：瓦斯浓度达到0.9%已接近或达到停止作业撤人界限。正确项：停止作业、撤出人员是防止瓦斯事故扩大的基本处置。错误项：加强通风并停止供电不能替代撤人；维持生产只监测无法消除风险；加大风量继续回采属于冒险作业。"},{"id":167,"type":"single","stem":"检查井下局部通风机时，发现风筒末端距掘进工作面距离超过作业规程规定，首先应判定为","options":["通风系统不完善隐患","局部通风机安装位置错误","风筒吊挂不平直问题","掘进工作面风量分配不均"],"answer":[0],"explanation":"知识点：风筒末端距工作面距离超规定会导致工作面有效风量不足，属于通风系统不完善隐患。正确项：通风系统不完善是准确定性。错误项：风机安装位置是另一检查项；吊挂不平直属外观管理；风量分配不均不是该现象的直接定性。"},{"id":168,"type":"single","stem":"井下安全检查发现某处巷道顶板出现明显离层、淋水增大并伴有响声，检查人员应首先","options":["记录隐患并通知班后处理","组织撤出受威胁区域人员","设置警戒后继续观察顶板","安排人员在附近打设临时支柱"],"answer":[1],"explanation":"知识点：顶板离层、淋水增大并伴有响声是冒顶前兆。正确项：先撤出受威胁区域人员是首要处置。错误项：记录后班后处理会延误；设警戒继续观察仍使人员处于危险；打临时支柱未撤人不能优先保证安全。"},{"id":169,"type":"single","stem":"煤矿安全检查作业中，对井下使用的自救器进行抽查时，重点应确认其","options":["外壳颜色与编号是否统一","有效期限与气密性是否合格","佩戴绳长度是否便于携带","外壳是否有明显划痕"],"answer":[1],"explanation":"知识点：自救器防护性能取决于有效期和气密性。正确项：有效期限与气密性合格是能否可靠使用的关键。错误项：颜色编号属管理标识；佩戴绳长度属携带方便；外壳划痕不等于防护失效。"},{"id":170,"type":"single","stem":"检查采掘工作面综合防尘措施时，发现回风巷净化水幕未正常喷雾，正确的检查结论是","options":["属于防尘设施不完好隐患","属于通风设施不完善隐患","属于瓦斯抽采系统问题","属于机电设备失爆问题"],"answer":[0],"explanation":"知识点：净化水幕是综合防尘设施，未正常喷雾属于防尘设施不完好。正确项：定性为防尘设施不完好隐患。错误项：通风设施、瓦斯抽采、机电失爆均与净化水幕故障无直接对应关系。"},{"id":171,"type":"single","stem":"井下检查发现某电气设备外壳接合面有锈蚀且紧固螺栓缺失，检查人员应判定该设备","options":["属于不完好设备但可继续运行","属于失爆设备必须停止运行","属于待修设备可限时运行","属于受潮设备需烘干处理"],"answer":[1],"explanation":"知识点：隔爆接合面锈蚀、紧固螺栓缺失会破坏隔爆性能，属于失爆。正确项：失爆设备必须停止运行。错误项：不完好继续运行、限时运行、烘干处理均未抓住失爆这一关键。"},{"id":172,"type":"single","stem":"煤矿安全检查发现某掘进工作面未按规定执行“一炮三检”制度，正确的隐患定性是","options":["爆破管理制度执行不到位","瓦斯检查制度执行不到位","通风管理制度执行不到位","机电检修制度执行不到位"],"answer":[1],"explanation":"知识点：“一炮三检”是瓦斯检查制度的重要内容。正确项：未执行一炮三检属于瓦斯检查制度执行不到位。错误项：爆破、通风、机电检修制度均不能准确对应瓦斯检查环节的缺失。"},{"id":173,"type":"single","stem":"井下发生火灾时，现场安全检查人员首先要判断的内容是","options":["火灾燃烧物种类和火势方向","当班出勤人数和产量","通风机型号和功率","巷道支护方式和年限"],"answer":[0],"explanation":"知识点：火灾应急处置首先判断火源、燃烧物和火势方向，以决定撤人、灭火和控风方案。正确项：燃烧物种类和火势方向是首要判断。错误项：出勤人数、风机型号、支护方式不是火灾初期处置的首要判断内容。"},{"id":174,"type":"single","stem":"检查井下主要排水泵房时，发现工作水泵和备用水泵不能实现相互切换，应定性为","options":["排水系统不完善隐患","供电系统不完善隐患","通风系统不完善隐患","提升系统不完善隐患"],"answer":[0],"explanation":"知识点：主排水泵房工作泵与备用泵应能相互切换，不能切换属于排水系统不完善。正确项：定性为排水系统不完善隐患。错误项：供电、通风、提升系统与水泵切换功能不直接对应。"},{"id":175,"type":"single","stem":"煤矿安全检查作业中，检查人员发现某处密闭墙前有人员休息，正确的处置是","options":["提醒其注意安全后允许短时休息","立即劝离并检查密闭墙完好情况","记录后由班组长自行处理","设置警示牌后允许继续停留"],"answer":[1],"explanation":"知识点：密闭墙附近可能积聚有害气体且墙体状态不明，人员停留危险。正确项：立即劝离并检查密闭墙完好情况。错误项：提醒后允许、记录后班组长处理、设牌后允许停留均未及时消除风险。"},{"id":176,"type":"single","stem":"检查矿井安全监控系统时，发现某甲烷传感器调校周期超过规定，正确的处理是","options":["要求立即调校并记录为监控系统隐患","要求更换传感器并重新布线","要求停用该传感器并人工检测","要求调整报警值后继续使用"],"answer":[0],"explanation":"知识点：甲烷传感器须按规定周期调校，超期未调校属于监控系统隐患。正确项：立即调校并记录为监控系统隐患。错误项：更换布线、停用改人工、调整报警值均不是针对超期未调校的正确处理。"},{"id":177,"type":"single","stem":"煤矿井下检查时发现局部通风机风筒末端距掘进工作面距离超过作业规程规定，且风筒有破口漏风，作为安全检查工首先应当采取的措施是","options":["记录问题等升井后汇报","责令现场停止作业撤出人员","协助现场人员当场修补风筒","测量漏风量后判断是否超标"],"answer":[1],"explanation":"知识点：掘进工作面局部通风重大隐患的现场处置。风筒末端距离超规定且漏风，会造成工作面风量不足、瓦斯积聚，属于必须立即停止作业撤人的情形。正确项对：先停止作业撤出人员是防止事故扩大的首要措施。错误项1错在隐患未消除前不得只记录等待；错误项2错在未先保证人员安全就修补；错误项3错在现场测量不能替代撤人。"},{"id":178,"type":"single","stem":"煤矿安全规程规定，采掘工作面及其他作业地点风流中瓦斯浓度达到多少时，必须停止用电钻打眼","options":["0.5%","0.8%","1.0%","1.5%"],"answer":[2],"explanation":"知识点：瓦斯浓度限值与停止作业的对应关系。规程规定风流中瓦斯浓度达到1.0%时必须停止用电钻打眼，这是防止钻孔作业引燃瓦斯的关键限值。0.5%是采掘工作面回风巷瓦斯浓度超限报警的常见低值，不对应停止打眼；0.8%不是停止打眼的限值；1.5%是必须停止工作、撤人、断电的更高限值。"},{"id":179,"type":"single","stem":"井下安全检查工在采煤工作面发现上隅角瓦斯浓度达到1.2%，此时正确的处置程序是","options":["加强通风后继续观察","停止工作面作业并切断电源撤人","安排人员悬挂便携仪监测","通知瓦检员后继续巡视其他地点"],"answer":[1],"explanation":"知识点：采煤工作面上隅角瓦斯超限处置。上隅角瓦斯达1.2%已超过1.0%限值，属于超限，必须停止作业、切断电源、撤出人员。正确项对：超限处置的核心是停、断、撤。错误项1错在超限不能仅加强通风后继续作业；错误项2错在挂仪器监测不能代替撤人断电；错误项3错在通知他人不能代替本岗位立即处置。"},{"id":180,"type":"single","stem":"煤矿井下检查中发现某处密闭墙前有积水且墙体出现裂缝，墙体附近有异常气味，正确的判断是","options":["密闭墙渗水属正常现象无需处理","可能存在采空区积水或有害气体涌出","只需在墙外设置警示牌即可","待雨季过后再安排人员检查处理"],"answer":[1],"explanation":"知识点：密闭墙异常与采空区隐患识别。墙体裂缝、积水、异常气味提示采空区可能积水或有害气体外泄。正确项对：这些征兆需按采空区隐患对待并及时上报处理。错误项1错在渗水加裂缝并非正常；错误项2错在仅设警示牌不能消除隐患；错误项3错在拖延处理会扩大风险。"},{"id":181,"type":"single","stem":"煤矿井下发生火灾时，安全检查工在现场发现火势较小且位于进风侧，正确的首要处置原则是","options":["立即组织人员直接扑灭","迅速报告并组织人员佩戴自救器撤离","先切断电源再考虑撤人","打开风门增加风量稀释烟雾"],"answer":[1],"explanation":"知识点：井下火灾应急处置原则。井下火灾首要任务是保证人员安全撤离并报告，进风侧火灾烟雾会迅速蔓延。正确项对：先报告并组织撤离符合救人第一原则。错误项1错在未判断火势与逃生条件就扑救；错误项2错在撤人优先于切断电源；错误项3错在打开风门会助长火势和烟雾蔓延。"},{"id":182,"type":"single","stem":"煤矿安全检查作业中，检查采掘工作面顶板时发现顶板出现新的裂隙且伴有掉渣，正确的处置是","options":["继续作业并加强观察","立即停止作业撤出人员并报告","安排人员用长柄工具敲帮问顶","在裂隙处打设临时支柱后恢复作业"],"answer":[1],"explanation":"知识点：顶板冒落前兆识别与处置。新裂隙加掉渣是顶板冒落的明显前兆。正确项对：应立即停止作业撤人并报告。错误项1错在前兆出现后不能继续作业；错误项2错在敲帮问顶本身有危险且不能代替撤人；错误项3错在未撤人先支护本末倒置。"},{"id":183,"type":"single","stem":"煤矿井下使用的便携式甲烷检测报警仪，其报警点应设置在甲烷浓度达到多少时发出声光报警","options":["0.5%","0.8%","1.0%","1.5%"],"answer":[2],"explanation":"知识点：便携式甲烷检测报警仪报警点设置。