{"name":"金属非金属矿山井下电气作业题库","level":"待补充","org":"应急管理部门","count":300,"questions":[{"id":1,"type":"single","stem":"井下变电所内一台低压馈电开关跳闸后，复位前电工首先应做的是","options":["查看开关显示屏故障代码并记录","直接合闸试送一次观察是否再跳","测量负载侧绝缘电阻是否合格","拉开上级隔离开关挂牌后开盖检查"],"answer":[0],"explanation":"知识点：井下低压开关跳闸后的处置程序。正确项对：先读取并记录故障代码，才能判断是过流、漏电还是欠压等故障类型，为后续检查提供方向。错误项错在：直接合闸试送可能使故障扩大或引发瓦斯环境下电弧危险；未判明故障类型就测绝缘，属于盲目操作；未确认故障原因就开盖检查，程序颠倒且不安全。"},{"id":2,"type":"single","stem":"井下电气设备检修时，验电后确认无电，下一步应做的工作是","options":["立即开始拆卸接线端子","对地放电并三相短接接地","用手背轻触导体确认无电","测量相间电阻判断是否断电"],"answer":[1],"explanation":"知识点：井下停电检修的安全技术措施顺序。正确项对：验电后必须对地放电并三相短接接地，防止电缆电容残余电荷或反送电伤人。错误项错在：验电后未放电接地就拆线，残余电荷可能电击；用手背触碰导体是危险陋习，不能代替验电接地；测相间电阻无法可靠确认无电且不能替代接地措施。"},{"id":3,"type":"single","stem":"井下采用局部通风机供风的掘进工作面，因检修需要停风时，对电气设备电源的正确处置是","options":["只停掘进工作面动力电源","停风前切断该工作面全部非本安电源","保留照明电源便于检修作业","由电工现场决定是否停电"],"answer":[1],"explanation":"知识点：停风区域电气设备的停电要求。正确项对：停风前必须切断该工作面全部非本质安全型电源，防止瓦斯积聚后电气火花引发事故。错误项错在：只停动力电源会遗漏照明、信号等非本安回路；保留照明电源同样留下点火源；是否停电不能由电工现场随意决定，应按规程执行。"},{"id":4,"type":"single","stem":"矿用隔爆型电气设备的隔爆外壳上，用于阻止火焰向外传播的核心结构是","options":["外壳的加厚钢板壁","隔爆接合面与隔爆间隙","外壳表面的防腐涂层","内部浇封的绝缘填充物"],"answer":[1],"explanation":"知识点：隔爆型设备的隔爆原理。正确项对：隔爆接合面和隔爆间隙能冷却火焰、阻止内部爆炸火焰引燃外部爆炸性气体。错误项错在：加厚壁只提高强度，不决定隔爆性能；防腐涂层只防腐蚀；浇封属于其他防爆型式（如浇封型）的措施，不是隔爆外壳的核心结构。"},{"id":5,"type":"single","stem":"井下电缆与管道同侧敷设时，电缆应布置在管道的","options":["上方并保持规定间距","下方并保持规定间距","同一水平紧贴管道","上方且可与管道交叉接触"],"answer":[0],"explanation":"知识点：井下电缆敷设位置要求。正确项对：电缆应敷设在管道上方并保持规定间距，防止管道漏水、漏气或检修时损伤电缆。错误项错在：布置在下方易受管道滴漏和检修影响；紧贴管道无间距，散热和检修都不允许；可与管道交叉接触违反间距和防护要求。"},{"id":6,"type":"single","stem":"井下检漏继电器动作使馈电开关跳闸后，在未查明原因前对该馈电开关的正确处理是","options":["退出检漏继电器后试送电","将漏电闭锁短接后试送电","不得强行送电并查找漏电点","改用手动方式合闸送电"],"answer":[2],"explanation":"知识点：漏电闭锁与检漏保护的动作后处置。正确项对：检漏继电器动作说明存在漏电或绝缘降低，必须查明并处理后才能恢复送电。错误项错在：退出检漏继电器等于失去漏电保护；短接漏电闭锁是严重违章，会掩盖故障；改手动合闸不能绕过漏电闭锁，且属强行送电。"},{"id":7,"type":"single","stem":"井下电气设备接地网上，任一点接地电阻值应满足的要求是","options":["不超过2欧姆","不超过4欧姆","不超过5欧姆","不超过10欧姆"],"answer":[0],"explanation":"知识点：井下接地网接地电阻限值。正确项对：金属非金属矿山井下接地网上任一保护接地点的接地电阻不得超过2欧姆。错误项错在：4欧姆、5欧姆、10欧姆均不符合井下接地电阻的严格要求，易造成漏电时接触电压过高。"},{"id":8,"type":"single","stem":"井下电工在带电的电气设备附近进行需要接触导体的作业时，正确的做法是","options":["戴普通棉纱手套操作","穿绝缘鞋并站在绝缘垫上","单手操作另一手接触接地体","缩短工具手柄直接作业"],"answer":[1],"explanation":"知识点：井下带电作业的个体防护。正确项对：穿绝缘鞋并站在绝缘垫上可限制通过人体的电流路径，是必要的绝缘防护。错误项错在：棉纱手套不绝缘；单手操作时另一手接触接地体会形成危险电流通路；缩短工具手柄减少绝缘距离，增加触电风险。"