规程要求报警点设定为1.0%CH4，与瓦斯作业限值一致。0.5%低于作业限值，过早报警干扰作业；0.8%不是规定报警点；1.5%是断电撤人限值，作为报警点则失去预警作用。"},{"id":184,"type":"single","stem":"煤矿安全检查工在检查井下爆破作业时，发现爆破员在装药前未检查炮眼内瓦斯浓度，正确的处置是","options":["提醒爆破员下次注意","立即制止并要求检查瓦斯后再装药","记录后由班组长处理","要求爆破员加快装药速度"],"answer":[1],"explanation":"知识点：爆破作业前瓦斯检查要求。装药前必须检查炮眼内瓦斯浓度，超限禁止装药。正确项对：应立即制止并督促检查。错误项1错在提醒不能消除当前隐患；错误项2错在记录后处理会放任违章；错误项3错在加快装药会增加风险。"},{"id":185,"type":"single","stem":"煤矿井下检查时发现某掘进巷道局部通风机出现循环风，正确的判断与处置是","options":["循环风可提高工作面风量无需处理","循环风会导致瓦斯积聚必须立即处理","只需调整风筒角度即可继续作业","待下一班再安排人员调整通风"],"answer":[1],"explanation":"知识点：局部通风机循环风的危害与处置。循环风会使工作面新鲜风量减少、瓦斯和粉尘积聚。正确项对：循环风必须立即处理。错误项1错在循环风降低有效风量；错误项2错在简单调整角度不能根本解决；错误项3错在拖延处理会酿成事故。"},{"id":186,"type":"single","stem":"煤矿井下安全检查工进入采空区附近检查时，发现巷道内氧气浓度明显下降且伴有头晕感，正确的处置是","options":["坚持完成检查后撤离","立即撤离到新鲜风流中并报告","原地休息待症状缓解","打开随身照明仔细查看"],"answer":[1],"explanation":"知识点：井下缺氧环境识别与自救。氧气浓度下降伴头晕是缺氧征兆，继续停留会窒息。正确项对：应立即撤到新鲜风流并报告。错误项1错在不能坚持检查；错误项2错在原地休息会加重缺氧；错误项3错在照明查看不能解决缺氧。"},{"id":187,"type":"single","stem":"井下安全检查工在采煤工作面进风巷发现瓦斯浓度达到0.8%且仍在缓慢上升，此时应优先采取的措施是","options":["继续观测并记录变化趋势","通知工作面人员撤离并切断电源","加大风量稀释后恢复作业","安排专人盯守等待浓度稳定"],"answer":[1],"explanation":"知识点：瓦斯超限应急处置。瓦斯浓度持续上升说明涌出异常，存在爆炸风险，应立即撤人断电。继续观测会延误撤人时机；加大风量无法保证稀释效果且带电作业危险；专人盯守不能消除爆炸风险。"},{"id":188,"type":"single","stem":"煤矿井下安全检查中，发现掘进工作面局部通风机发生循环风的正确判断依据是","options":["风筒出口风量比风机吸风量明显偏小","巷道内粉尘浓度比平时升高","风机运转声音比正常时沉闷","回风流中二氧化碳浓度略有上升"],"answer":[0],"explanation":"知识点：循环风识别。循环风的本质是部分回风被风机重新吸入，表现为风筒出口风量明显小于风机吸风量。粉尘升高、声音沉闷、二氧化碳略升都不是循环风的判断依据。"},{"id":189,"type":"single","stem":"安全检查工在井下发现有人擅自打开密闭墙进入旧巷取材料，正确的处置程序是","options":["当场制止并报告调度室等候处理","陪同进入查看有无瓦斯积聚","记录情况后升井再向领导汇报","先帮其取完材料再封闭密闭"],"answer":[0],"explanation":"知识点：密闭墙管理。擅自打开密闭属严重违章，可能引发中毒窒息，应立即制止并报告。陪同进入会使自己陷入危险；事后汇报延误处置；帮取材料等于参与违章。"},{"id":190,"type":"single","stem":"煤矿井下使用的便携式甲烷检测报警仪，每次使用前必须进行的检查项目是","options":["光干涉条纹是否清晰","电池电压和报警功能是否正常","外壳是否涂有防爆标志","零点是否用新鲜空气调校"],"answer":[1],"explanation":"知识点：便携仪使用前检查。使用前必须确认电量充足、报警功能可靠。光干涉条纹是光学式检定内容；防爆标志是出厂属性不需每次查；零点调校应在清洁空气中按规程进行但非使用前必查项。"},{"id":191,"type":"single","stem":"井下采掘工作面安全检查中，判断支护是否失效最直接的现场依据是","options":["支柱表面油漆是否脱落","支架是否有明显变形、折断或退山","支护材料是否为同一批次","支护间距是否与设计图纸一致"],"answer":[1],"explanation":"知识点：支护状态检查。支护失效的直接表现是变形、折断、退山等受力破坏特征。油漆脱落是外观问题；同批次材料不能说明失效；间距一致但支架已变形仍属失效。"},{"id":192,"type":"single","stem":"井下安全检查工发现某处巷道顶板出现淋水增大且水色变浑，最应警惕的是","options":["顶板来压或断层导水的前兆","巷道内湿度偏高的正常现象","喷雾降尘水量开得过大","排水沟排水不畅造成积水"],"answer":[0],"explanation":"知识点：顶板水害预兆。淋水增大并变浑常是顶板裂隙扩展、断层导水的征兆，可能伴随冒顶或突水。湿度高、喷雾、排水不畅都不会使淋水突然增大变浑。"},{"id":193,"type":"single","stem":"煤矿井下爆破作业中，安全检查工发现炮眼封泥长度不足，正确的处理方式是","options":["要求立即停止装药并重新封泥","允许放炮后下一循环补足","让放炮员自行决定是否放炮","记录后由班组长决定是否放炮"],"answer":[0],"explanation":"知识点：爆破封泥要求。封泥不足会导致爆破火焰直接冲出，易引爆瓦斯煤尘，必须停止装药重新封泥。放炮后补足、放炮员自定、班组长决定都违反规程。"},{"id":194,"type":"single","stem":"井下电气设备检查中，发现开关外壳紧固螺栓缺少一颗，正确的处置是","options":["用铁丝临时绑扎后继续使用","立即停止使用并按规定处理","只要不影响操作可继续运行","用同规格螺栓自行补装后送电"],"answer":[1],"explanation":"知识点：矿用电气设备防爆性能。缺紧固螺栓会破坏隔爆外壳完整性，必须停用处理。铁丝绑扎、继续运行、自行补装送电都不符合防爆管理要求。"},{"id":195,"type":"single","stem":"安全检查工在井下发现一氧化碳浓度超限且有人出现头痛症状，最优先的处置是","options":["给症状人员服用解毒药物","立即撤出人员并报告调度室","加大风量后继续作业观察","让症状人员休息后继续工作"],"answer":[1],"explanation":"知识点：一氧化碳中毒应急。CO超限且有人中毒症状，首要任务是撤人并报告，防止更多人员中毒。服药、加大风量后作业、休息后继续工作都会延误救援。"},{"id":196,"type":"single","stem":"井下安全检查中，判断局部通风机是否发生无计划停风的直接依据是","options":["风筒是否有破口漏风","风机运转指示灯是否熄灭","巷道内温度是否升高","工作面人员是否感到闷热"],"answer":[1],"explanation":"知识点：局部通风机运行状态。无计划停风的直接信号是风机停止运转、指示灯熄灭。风筒破口、温度升高、人员闷热都是间接或无关表现。"},{"id":197,"type":"single","stem":"煤矿井下安全检查工在采煤工作面发现煤壁片帮频繁且支架压力增大，应判断为","options":["顶板来压的明显征兆","煤层含水量偏高的表现","采煤机截割速度过快","运输机负荷过大的反映"],"answer":[0],"explanation":"知识点：顶板来压预兆。片帮频繁加支架压力增大是典型的顶板来压征兆，需加强支护。含水量、截割速度、运输机负荷都不会直接导致片帮和支架压力同时增大。"},{"id":198,"type":"multi","stem":"煤矿井下安全检查工在掘进工作面发现下列哪些情况时，应当立即停止作业并撤出人员","options":["瓦斯浓度达到1.5%且继续上升","局部通风机无计划停风","顶板出现严重掉渣且支架变形","巷道内粉尘浓度略高于平时","风筒接口有轻微漏风"],"answer":[0,1,2],"explanation":"知识点：掘进工作面紧急停止作业条件。瓦斯超限上升、无计划停风、顶板严重异常都属立即撤人情形。粉尘略高、风筒轻微漏风属一般问题，应整改但不需立即撤人。"},{"id":199,"type":"single","stem":"井下巷道维修时，安全检查工发现一段支架顶梁出现明显弯曲变形但尚未折断，正确的处置是","options":["先撤出人员再设置临时支护后处理","立即用木料打点柱加固后继续作业","记录在隐患台账中待修班统一处理","通知班长后继续观察变形是否发展"],"answer":[0],"explanation":"知识点：顶板支护隐患的应急处置。正确项先撤人再临时支护，符合'先安全后作业'原则。错误项'立即打点柱继续作业'未先撤人，变形顶梁随时可能失效；'记录待统一处理'延误处置，弯曲变形属紧急隐患；'通知后继续观察'在危险区滞留，违反撤人优先原则。"},{"id":200,"type":"single","stem":"煤矿井下爆破作业后，安全检查工进入检查时最先应确认的事项是","options":["爆破地点通风是否恢复正常","爆破器材是否全部回收","爆破后煤壁是否出现片帮","爆破效果是否达到循环进度"],"answer":[0],"explanation":"知识点：爆破后检查程序。正确项先确认通风恢复，因爆破产生大量炮烟和有害气体，通风未恢复前进入会中毒窒息。错误项器材回收、片帮、进度均在通风确认之后进行，顺序错误。"},{"id":201,"type":"single","stem":"井下局部通风机因故障停止运转，恢复通风前安全检查工必须组织检查的是","options":["停风区瓦斯浓度和二氧化碳浓度","风机轴承温度和电机绝缘","风筒吊挂是否平直牢固","风筒出口到工作面的距离"],"answer":[0],"explanation":"知识点：停风区恢复通风的气体检查要求。正确项先检查瓦斯和二氧化碳浓度，超限时须先排放。错误项轴承温度、风筒吊挂、出口距离属日常检查项目，不是恢复通风前的首要条件。"},{"id":202,"type":"single","stem":"检查井下电气设备时，发现一台开关的接地线连接螺栓松动，正确的处置是","options":["停电后重新紧固并测量接地电阻","带电用扳手直接紧固该螺栓","用铜丝缠绕临时固定后继续使用","登记后等检修班停电时处理"],"answer":[0],"explanation":"知识点：接地保护装置检查与处置。正确项停电紧固并测接地电阻，确保保护有效。错误项带电紧固违反停电作业规定；铜丝缠绕不能保证可靠连接；登记待处理使设备带隐患运行。"},{"id":203,"type":"single","stem":"采煤工作面回风巷检查时发现一氧化碳浓度持续升高，安全检查工下一步应做的是","options":["立即撤出人员并报告调度室","加大风量后继续观察浓度变化","佩戴自救器继续向前检查","记录数据后按原路线返回"],"answer":[0],"explanation":"知识点：CO持续升高可能预示自燃或火灾。正确项撤人并报告，属紧急处置。错误项加大风量可能助燃；佩戴自救器继续检查使人员处于危险；记录返回延误报警时机。"},{"id":204,"type":"single","stem":"井下人力推车时，安全检查工发现两车在同轨道同方向行驶间距过小，正确的判断是","options":["同方向推车间距不得小于10米","同方向推车间距不得小于5米","同方向推车间距不得小于20米","同方向推车间距不得小于30米"],"answer":[0],"explanation":"知识点：人力推车间距规定。正确项10米，符合规程要求。错误项5米过近易追尾；20米、30米数值偏大，非规定间距。"},{"id":205,"type":"single","stem":"检查井下消防材料库时，发现灭火器压力表指针处于红区，正确的处置是","options":["立即更换或充装该灭火器","摇动瓶体后继续存放备用","记录后待年度检查时处理","将灭火器倒置存放待压力回升"],"answer":[0],"explanation":"知识点：灭火器有效性检查。正确项指针在红区表示压力不足，须立即更换或充装。错误项摇动、倒置不能恢复压力；待年度检查延误，火灾时无法使用。"},{"id":206,"type":"single","stem":"掘进工作面检查时发现风筒末端距工作面距离超过规定，可能造成的直接后果是","options":["工作面有效风量不足导致瓦斯积聚","风筒内阻力增大导致风机过载","风筒出口风速过高吹起煤尘","风机负压升高导致风筒吸瘪"],"answer":[0],"explanation":"知识点：风筒出口距离与有效通风。正确项距离超限使射流达不到工作面，瓦斯易积聚。错误项阻力、风速、负压均非该距离超限的直接主导后果，属相邻概念干扰。"},{"id":207,"type":"single","stem":"井下发现有人触电，安全检查工在附近且未采取绝缘措施时，正确的首要动作是","options":["迅速切断电源或用绝缘物挑开电线","直接用手拉开触电者脱离电源","先向调度室报告等待指示","用铁锹把电线从触电者身上拨开"],"answer":[0],"explanation":"知识点：触电急救第一步。正确项切断电源或用绝缘物挑开电线。错误项直接用手会导致施救者触电；先报告延误抢救；铁锹非绝缘物，同样导电危险。"},{"id":208,"type":"single","stem":"检查采煤工作面上下出口时，发现出口高度低于规定值且未采取措施，正确的处置是","options":["责令停止作业并限期整改","允许作业但要求加强支护","记录后由下一班自行处理","要求作业人员弯腰通过即可"],"answer":[0],"explanation":"知识点：安全出口高度规定及隐患处置。正确项责令停止作业限期整改，出口不畅通属重大隐患。错误项允许作业、下一班处理、弯腰通过均属降低标准、带隐患生产。"},{"id":209,"type":"single","stem":"井下巷道贯通前，安全检查工检查贯通措施落实情况时，重点应确认的是","options":["贯通点两侧支护和通风是否可靠","贯通后运输路线是否最短","贯通点岩石硬度是否便于施工","贯通施工进度是否满足计划"],"answer":[0],"explanation":"知识点：巷道贯通安全措施。正确项重点确认两侧支护和通风可靠，防止贯通时冒顶和瓦斯事故。错误项运输路线、岩石硬度、施工进度均非贯通安全的核心确认内容。"},{"id":210,"type":"single","stem":"煤矿安全检查作业人员进入采煤工作面检查时，发现上下安全出口超前支护段单体液压支柱有连续三根失效，正确处置方式是","options":["在失效支柱旁补打临时点柱后继续生产","认定为重大隐患，责令停止作业并撤出人员","通知维修班次日检修时一并更换","降低采煤机牵引速度后继续推采"],"answer":[1],"explanation":"知识点：采煤工作面顶板隐患判定。超前支护连续多根失效使出口段顶板失去有效支撑，属重大隐患，必须停产撤人。补打临时点柱不能替代系统支护且仍处在危险区域；次日检修会长时间保持危险状态；降低牵引速度与支护失效无因果关系，不能消除顶板事故风险。"},{"id":211,"type":"single","stem":"检查井下电气设备时，发现一台正在运行的局部通风机开关接线腔盖板缺少紧固螺栓，检查人员应","options":["用随身工具补装同规格螺栓后放行","判定为失爆，责令停止该设备运行并处理","在盖板缝隙处贴防爆胶带临时封堵","记录后要求电工在下个检修班补齐螺栓"],"answer":[1],"explanation":"知识点：矿用电气设备失爆判定。隔爆接合面紧固螺栓缺失即构成失爆，必须停运处理。自行补装螺栓不解决接合面是否完好问题且非专职电工操作；贴胶带不能恢复隔爆性能；延迟到检修班处理会使失爆设备持续运行，存在引爆风险。"},{"id":212,"type":"single","stem":"井下发生瓦斯煤尘爆炸事故后，现场安全检查人员组织撤离时，正确的行进方向是","options":["沿进风巷道迎风撤离至新鲜风流中","沿回风巷道顺风快速撤离至井底","就近进入采空区躲避后等待救援","沿原进路返回并通过盲巷绕行"],"answer":[0],"explanation":"知识点：爆炸事故避灾路线。爆炸后有大量有毒有害气体，应迎着新鲜风流即沿进风巷撤离。沿回风巷顺风撤离会进入有毒气体区域；采空区无支护且可能积聚瓦斯，进入等于自陷险境；盲巷无风且易积存有害气体，绕行会加重危险。"},{"id":213,"type":"single","stem":"煤矿安全检查人员对井下爆破作业进行检查时，发现爆破工在装药前未检查瓦斯浓度即开始装药，正确的判定是","options":["只要爆破地点20m内无异常即可装药","属违章作业，必须立即制止并纠正","由班组长口头提醒后可以继续装药","装药后再补测瓦斯浓度即可符合要求"],"answer":[1],"explanation":"知识点：爆破前瓦斯检查规定。装药前必须检查爆破地点附近瓦斯浓度，这是防止瓦斯爆炸的关键环节。以无异常代替实测没有依据；口头提醒不能替代停止违章行为；先装药后补测已使危险作业完成，顺序错误无法补救。"},{"id":214,"type":"single","stem":"检查矿井主要通风机运行状况时，发现风机轴承温度超过规定值且伴有异常振动，检查人员应","options":["通知司机加强观察并记录温度变化","立即报告并督促停止风机运行检查","开大风门增加风量以降低轴承温度","切换备用风机前先降低主轴转速"],"answer":[1],"explanation":"知识点：主要通风机异常运行处置。轴承超温伴振动可能预示轴承损坏，必须停机检查，否则一旦停风将导致全矿停风。只观察记录会放任故障发展；开大风门与轴承温度无直接关系；降速运行不能消除机械故障且仍存在突然停风风险。"},{"id":215,"type":"single","stem":"在井下检查中发现一氧化碳便携仪报警，且闻到焦糊味，检查人员确认火源前最优先的行动是","options":["佩戴自救器沿回风侧查找火源位置","立即向调度室报告并按避灾路线撤离","取来灭火器直接扑灭可见明火","关闭附近风门以控制风流短路"],"answer":[1],"explanation":"知识点：井下火灾初期应急处置。发现火灾迹象应首先报告并撤离，确保自身安全，由专业救护队处置。未确认火源就沿回风侧查找会进入中毒危险区；单独取灭火器扑救缺乏防护和支援；擅自关闭风门可能造成风流紊乱、瓦斯积聚，反而扩大灾害。"},{"id":216,"type":"single","stem":"煤矿安全检查人员检查提升钢丝绳时，发现钢丝绳在一个捻距内断丝断面积与总断面积之比达到规定限度，应当判定为","options":["可以继续使用但需缩短检查周期","必须立即停止使用并更换钢丝绳","降低提升速度后可继续使用","截去断丝段后插接继续使用"],"answer":[1],"explanation":"知识点：提升钢丝绳报废标准。一个捻距内断丝断面积与总断面积之比达到规定值即达到报废标准，必须停用更换。缩短检查周期、降速使用都是在用报废绳，不能保证安全；截断插接会改变绳长和强度，且插接工艺要求严格，不能作为现场处理方式。"},{"id":217,"type":"single","stem":"检查采掘工作面综合防尘措施时，发现掘进机内喷雾装置部分喷嘴堵塞、外喷雾水压不足，正确的处置意见是","options":["要求先恢复内外喷雾正常再允许掘进作业","允许作业但要求司机佩戴防尘口罩","要求每班冲洗一次巷道积尘即可","允许作业但需增加洒水车喷雾次数"],"answer":[0],"explanation":"知识点：掘进机喷雾降尘要求。内喷雾堵塞、外喷雾水压不足会使割煤产尘大幅增加，必须修复喷雾系统后方可作业。佩戴防尘口罩是辅助个体防护，不能替代喷雾降尘；冲洗巷道积尘属于事后清扫，不解决产尘源；洒水车喷雾无法在割煤点就地降尘。"},{"id":218,"type":"single","stem":"在井下检查时发现有人违章带电检修电气设备，检查人员应当","options":["要求其先切断电源并挂牌后再作业","提醒其注意安全后允许继续检修","记录违章人员姓名交班后处理","帮助其递送工具以缩短检修时间"],"answer":[0],"explanation":"知识点：电气检修停送电制度。检修必须停电、闭锁、挂牌，严禁带电作业。仅提醒注意安全不能制止违章；记录后交班处理会放任当前危险；帮助递送工具等于参与违章作业，均不符合安全检查人员职责。"},{"id":219,"type":"multi","stem":"煤矿安全检查人员对井下运输系统进行检查时，下列属于必须立即停止运输作业并整改的情形有","options":["斜巷跑车防护装置被拆除未恢复","带式输送机防打滑保护装置失效","运输巷道照明灯具间距略大于设计值","刮板输送机机头机尾未打设压柱","带式输送机个别托辊转动不灵活"],"answer":[0,1,3],"explanation":"知识点：运输系统重大隐患判定。跑车防护装置缺失、防打滑保护失效、机头机尾无压柱均直接危及人身安全，必须停运整改。照明灯具间距略大于设计值属一般问题，可限期完善；个别托辊转动不灵活影响较小，属日常维护范围，均不构成立即停运条件。"},{"id":220,"type":"single","stem":"井下采掘工作面回风流中甲烷浓度达到多少时，安全检查工必须责令现场人员停止作业并撤至安全地点","options":["1.0%","1.5%","2.0%","3.0%"],"answer":[0],"explanation":"知识点：采掘工作面回风流瓦斯浓度达到1.0%时必须停止作业、撤人。正确项1.0%符合规程对回风流甲烷的停止作业界限。1.5%是采掘工作面进风流中允许的最高浓度而非回风流停止作业界限；2.0%是采区回风巷等地点需要处理的界限，不是本题回风流撤人界限；3.0%是串联通风等特殊环节的浓度值，不能作为回风流停止作业界限。"},{"id":221,"type":"single","stem":"局部通风机因故障停止运转后，检查工在恢复通风前首先应做的检查是","options":["检查风筒是否脱节","检查瓦斯是否积聚","检查风机是否反转","检查开关是否复位"],"answer":[1],"explanation":"知识点：停风后恢复通风前必须先检查瓦斯，只有瓦斯浓度符合规定才可启动风机。正确项检查瓦斯是恢复通风的前置条件。检查风筒脱节属于送风后的完好性检查；检查风机反转属于启动后的运行检查；检查开关复位属于电气操作步骤，均不能替代瓦斯检查。"},{"id":222,"type":"single","stem":"井下巷道维修时，检查工发现作业地点上方有活矸但未处理，作业人员仍准备继续施工，正确的处置是","options":["要求先停止作业再处理活矸","允许边施工边观察活矸","要求作业人员戴手套继续作业","要求加快进度后统一处理"],"answer":[0],"explanation":"知识点：维修作业前必须先处理危岩活矸，否则不得作业。正确项要求先停止作业再处理活矸符合'先处理隐患后作业'原则。允许边施工边观察违反不安全不作业要求；戴手套不能防止活矸坠落伤人；加快进度后统一处理会扩大暴露风险。"},{"id":223,"type":"single","stem":"井下采煤工作面液压支架初撑力不足时，安全检查工应重点核查的工序是","options":["支架的移架顺序","支架的支护质量","支架的供液压力","支架的编号牌板"],"answer":[2],"explanation":"知识点：初撑力不足多与泵站供液压力偏低或管路漏液有关，应核查供液压力。正确项供液压力直接决定初撑力大小。移架顺序影响顶板管理但不直接决定初撑力；支护质量是结果性检查；编号牌板属于现场管理标识，与初撑力无关。"},{"id":224,"type":"single","stem":"掘进工作面采用锚杆支护时，检查工发现锚杆托盘未紧贴岩面，正确的判定是","options":["托盘未贴岩面但锚杆已注药，可判定合格","托盘未贴岩面属于支护质量问题，应整改","托盘未贴岩面只要锚杆外露长度合格即可","托盘未贴岩面在破碎围岩中属于正常现象"],"answer":[1],"explanation":"知识点：锚杆托盘必须紧贴岩面并施加预紧力，否则支护失效。正确项将其判定为支护质量问题并要求整改。已注药不代表托盘受力合格；外露长度合格不能替代托盘贴岩要求；破碎围岩更需托盘贴岩控制浅部围岩，不能视为正常。"},{"id":225,"type":"single","stem":"井下带式输送机运行中，检查工发现输送带跑偏且托辊有异响，下一步最恰当的做法是","options":["通知司机加速观察跑偏是否消失","要求立即停机并检查托辊与调偏装置","用手直接扳动输送带调整方向","在机尾加设临时挡板限制跑偏"],"answer":[1],"explanation":"知识点：输送带跑偏并伴随异响说明托辊或调偏装置异常，应立即停机检查处理。正确项要求立即停机并检查托辊与调偏装置，符合先停机后处理原则。加速观察会扩大故障；用手直接扳动输送带极易造成绞伤；加设临时挡板只是掩盖跑偏，不能消除原因。"},{"id":226,"type":"single","stem":"井下电气设备检查中，发现开关腔内壁有轻微受潮痕迹，正确的处置是","options":["通电烘干后继续使用","擦拭后直接恢复送电","停电处理并查明受潮原因","降低负荷后继续运行"],"answer":[2],"explanation":"知识点：井下电气设备受潮会降低绝缘，必须停电处理并查明原因。正确项停电处理并查明受潮原因符合电气安全要求。通电烘干存在短路风险；擦拭后直接送电未消除受潮根源；降低负荷不能解决绝缘降低问题。"},{"id":227,"type":"single","stem":"井下爆破作业中，检查工在装药前发现炮眼内有岩粉未清除干净，正确的处置是","options":["装药时用炮棍轻轻压实即可","要求先清除岩粉再装药","增加炮泥封堵长度后装药","改用较小直径药卷直接装入"],"answer":[1],"explanation":"知识点：炮眼内岩粉未清除会造成装药不连续、拒爆或爆燃，装药前必须清孔。正确项要求先清除岩粉再装药。炮棍压实不能清除岩粉；增加炮泥只影响封孔质量；改用小直径药卷仍无法解决孔内残留物问题。"},{"id":228,"type":"single","stem":"井下发生火灾时，检查工在无法直接灭火且火势发展较快的情况下，正确的处置顺序是","options":["先汇报再组织撤离","先撤离再汇报","先抢救设备再撤离","先封闭巷道再撤离"],"answer":[0],"explanation":"知识点：火势难以控制时应先汇报并按避灾路线撤离，汇报与撤离可同步但汇报是启动应急的关键。正确项先汇报再组织撤离符合应急报告优先原则。先撤离再汇报会延误救援指挥；抢救设备会危及人员安全；封闭巷道需专业方案，不能作为个人先行动作。"},{"id":229,"type":"single","stem":"井下检查中发现某处密闭墙前瓦斯浓度超限且有气体逸出，检查工正确的做法是","options":["在密闭墙前设置警示并汇报","打开密闭墙通风稀释瓦斯","用黄泥临时封堵逸出点","在附近继续作业并观察变化"],"answer":[0],"explanation":"知识点：密闭墙前瓦斯超限且逸出说明密闭内积存瓦斯，应警示并汇报，严禁擅自打开。正确项设置警示并汇报符合隐患处置要求。打开密闭墙会导致瓦斯大量涌出；临时封堵不能消除内部积存；继续作业会使人员处于危险区域。"},{"id":230,"type":"single","stem":"井下检查时发现局部通风机因故停止运转，恢复通风前必须先检查哪一项才能启动局部通风机","options":["停风区内的甲烷浓度","局部通风机电机温度","风筒的悬挂是否平直","巷道内的空气温度"],"answer":[0],"explanation":"知识点：停风后恢复通风的启动条件。停风区域可能积聚甲烷，规程要求先检查甲烷浓度，只有浓度不超限才允许人工启动局部通风机，防止一启动就吹出高浓度瓦斯形成爆炸条件。局部通风机电机温度不是启动前置条件，风筒悬挂平直是日常质量标准，空气温度与瓦斯积聚无直接启动关联。"},{"id":231,"type":"single","stem":"采煤工作面回风隅角甲烷浓度达到1.5%时，现场安全检查人员的正确处置是","options":["责令停止工作、撤出人员并切断电源","要求提高风速把瓦斯稀释后继续作业","安排瓦检员加密检测后维持生产","让作业人员佩戴自救器继续作业"],"answer":[0],"explanation":"知识点：甲烷超限的现场处置。回风隅角甲烷达到1.5%已超过规程允许浓度，必须停止工作、撤人、切断电源并报告，防止继续作业产生火源引爆瓦斯。提高风速稀释属于未先停产的冒险做法；加密检测但不停产不能消除爆炸风险；佩戴自救器不能代替撤人。"},{"id":232,"type":"single","stem":"安全检查工在掘进工作面发现风筒末端距工作面超过规定距离，最应优先判断的风险是","options":["工作面有效风量不足导致瓦斯积聚","风筒内阻力增大导致风压升高","风机负荷下降导致电机过热","巷道粉尘浓度会自行降低"],"answer":[0],"explanation":"知识点：风筒末端距工作面的允许距离。末端过远会造成工作面风流短路、有效风量不足，易形成瓦斯积聚，这是安全检查最关注的后果。风筒阻力增大与末端距离无必然关系；风机负荷反而可能下降；粉尘浓度不会因末端过远而自行降低。"},{"id":233,"type":"single","stem":"某矿安全检查工在斜巷提升时发现跑车防护装置处于常开状态，正确的处置是","options":["立即制止提升作业并督促恢复防护装置","要求提升机司机减速通过该区段","在斜巷下口增设警戒后继续提升","记录问题待当班结束后再整改"],"answer":[0],"explanation":"知识点：斜巷跑车防护装置的作用。防护装置常开则失去挡车功能，一旦跑车会直接威胁下方人员，属于必须立即停止作业的隐患。减速通过不能消除跑车动能；增设警戒不能阻止跑车；待班后整改属于拖延处置。"},{"id":234,"type":"single","stem":"井下发生火灾时，安全检查工在现场判断风流方向后，组织人员撤退应优先选择","options":["迎着新鲜风流方向撤至安全地点","顺着火烟流动方向快速撤离","在原地等待救护队到达","进入火区上风侧巷道躲避"],"answer":[0],"explanation":"知识点：火灾时的避灾原则。火灾时有害气体随风流蔓延，应迎着新鲜风流撤退，避免进入火烟流经区域。顺火烟方向撤离会吸入有毒气体；原地等待会丧失逃生时机；进入火区上风侧巷道可能被火势波及。"},{"id":235,"type":"single","stem":"煤矿安全检查工在采掘工作面发现顶板出现新的裂隙并伴有掉渣，最恰当的处置是","options":["立即撤出人员并设置警戒后报告","安排人员用长柄工具敲帮问顶后继续作业","加强支护后让作业人员继续施工","记录裂隙位置并观察一个班次"],"answer":[0],"explanation":"知识点：顶板冒落预兆的处置。新裂隙伴掉渣是冒顶前兆，应先撤人、设警戒、报告，再研究处理。敲帮问顶须在安全条件下由有经验人员操作，不能作为继续作业的理由；加强支护需在撤人后由专业人员实施；观察一个班次会延误撤人时机。"},{"id":236,"type":"single","stem":"检查井下使用的矿灯时，发现灯头密封圈缺失，正确的处置是","options":["该矿灯不得发放使用，应送修","只要灯能亮就可发放使用","用胶带缠绕灯头后发放使用","让使用人员自行配密封圈"],"answer":[0],"explanation":"知识点：矿灯完好标准。灯头密封圈缺失会使矿灯失去防爆性能，属于不完好矿灯，严禁发放使用。灯亮不代表防爆合格；胶带缠绕不能恢复密封性能；使用人员自行配圈不符合管理要求。"},{"id":237,"type":"single","stem":"安全检查工在皮带运输巷发现输送带跑偏并摩擦机架，最应优先采取的处置是","options":["停机并通知维修人员调整托辊","向跑偏侧加装挡煤板继续运行","降低带速后继续观察运行","安排人员在运行中用手推正输送带"],"answer":[0],"explanation":"知识点：输送带跑偏摩擦的危害。跑偏摩擦机架可能磨断输送带或产生火花，应先停机再调整。加挡煤板、降速观察都不能消除摩擦；运行中用手推带极易造成人员伤害。"},{"id":238,"type":"single","stem":"井下爆破作业中，安全检查工发现爆破工准备在瓦斯浓度1.2%的地点装药，正确处置是","options":["制止装药，待瓦斯浓度降至规定以下再作业","允许装药但要求减少装药量","允许装药但要求加快爆破速度","要求爆破工佩戴自救器后继续装药"],"answer":[0],"explanation":"知识点：爆破地点的瓦斯浓度要求。瓦斯超限时严禁装药爆破，必须停止作业、加强通风，待浓度降至规定值以下方可进行。减少药量、加快速度、佩戴自救器都不能消除瓦斯爆炸风险。"},{"id":239,"type":"single","stem":"煤矿井下安全避险系统中，为灾变时人员提供呼吸保护的设施是","options":["压风自救装置","供水施救装置","通信联络系统","人员定位系统"],"answer":[0],"explanation":"知识点：井下安全避险六大系统功能。压风自救装置在灾变时向人员提供新鲜空气，属于呼吸保护设施。供水施救装置提供饮用水，通信联络用于信息传递，人员定位用于掌握人员位置，均不提供呼吸保护。"},{"id":240,"type":"single","stem":"井下安全检查中，用光学瓦斯检定器测定甲烷浓度时，若干涉条纹的黑基线对准整数位后微调螺旋，黑基线应调到哪条条纹再读数","options":["对准整数位条纹后直接读数","对准两条条纹中间后读数","对准最亮条纹后读数","对准分划板零位后读数"],"answer":[1],"explanation":"知识点：光学瓦斯检定器读数方法。正确项：微调螺旋使黑基线对准两条条纹中间，可减小估读误差。A项对准整数位会丢掉小数部分；C项最亮条纹并非读数基准；D项零位是调零时用的基准，不是测定读数位置。"},{"id":241,"type":"single","stem":"煤矿井下采掘工作面回风流中甲烷浓度达到多少时，必须停止工作、撤出人员并切断电源","options":["0.5%","0.8%","1.0%","1.5%"],"answer":[3],"explanation":"知识点：采掘工作面回风流甲烷断电浓度。正确项：回风流甲烷达到1.5%时必须停止工作、撤人、断电。A项0.5%是采掘工作面进风流限制；B项0.8%接近采区回风限制；C项1.0%是采掘工作面风流中报警浓度。"},{"id":242,"type":"single","stem":"安全检查员在井下发现局部通风机风筒脱节，工作面风量明显不足，瓦斯浓度尚未超限，最先应当做的是","options":["立即停止工作面作业并撤出人员","记录后交班时汇报通风部门","现场动手把风筒接好恢复供风","通知电工停掉工作面设备电源"],"answer":[0],"explanation":"知识点：通风异常应急处置顺序。正确项：风量不足有瓦斯积聚风险，先停止作业撤人，再汇报处理。B项拖延处理会扩大风险；C项检查员不负责现场接风筒，且未排除瓦斯前恢复供风有风险；D项只断电不撤人，人员仍在危险区域。"},{"id":243,"type":"single","stem":"安全检查员测定巷道风流中二氧化碳浓度时，使用光学瓦斯检定器应如何操作","options":["直接读取甲烷刻度即为二氧化碳浓度","加装钠石灰管后读取的差值即为二氧化碳浓度","抽气后读取最大条纹位置即为二氧化碳浓度","先测混合气体再测甲烷，两次读数之差即为二氧化碳浓度"],"answer":[3],"explanation":"知识点：光学检定器测二氧化碳的差减法。正确项：先测混合气体浓度，再通过钠石灰吸收二氧化碳后测甲烷，两次读数之差为二氧化碳浓度。A项混淆了两种气体刻度；B项钠石灰管是吸收二氧化碳的，不是加装后直接读差值；C项最大条纹位置不是浓度读数依据。"},{"id":244,"type":"single","stem":"安全检查员进入盲巷检查前，首先必须确认的条件是","options":["盲巷内支护完好无片帮","盲巷内瓦斯和氧气浓度符合规定","盲巷内无积水无杂物","盲巷口设有警示标志"],"answer":[1],"explanation":"知识点：盲巷检查安全条件。正确项：盲巷易积聚瓦斯和缺氧，进入前必须确认气体浓度合格。A项支护完好是次要条件；C项积水杂物与中毒窒息风险无关；D项警示标志是管理措施，不能替代气体检测。"},{"id":245,"type":"single","stem":"井下安全检查中发现某处风门同时打开造成风流短路，检查员应当","options":["随手把风门关好并继续巡检","立即汇报并追查责任班组","现场纠正后记录并汇报通风部门","等通风部门巡检时自行处理"],"answer":[2],"explanation":"知识点：通风设施隐患处置。正确项：检查员应现场纠正并记录汇报，由通风部门落实整改。A项随手关好未记录，隐患未闭环；B项只汇报不纠正，风流短路持续存在；D项放任不管属失职。"},{"id":246,"type":"single","stem":"煤矿井下采用局部通风机供风时，风筒出口到掘进工作面的距离应当","options":["不大于5米","不大于10米","不大于15米","不大于20米"],"answer":[1],"explanation":"知识点：掘进工作面风筒出口距工作面距离要求。正确项：风筒出口距掘进工作面不得大于10米，保证有效通风。A项5米过严，实际规定为不大于10米；C项15米、D项20米均超过规定，易造成工作面供风不足。"},{"id":247,"type":"single","stem":"安全检查员在井下发现电缆与水管悬挂在同一侧且相互接触，正确的判断是","options":["属于正常布置，无需处理","电缆应悬挂在水管上方并保持间距","电缆应悬挂在水管下方并保持间距","电缆与水管可同侧悬挂但须用绝缘物隔开"],"answer":[1],"explanation":"知识点：井下电缆悬挂要求。正确项：电缆应悬挂在水管上方并保持规定间距，防止水管漏水影响电缆。A项接触悬挂属隐患；C项悬挂在下方更易受潮受损；D项同侧悬挂的隔离方式不符合规程要求。"},{"id":248,"type":"single","stem":"某掘进工作面安全检查时发现瓦斯监控系统显示断线，但工作面瓦斯浓度正常，检查员下一步应当","options":["继续作业，等监控系统恢复","停止掘进作业并汇报处理","用便携仪替代监控继续作业","记录后交班时再汇报"],"answer":[1],"explanation":"知识点：安全监控系统故障处置。正确项：监控断线即失去连续监测，应停止作业并汇报处理。A项无监控作业违章；C项便携仪不能替代监控系统连续监测功能；D项拖延汇报使作业处于无监控状态。"},{"id":249,"type":"single","stem":"煤矿井下检查中发现局部通风机风筒末端距掘进工作面超过作业规程规定距离，且工作面瓦斯浓度0.8%，检查员应首先采取的措施是","options":["责令现场立即停止作业撤出人员并切断电源","要求班组先接长风筒再恢复作业并记录问题","通知通风部门次日调整风筒并在班后汇报","同意作业但限定一小时内完成接风筒工作"],"answer":[0],"explanation":"知识点：瓦斯超限与风筒距离超限属重大隐患，必须先停止作业撤人断电。正确项对在消除直接危险源、防止瓦斯继续积聚并避免电气火花引爆。错误项错在：先接风筒再作业属边生产边整改；次日调整放任隐患过夜；限时作业仍允许人员在危险状态下作业。"},{"id":250,"type":"single","stem":"煤矿安全规程对井下主要排水泵房工作水泵能力的要求是能在多少小时内排出矿井24小时正常涌水量","options":["20小时","24小时","16小时","12小时"],"answer":[0],"explanation":"知识点：工作水泵能力应在20小时内排出矿井24小时正常涌水量。正确项符合规程对排水能力的底线要求。错误项错在：24小时仅为平衡值不具备储备能力；16小时和12小时高于规定，属把备用与工作能力混淆的常见误记。"},{"id":251,"type":"single","stem":"井下检查时发现某处密闭墙前有轻微瓦斯涌出且墙体出现新裂缝，检查员判断该处最可能存在的隐患是","options":["采空区瓦斯通过裂隙向外泄漏","密闭墙内积水压力导致渗水","巷道变形引起墙体表面碳化","密闭墙内温度下降造成负压"],"answer":[0],"explanation":"知识点：密闭墙裂缝伴随瓦斯涌出指向采空区瓦斯外泄隐患。正确项对在瓦斯涌出与裂缝并存是采空区气体外泄的典型特征。错误项错在：积水压力主要表现渗水而非瓦斯；碳化是材料老化不是涌出原因；温度下降不会造成负压泄漏。"},{"id":252,"type":"single","stem":"煤矿井下爆破作业执行“一炮三检”时，检查员发现装药前瓦斯浓度0.9%、爆破前瓦斯浓度1.1%，正确处置是","options":["停止爆破并撤人，待瓦斯降至规定值以下再处理","加强通风5分钟后继续装药并准备起爆","只在爆破前再测一次，合格即可起爆","降低装药量后直接起爆以减少瓦斯涌出"],"answer":[0],"explanation":"知识点：爆破前瓦斯浓度超过1.0%严禁爆破。正确项对在1.1%已超限，必须停止爆破撤人并处理。错误项错在：短时通风未确认降到规定值；只测一次规避了装药前检查；减药量不能改变瓦斯超限事实。"},{"id":253,"type":"single","stem":"井下安全检查发现某掘进工作面风筒有一处破口漏风，且工作面回风流瓦斯浓度0.7%，检查员应要求","options":["立即修补或更换风筒并复查风量与瓦斯","暂时用风筒布遮挡破口后继续掘进","加大局部通风机功率即可不处理破口","将该处列入下周检修计划并正常作业"],"answer":[0],"explanation":"知识点：风筒漏风会降低工作面有效风量，属必须及时处理的隐患。正确项对在修补更换并复查可恢复有效通风。错误项错在：遮挡不能恢复风量且属临时凑合；加大功率不解决漏风且可能超负荷；列入下周计划放任隐患持续。"},{"id":254,"type":"single","stem":"煤矿井下使用的电气设备检查中，发现隔爆外壳紧固螺栓缺失一颗，其余螺栓齐全，正确处置是","options":["停止该设备运行并补齐螺栓后才可恢复","用同规格普通螺栓临时替代后继续运行","减少该设备负荷运行至检修班再补螺栓","在缺失处加装垫片压紧后继续运行"],"answer":[0],"explanation":"知识点：隔爆外壳紧固螺栓缺失会破坏隔爆性能，属失爆。正确项对在必须停止运行并补齐合格螺栓。错误项错在：普通螺栓不具隔爆要求；减负荷不恢复隔爆性能；加垫片不能代替缺失螺栓且可能破坏密封。"},{"id":255,"type":"single","stem":"井下检查时发现某处电缆与压风管同侧吊挂且间距不足，检查员判定该隐患的主要风险是","options":["电缆受机械损伤或管路漏气引发事故","电缆载流量下降导致过热","压风管内压力波动影响电缆绝缘","管路振动造成电缆信号干扰"],"answer":[0],"explanation":"知识点：电缆与管路间距不足易受机械损伤或管路泄漏冲击。正确项对在间距不足的直接风险是机械损伤与漏气引发事故。错误项错在：载流量与间距无关；压力波动不直接破坏绝缘；信号干扰不是主要安全风险。"},{"id":256,"type":"single","stem":"井下检查发现某采煤工作面上下出口高度低于作业规程规定，且出口处有片帮迹象，正确处置是","options":["停止作业，先处理片帮并恢复出口高度","设置警示标志后继续生产至班末","安排人员从出口快速通过并加强观察","仅记录问题，交由下一班处理"],"answer":[0],"explanation":"知识点：安全出口高度不足且片帮属重大隐患，必须停止作业处理。正确项对在消除片帮并恢复出口高度。错误项错在：设标志继续生产放任隐患；快速通过不能消除危险；交下班处理使人员持续处于危险中。"},{"id":257,"type":"single","stem":"煤矿井下瓦斯检查中，使用光学甲烷检测仪前必须进行的操作是","options":["在新鲜风流中清洗气室并校对零位","在待测地点直接调零后读数","用嘴吹气检查气路是否通畅","将仪器倒置排出内部积水"],"answer":[0],"explanation":"知识点：光学甲烷检测仪使用前应在新鲜风流中清洗气室并校对零位。正确项对在保证测量基准准确。错误项错在：待测地点调零会把瓦斯当零位；嘴吹气不属规范操作；倒置排水会损坏仪器且不解决校准。"},{"id":258,"type":"single","stem":"井下检查发现某处局部通风机发生循环风，工作面瓦斯浓度有上升趋势，正确处置是","options":["立即停止掘进，调整风筒与风机位置消除循环风","保持掘进并加大风机功率抵消循环风","将风机移至巷道另一侧后继续作业","减少工作面人员后维持掘进观察瓦斯变化"],"answer":[0],"explanation":"知识点：循环风会导致瓦斯积聚，必须停止作业并消除循环风。正确项对在停止掘进并调整风筒风机位置。错误项错在：加大功率不能消除循环风；移风机不调整风筒仍可能循环；减人不能改变瓦斯上升趋势。"},{"id":259,"type":"single","stem":"井下安全检查工在采煤工作面发现局部瓦斯浓度达到1.2%且仍在缓慢上升，此时最应优先采取的措施是","options":["通知采煤机司机降低牵引速度继续作业","撤出人员并切断工作面电源","开启工作面回风巷的净化水幕降尘","记录数据后等下一班再统一上报"],"answer":[1],"explanation":"知识点：瓦斯超限应急处置。瓦斯浓度达到1.0%即须停止用电、撤人、断电，1.2%仍在上升说明有持续涌出源，必须先撤人断电。降低牵引速度不能消除超限风险，属于冒险作业；开启水幕只能降尘不能降瓦斯；等下一班上报会延误处置时机。"},{"id":260,"type":"single","stem":"检查井下局部通风机时，发现风筒末端距掘进工作面迎头距离超过作业规程规定，但风筒连接完好无破口，正确的判定是","options":["风筒完好即视为通风合格","属于通风距离不符合规定的隐患","只需补挂一节短风筒即可","待放炮后再调整风筒位置"],"answer":[1],"explanation":"知识点：局部通风质量检查。风筒末端到迎头的距离是作业规程明确规定的参数，超距会导致迎头风量不足、瓦斯积聚，属通风隐患。风筒完好不等于通风合格，超距本身就是问题；补短风筒和放炮后调整都不能代替立即停止作业并整改。"},{"id":261,"type":"single","stem":"安检工在井下巷道行走时闻到轻微的类似臭鸡蛋气味，且同行人员表示并无异常设备报警，正确的处置是","options":["继续前行并留意气味是否变浓","立即沿最短路线逆风撤出并报告","原地停留观察气味来源方向","用湿毛巾捂住口鼻后继续检查"],"answer":[1],"explanation":"知识点：硫化氢识别与自救。臭鸡蛋气味是硫化氢的典型特征，硫化氢剧毒且比空气重，应逆风、沿最短安全路线迅速撤出并报告。继续前行或原地观察都会接近或停留在危险区；湿毛巾不能有效过滤硫化氢，不能作为继续作业的依据。"},{"id":262,"type":"single","stem":"检查采煤工作面液压支架时，发现个别支架初撑力不足，正确判断其危害是","options":["仅影响支架外观整齐度","易造成顶板离层和漏冒","只增加乳化液消耗量","会降低采煤机截割效率"],"answer":[1],"explanation":"知识点：支护质量与顶板管理。初撑力不足使支架不能及时支撑顶板，导致顶板离层、下沉甚至漏冒。外观整齐度、乳化液消耗、截割效率都不是初撑力不足的核心危害。"},{"id":263,"type":"single","stem":"井下安全检查中发现某处电缆与水管同侧吊挂且间距偏小，正确的隐患定性是","options":["电缆吊挂属于临时性工程可不考核","电缆与管路间距不足可能导致绝缘受损","水管漏水会冲走电缆表面煤尘","电缆发热会提高管内水温"],"answer":[1],"explanation":"知识点：井下电缆敷设安全要求。电缆与管路应保持规定间距，间距不足会因管路检修、振动、漏水等造成电缆绝缘受损甚至短路。临时性工程不是免检理由；冲走煤尘、提高水温均非主要安全风险。"},{"id":264,"type":"single","stem":"对井下电气设备进行防爆性能检查时，发现隔爆外壳紧固螺栓缺失一只，其余螺栓齐全，正确的处理是","options":["用同规格铁丝临时绑扎代用","立即停止使用并按规定处理","在缺失处涂防爆胶泥封堵","降低该设备负荷后继续运行"],"answer":[1],"explanation":"知识点：隔爆电气设备失爆判定。隔爆外壳紧固螺栓缺失即构成失爆，必须立即停止使用并按规定处理。铁丝绑扎、涂胶泥、降负荷运行都不能恢复隔爆性能。"},{"id":265,"type":"single","stem":"井下安全检查工在爆破作业前进行现场检查，发现警戒线设置位置符合规定但警戒人员尚未到位，正确的处置是","options":["由安检工代替警戒人员站岗","立即制止起爆并待警戒到位","缩短警戒距离后即可起爆","待爆破工鸣哨后自行补位"],"answer":[1],"explanation":"知识点：爆破警戒与起爆条件。所有警戒人员到位并确认无误后方可起爆，警戒人员未到位即不具备起爆条件。安检工不能代替警戒人员；缩短警戒距离违反规定；鸣哨后补位为时已晚。"},{"id":266,"type":"single","stem":"检查矿井主要通风机运行记录时，发现通风机刚发生一次无计划停风，恢复通风前必须优先完成的工作是","options":["直接启动通风机恢复全矿通风","检查瓦斯并按规定排放积聚瓦斯","通知采区恢复生产准备","先开启局部通风机吹散迎头瓦斯"],"answer":[1],"explanation":"知识点：停风后恢复通风程序。主要通风机停风后，井下可能积聚瓦斯，恢复通风前必须先检查瓦斯并按措施排放。直接启动、通知恢复生产、先开局部通风机都可能因风流短路或瓦斯排放失控造成事故。"},{"id":267,"type":"single","stem":"安检工在掘进工作面发现风筒有一处约拳头大小的破口，漏风明显，现场最恰当的处置是","options":["用风筒布贴补后继续掘进","立即停止作业并通知修补风筒","把破口处折叠后用绳扎紧","将局部通风机风量调大补偿漏风"],"answer":[1],"explanation":"知识点：局部通风设施管理。风筒破口漏风会减少迎头有效风量，应停止作业并按要求修补。贴补、折叠扎紧均属临时凑合且难以保证密封；调大风量不能代替修补，还可能掩盖其他问题。"},{"id":268,"type":"single","stem":"井下安全检查中，发现一名工人未按规定佩戴隔离式自救器，而携带的是过滤式自救器进入采煤工作面，正确的判定是","options":["过滤式自救器在采煤工作面可正常使用","采煤工作面应使用隔离式自救器","只要自救器在有效期内即可使用","由班组长决定使用哪种自救器"],"answer":[1],"explanation":"知识点：自救器选用。采煤工作面存在瓦斯和煤尘爆炸风险，可能产生高浓度一氧化碳并缺氧，应使用隔离式自救器。过滤式自救器不适用于此类环境；有效期和班组长决定都不能改变选型错误。"},{"id":269,"type":"single","stem":"井下安全检查工在巡查时发现某处盲巷未按规定设置栅栏和警示标志，现场正确处置是","options":["记录后交由下一班处理","立即停止人员进入并督促设置栅栏警示","在盲巷口悬挂一块写有名称的牌板","用木板临时挡住巷口即可"],"answer":[1],"explanation":"知识点：盲巷管理。盲巷易积聚瓦斯等有害气体，必须设置栅栏和警示标志，禁止人员进入。记录移交、仅挂牌板、木板临时遮挡都不能起到有效隔离和警示作用。"},{"id":270,"type":"single","stem":"井下巷道内检查时发现顶板有少量淋水且水质清澈，检查人员下一步应优先采取的措施是","options":["记录淋水位置并继续向前检查其他区域","立即撤出该区域人员并设置警戒","用工具敲击淋水处顶板听声音判断","取水样送地面化验确定水源"],"answer":[1],"explanation":"知识点：顶板淋水是突水或冒顶的常见前兆，安全检查作业要求发现异常先撤人警戒。清澈淋水也可能来自含水层或老空水，不能仅凭水质判断安全。撤人警戒是首要处置；A 继续检查忽视风险；C 敲击帮顶听音是辅助手段，不能替代撤人；D 化验是后续工作，不能先于撤人。"},{"id":271,"type":"single","stem":"煤矿安全检查工在采煤工作面检查瓦斯时，正确使用光学甲烷检测仪的做法是","options":["在巷道回风侧靠近顶板处读取最高值","在风流稳定处用仪器对风流直接读数","把仪器伸入采空区边缘连续检测三次","在支架间靠近底板处读取最低值"],"answer":[0],"explanation":"知识点：瓦斯比空气轻，易积聚在顶板附近和回风侧，检测应选最高浓度位置。A 正确，回风侧靠近顶板读数能反映真实最高浓度；B 风流稳定处读数偏低不代表危险点；C 采空区边缘不是常规检测点且连续三次无规范依据；D 底板处甲烷浓度低，读数无代表性。"},{"id":272,"type":"single","stem":"井下检查时发现局部通风机停止运转，停风区域甲烷浓度达到 1.5%，检查人员正确处置是","options":["立即启动局部通风机恢复通风","切断停风区域电源并撤出人员","安排人员在原地等待风机自动恢复","打开风门利用自然风压稀释瓦斯"],"answer":[1],"explanation":"知识点：停风区域瓦斯超限时严禁直接启动风机，防止排出高浓度瓦斯经过电气设备引发爆炸。B 正确，先断电撤人；A 直接启动风机可能造成瓦斯流经火源；C 原地等待不消除风险；D 自然风压不可控，不能替代断电撤人。"},{"id":273,"type":"single","stem":"煤矿井下安全检查作业中，对爆破后工作面进行安全检查的进入时机是","options":["爆破后立即进入查看爆破效果","等待炮烟吹散且通风正常后进入","听到炮响后 5 分钟准时进入","由爆破工确认无盲炮后进入"],"answer":[1],"explanation":"知识点：爆破后炮烟含大量有毒有害气体，必须待炮烟稀释吹散、通风恢复正常后方可进入检查。B 正确；A 立即进入会中毒或缺氧；C 固定 5 分钟不以炮烟吹散和通风为准；D 爆破工确认无盲炮不能替代炮烟吹散与通风恢复条件。"},{"id":274,"type":"single","stem":"井下检查发现一氧化碳检测仪读数持续升高而甲烷浓度正常，检查人员应首先判断的异常类型是","options":["瓦斯突出前兆","煤层自燃或火灾征兆","顶板来压前兆","通风机故障停风"],"answer":[1],"explanation":"知识点：一氧化碳持续升高而甲烷正常，是煤炭自燃或火灾的典型标志。B 正确；A 瓦斯突出前兆以瓦斯涌出异常为主；C 顶板来压以片帮、掉渣、支架变形为主；D 风机停风会导致多种气体变化且甲烷通常也会升高。"},{"id":275,"type":"single","stem":"煤矿安全检查工在检查主要通风机时，发现风机运转声音异常且电流波动较大，正确处置是","options":["记录后继续检查其他设备","立即报告并联系停机检查","调整风叶角度降低负荷","切换备用风机后不再处理"],"answer":[1],"explanation":"知识点：主要通风机异常可能引发全矿通风系统紊乱，必须立即报告并停机检查。B 正确；A 拖延可能造成事故；C 擅自调整风叶角度会改变矿井风量分配；D 切换备用风机后仍需处理故障风机，不能搁置。"},{"id":276,"type":"single","stem":"井下检查时发现电气设备外壳带电且有人可能接触，检查人员的首要处置是","options":["用绝缘工具拉开上级电源开关","用干木棍将设备与人员分离","立即用手拉拽触电人员","通知电工到现场后再处理"],"answer":[0],"explanation":"知识点：发现触电或设备带电，首要措施是尽快切断电源。A 正确，用绝缘工具拉闸断电；B 分离设备是断电后的辅助手段且顺序颠倒；C 直接用手拉拽会导致自身触电；D 等待电工延误抢救时机。"},{"id":277,"type":"single","stem":"煤矿安全检查作业中，检查采空区密闭墙时发现墙前瓦斯浓度 2.0%，正确做法是","options":["打开密闭墙检查内部情况","在墙外加强通风降低浓度","撤出人员并报告处理","用黄泥临时封堵裂缝"],"answer":[2],"explanation":"知识点：密闭墙前瓦斯超限说明采空区瓦斯外泄，有爆炸危险，应撤人报告。C 正确；A 打开密闭墙会使大量瓦斯涌出；B 墙外通风不能消除采空区内部瓦斯；D 封堵裂缝不能解决瓦斯积聚且可能因工具碰撞产生火花。"},{"id":278,"type":"single","stem":"井下安全检查发现风门被矿车撞坏无法正常关闭，对通风系统的主要影响是","options":["局部风量减少","风流短路或反向","瓦斯浓度自动降低","粉尘浓度升高"],"answer":[0],"explanation":"知识点：风门损坏导致漏风，使用风地点风量减少。A 正确；B 风流短路或反向需特定条件，单纯风门损坏主要造成漏风；C 瓦斯浓度不会自动降低；D 粉尘浓度与风门损坏无直接必然联系。"},{"id":279,"type":"single","stem":"煤矿安全检查工在井下发现有人违章带电检修电气设备，正确处置顺序是","options":["先制止并断电，再报告并记录","先记录违章行为，再通知电工","先帮助完成检修，再向上报告","先拍照取证，再等待其自行停止"],"answer":[0],"explanation":"知识点：发现带电检修必须立即制止并切断电源，消除危险后再报告记录。A 正确；B 只记录不制止危险持续；C 协助违章会扩大风险；D 等待自行停止延误处置。"},{"id":280,"type":"single","stem":"井下安全检查中，测定巷道风量的正确操作是","options":["在巷道拐弯处用风表直接读数","在测风站内按断面法往返测量取平均","在风门附近用手感受风速估算","在支架间测量局部风速代替全断面"],"answer":[1],"explanation":"知识点：测风应在专门测风站内，按断面法往返测量取平均，保证数据准确。B 正确；A 拐弯处风流紊乱不具代表性；C 手感估算误差大；D 局部风速不能代表全断面平均风速。"},{"id":281,"type":"single","stem":"煤矿井下检查时发现采煤工作面回风巷瓦斯浓度达到1.2%，现场应采取的处置措施是","options":["停止工作面作业并切断电源撤出人员","继续作业但加强通风降低浓度","安排瓦检员现场监测后维持生产","通知班组长后等待调度指令"],"answer":[0],"explanation":"知识点：瓦斯浓度超限处置。回风巷瓦斯浓度达到1.0%即超限，1.2%已超限，必须停止作业、切断电源、撤出人员。错误项：继续作业属冒险生产；现场监测不能替代撤人；等待指令延误处置时机。"},{"id":282,"type":"single","stem":"煤矿安全检查工在检查局部通风机时，发现风筒末端距掘进工作面距离超过作业规程规定，正确的判定是","options":["属通风管理隐患，应责令立即整改","属正常现象，无需处理","属设备故障，由机电部门处理","属瓦斯隐患，直接停止全矿生产"],"answer":[0],"explanation":"知识点：局部通风管理。风筒末端距工作面距离超规定属通风隐患，应责令整改。错误项：正常现象判断错误；该问题属通风管理非机电设备故障；仅局部问题不需全矿停产。"},{"id":283,"type":"single","stem":"井下检查时发现某处巷道顶板出现新裂缝并伴有轻微掉渣，安全检查工的首要处置是","options":["立即撤出该区域人员并设置警戒","用木料临时支护后继续观察","记录裂缝位置后继续巡查其他区域","通知班长安排人员清理掉渣"],"answer":[0],"explanation":"知识点：顶板事故预兆处置。新裂缝伴掉渣是冒顶前兆，首要撤人并警戒。错误项：临时支护不能先于撤人；记录后继续巡查忽视风险；清理掉渣未撤人属危险作业。"},{"id":284,"type":"single","stem":"煤矿安全检查作业中，对井下电气设备进行防爆检查时，发现隔爆外壳结合面有油漆覆盖，正确的判定是","options":["属失爆隐患，应停止使用并处理","属正常保护，不影响防爆性能","属外观问题，下次检修再处理","属机电隐患，由电工现场擦拭即可"],"answer":[0],"explanation":"知识点：隔爆设备失爆判定。结合面油漆影响隔爆性能，属失爆。错误项：油漆不能保护隔爆面；外观问题说法掩盖失爆本质；现场擦拭未按失爆程序处理。"},{"id":285,"type":"single","stem":"煤矿井下发生火灾时，安全检查工在火势较小且具备条件的情况下，应优先采取的处置是","options":["使用现场灭火器材直接扑灭","立即撤离并等待救护队","先切断全矿电源再灭火","打开风门增加通风后灭火"],"answer":[0],"explanation":"知识点：井下火灾初期处置。火势小且具备条件时应直接扑灭。错误项：等待救护队错失初期灭火时机；切断全矿电源影响范围过大；打开风门可能助长火势。"},{"id":286,"type":"single","stem":"检查井下运输巷道时，发现轨道接头间隙明显超过规定值，正确的判定是","options":["属运输隐患，应安排整改","属正常磨损，可继续使用","属轨道质量问题，由供应部门处理","属轻微缺陷，月底检修处理"],"answer":[0],"explanation":"知识点：轨道运输安全检查。接头间隙超规定属隐患应整改。错误项：正常磨损说法错误；供应部门不负责现场隐患；月底处理延误整改。"},{"id":287,"type":"single","stem":"安全检查工在采煤工作面检查时，发现支柱初撑力普遍不足，正确的处置是","options":["责令立即补液并重新检查确认","记录后由下一班处理","安排人员增加支柱数量","通知采煤机司机降低割煤速度"],"answer":[0],"explanation":"知识点：支护质量检查。初撑力不足应责令立即补液并复查。错误项：交下班处理延误；增加数量不解决初撑力；降低割煤速度与支护质量无直接关系。"},{"id":288,"type":"single","stem":"井下检查发现某掘进工作面未按规定执行\"有掘必探\"，安全检查工应","options":["立即责令停止掘进并报告","要求补做钻探后继续掘进","记录后由地质部门补探","允许掘进但控制进尺速度"],"answer":[0],"explanation":"知识点：防治水\"有掘必探\"原则。未执行必须停止掘进并报告。错误项：补探后继续仍违规；地质部门补探不能替代停工；控制进尺不能消除突水风险。"},{"id":289,"type":"single","stem":"煤矿安全检查工在井下发现一氧化碳浓度异常升高但未见明火，正确的判断是","options":["可能存在隐蔽火源，应立即报告并撤人","属正常现象，继续观察即可","属爆破后残留气体，通风后正常","属检测仪故障，更换仪器再测"],"answer":[0],"explanation":"知识点：一氧化碳异常与隐蔽火源。CO异常升高无明火可能为隐蔽火源，应报告撤人。错误项：正常现象判断错误；爆破后气体有特定时间规律；未复测即归因仪器武断。"},{"id":290,"type":"single","stem":"安全检查工在井下陪同检查时，发现某区域瓦斯传感器被煤尘覆盖且显示数据长期不变，正确的处置是","options":["责令立即清理并校验传感器","用嘴吹去煤尘后继续使用","记录后由监控部门远程处理","暂时忽略，待检修班处理"],"answer":[0],"explanation":"知识点：安全监控系统检查。传感器被覆盖数据失真，应清理并校验。错误项：吹去煤尘不规范且未校验；远程处理不能解决现场覆盖；待检修班处理延误。"},{"id":291,"type":"multi","stem":"煤矿安全检查工在对井下爆破作业进行安全检查时，下列属于必须立即制止的违章行为有","options":["爆破母线长度不足规定值","爆破前未检查瓦斯浓度","爆破后未等待规定时间进入检查","使用专用发爆器起爆","爆破地点20米内未清除杂物"],"answer":[0,1,2],"explanation":"知识点：爆破安全规程。母线不足、未检瓦斯、未等待进入均属必须制止的违章。错误项：使用专用发爆器是正确做法；20米内未清除杂物属应整改但不属立即制止的爆破违章。"},{"id":292,"type":"single","stem":"煤矿井下安全检查中，发现采煤工作面回风隅角瓦斯浓度达到1.2%时，安全检查人员应当采取的处置措施是","options":["责令现场作业人员立即停止作业并切断电源撤出人员","要求作业人员加强通风后继续观察瓦斯变化情况","安排瓦斯检查工在现场持续监测并正常组织生产","通知班组长加强洒水降尘后恢复采煤作业"],"answer":[0],"explanation":"知识点：采掘工作面回风隅角瓦斯浓度达到1.0%即为超限，必须停止作业、切断电源、撤出人员。正确项对：瓦斯超限必须立即停止作业并撤人断电，这是防止瓦斯爆炸的基本处置程序。错误项1错在通风后观察期间仍可能达到爆炸条件，不能继续作业；错误项2错在超限状态下不得正常组织生产；错误项3错在洒水降尘与瓦斯超限处置无关，不能替代停电撤人。"},{"id":293,"type":"single","stem":"煤矿安全检查人员对井下局部通风机进行现场检查时，发现风筒末端距掘进工作面迎头距离超过作业规程规定，正确的判断是","options":["属于风筒吊挂质量问题，不影响有效风量可暂不处理","属于通风管理隐患，应责令立即整改并重新接设风筒","属于机电设备隐患，应移交机电部门按设备缺陷处理","属于工程质量问题，应在当班验收时统一安排处理"],"answer":[1],"explanation":"知识点：风筒末端到掘进工作面迎头的距离超过规定，会导致迎头有效风量不足、瓦斯积聚，属于通风管理隐患。正确项对：应立即责令整改并重新接设风筒，保证迎头有效通风。错误项1错在末端距离超限直接影响有效风量，不是吊挂外观问题；错误项2错在风筒属于通风设施，不是机电设备缺陷；错误项3错在通风隐患必须立即处理，不能等当班验收时统一安排。"},{"id":294,"type":"single","stem":"安全检查人员在井下检查带式输送机时，发现输送带跑偏严重且摩擦托辊出现烟雾，正确的首要处置是","options":["立即停机并汇报调度室，查明原因后组织处理","降低带速继续运行，待检修班再调整托辊位置","用水管直接向摩擦部位浇水降温后维持运转","安排专人在跑偏段监护，运行到本班结束再停机"],"answer":[0],"explanation":"知识点：带式输送机跑偏摩擦产生烟雾是火灾前兆，必须立即停机处理。正确项对：立即停机并汇报调度室，防止摩擦升温引燃输送带或煤尘。错误项1错在降低带速不能消除摩擦热源，仍可引燃；错误项2错在井下带电摩擦部位直接浇水可能引发触电或扩大事故；错误项3错在专人监护不能阻止摩擦持续升温，属于冒险运行。"},{"id":295,"type":"single","stem":"煤矿安全检查作业人员进入井下进行检查前，对随身携带的甲烷检测仪应当完成的操作是","options":["检查外观完好后直接带入井下使用","在井口新鲜风流中校零并确认报警功能正常","到井下作业地点后再开机预热并校准","由瓦斯检查工代为检查后即可带入使用"],"answer":[1],"explanation":"知识点：便携式甲烷检测仪入井前必须在新鲜风流中校零并确认报警功能，保证检测数据准确。正确项对：井口新鲜风流中校零并验证报警功能是入井前的必要程序。错误项1错在只查外观不能保证检测精度和报警功能；错误项2错在井下作业地点空气中可能含瓦斯，无法完成准确校零；错误项3错在检查人员应自行确认仪器状态，不能仅凭他人代查。"},{"id":296,"type":"single","stem":"煤矿井下安全检查中发现掘进工作面瓦斯涌出异常增大，安全检查人员的正确做法是","options":["立即责令停止作业、撤出人员并报告调度室","要求增加风筒数量后继续掘进作业","安排人员加密瓦斯检查次数并维持正常生产","通知瓦检工加大检查力度后按原计划施工"],"answer":[0],"explanation":"知识点：瓦斯涌出异常增大是突出或积聚的前兆，必须停止作业、撤出人员并汇报。正确项对：立即停止作业撤人并报告调度室，防止瓦斯事故。错误项1错在增加风筒不能消除异常涌出根源，继续掘进冒险；错误项2错在加密检查不能替代停止作业撤人；错误项3错在维持正常生产违反瓦斯异常处置要求。"},{"id":297,"type":"single","stem":"安全检查人员检查井下电气设备时，发现开关腔体内有弧光痕迹和烧焦气味，正确的判断与处置是","options":["属于设备外观缺陷，记录后待停产检修时处理","属于失爆隐患，应立即停止使用并安排检修","属于正常磨损现象，清理腔体后可继续使用","属于电缆故障，应更换电缆后恢复送电"],"answer":[1],"explanation":"知识点：隔爆开关腔体内出现弧光痕迹和烧焦气味，说明内部可能已发生闪络或绝缘损坏，存在失爆风险。正确项对：应立即停止使用并安排检修，防止引发瓦斯煤尘爆炸。错误项1错在失爆隐患不能等停产检修时处理；错误项2错在弧光痕迹不是正常磨损，清理后仍可能失爆；错误项3错在故障在开关腔体内，更换电缆不能消除失爆隐患。"},{"id":298,"type":"single","stem":"煤矿井下发生瓦斯爆炸事故后，安全检查人员配合应急处置时，对灾区人员的正确做法是","options":["组织人员佩戴自救器沿进风巷道撤出灾区","组织人员逆着烟雾方向穿过灾区寻找出口","安排人员在原地等待救援人员到达后再撤离","组织人员进入盲巷躲避爆炸冲击波和火焰"],"answer":[0],"explanation":"知识点：瓦斯爆炸后灾区人员应佩戴自救器沿进风巷道撤离，避免进入盲巷或逆烟流行动。正确项对：沿进风巷道撤出可避开有毒有害气体和火焰，是最安全的撤离路线。错误项1错在逆烟雾穿越灾区会吸入大量CO等有毒气体；错误项2错在原地等待会持续受有毒气体威胁；错误项3错在盲巷可能积聚瓦斯和有毒气体，进入盲巷极其危险。"},{"id":299,"type":"single","stem":"安全检查人员在检查采煤工作面液压支架时，发现支架初撑力普遍低于作业规程规定值，正确的处置意见是","options":["属于支架操作问题，要求移架时提高初撑力即可","属于顶板管理隐患，应责令停止作业并整改后再生产","属于设备老化问题，应待支架大修时统一处理","属于正常压力波动，加强矿压观测后可继续生产"],"answer":[1],"explanation":"知识点：液压支架初撑力普遍不足会导致顶板下沉、离层，属于顶板管理重大隐患。正确项对：应责令停止作业并整改，恢复初撑力后方可生产。错误项1错在初撑力不足是系统性问题，仅移架时提高不能解决；错误项2错在顶板隐患不能等大修处理；错误项3错在初撑力低于规定值不是正常波动，继续生产有冒顶风险。"},{"id":300,"type":"multi","stem":"某矿掘进工作面安全检查时，发现迎头临时支护的金属前探梁只用铁丝绑扎在棚梁上，且前探梁前端未插入迎头煤壁，检查人员应当认定为隐患并要求立即整改的情形有","options":["前探梁与棚梁采用铁丝绑扎固定","前探梁前端未插入迎头煤壁","前探梁上方背顶材料间距超过规定","前探梁使用前未进行每班外观检查"],"answer":[0,1],"explanation":"知识点：掘进迎头临时支护（前探梁）的固定与使用要求。前探梁必须用专用卡子或吊环固定在棚梁上，铁丝绑扎受力不可靠，属隐患，故第1项正确；前探梁前端必须插入迎头煤壁或预先施工的梁窝内，否则起不到超前支护作用，故第2项正确；背顶材料间距只要符合作业规程规定即为合规，间距超标才属隐患，题干未说明超标，故第3项不选；前探梁外观检查属班前检查内容，未检查属管理缺陷，但不属于前探梁固定与安设本身的立即整改隐患情形，故第4项不选。"}]}