},{"id":9,"type":"single","stem":"井下某处照明灯具频繁烧坏，电工测量电压发现明显偏高，可能的直接原因是","options":["照明变压器分接头接错","灯具防爆型式选择偏低","电缆截面偏小压降过大","接地电阻偏大泄漏电流大"],"answer":[0],"explanation":"知识点：井下照明电压异常的原因分析。正确项对：照明变压器分接头接错会使二次电压偏高，导致灯具频繁烧坏。错误项错在：防爆型式偏低影响安全性能，不直接造成烧灯；电缆截面偏小造成的是压降过大、电压偏低；接地电阻偏大影响漏电保护，不使电压升高。"},{"id":10,"type":"single","stem":"井下电气设备安装完毕送电前，必须完成的绝缘检测项目是","options":["测量相间和对地绝缘电阻","测量接地网工频接地电阻","测量电缆直流电阻值","测量设备空载电流值"],"answer":[0],"explanation":"知识点：井下电气设备送电前的绝缘检测。正确项对：送电前必须测量相间和对地绝缘电阻，确认绝缘合格才能送电，防止短路或漏电。错误项错在：接地网工频接地电阻是接地系统测试项目，不是送电前绝缘检测；测电缆直流电阻用于判断导体连接质量；测空载电流不能判断绝缘状况。"},{"id":11,"type":"single","stem":"井下掘进工作面，电工发现一台运行中的局部通风机电机外壳温度明显升高且有焦糊味，正确处置是","options":["立即停机并切断电源检查","加强通风继续运行观察","降低电压运行减少发热","打开外壳散热后继续运行"],"answer":[0],"explanation":"知识点：井下电机异常发热的应急处置。正确项对：外壳过热且有焦糊味，说明可能绕组绝缘受损，应立即停机切断电源检查，防止烧毁或引发火灾。错误项错在：继续运行会扩大故障；降低电压不能消除绝缘故障且可能造成堵转发热；打开外壳既破坏防爆性能又可能触电。"},{"id":12,"type":"single","stem":"井下采区变电所低压馈电开关跳闸后，电工复位前应优先完成的检查项目是","options":["查看开关外观有无明显烧蚀痕迹","测量负荷侧绝缘电阻并确认无接地","询问上一班是否也发生过跳闸","合闸试送一次观察是否再跳"],"answer":[1],"explanation":"知识点：馈电开关跳闸后的复位前检查程序。正确项：跳闸多由绝缘损坏或接地引起，复位前必须测量绝缘、排除故障，否则可能扩大事故。错误项：外观检查只能发现明显损伤，不能代替绝缘测试；询问历史情况可供参考但不能替代本次检查；未查明原因试送电属于违章操作。"},{"id":13,"type":"single","stem":"井下低压电缆与高压电缆在同一巷道悬挂时，正确的敷设方式是","options":["高低压电缆同侧悬挂且间距不小于0.1m","高低压电缆分别挂在巷道两侧","高压电缆在上、低压电缆在下同钩悬挂","同侧悬挂但低压电缆用绝缘带绑在高压电缆上"],"answer":[1],"explanation":"知识点：井下电缆敷设的基本要求。正确项：高低压电缆应分侧悬挂，避免高压故障波及低压回路。错误项：同侧间距0.1m仍可能因高压击穿影响低压；同钩悬挂使低压电缆直接受高压影响；绑在高压电缆上属于严重错误敷设方式。"},{"id":14,"type":"single","stem":"井下电气设备隔爆外壳的隔爆结合面出现轻微锈蚀，正确的处理方法是","options":["用砂纸打磨除锈后涂防锈油","用棉纱擦净后直接安装使用","用刮刀刮除锈层再测量间隙","除锈后测量结合面间隙并涂薄层防锈油脂"],"answer":[3],"explanation":"知识点：隔爆结合面的维护要求。正确项：除锈后必须测量间隙是否符合要求，再涂薄层防锈油脂，保证隔爆性能。错误项：砂纸打磨会改变结合面粗糙度和间隙；仅擦净不处理锈蚀仍影响隔爆；刮刀刮除可能损伤结合面且未测间隙就安装。"},{"id":15,"type":"single","stem":"井下接地网中，主接地极与局部接地极之间的连接导线应采用","options":["截面不小于50mm²的铜线","截面不小于25mm²的铜线","截面不小于50mm²的镀锌钢绞线","截面不小于35mm²的铝线"],"answer":[0],"explanation":"知识点：井下接地网连接导线的截面要求。正确项：主接地极与局部接地极连接导线应采用截面不小于50mm²的铜线。错误项：25mm²铜线截面不足；镀锌钢绞线截面要求不同且易腐蚀；井下禁止使用铝线做接地连接线。"},{"id":16,"type":"single","stem":"井下电气设备检修时，验电环节的正确操作顺序是","options":["先验低压后验高压、先验近处后验远处","先验高压后验低压、先验远处后验近处","先验高压后验低压、先验近处后验远处","先验低压后验高压、先验远处后验近处"],"answer":[2],"explanation":"知识点：验电操作顺序。正确项：应先验高压后验低压、先验近处后验远处，逐步确认无电。错误项：先验低压后验高压顺序颠倒；先验远处后验近处不符合由近及远原则；低压优先且由远及近同样错误。"},{"id":17,"type":"single","stem":"井下移动式电气设备橡套电缆在巷道内落地敷设时，正确的做法是","options":["直接拖地敷设并定期冲洗","用挂钩悬挂且离地一定高度","落地敷设但每50m设一个接头","落地敷设并加盖木板保护"],"answer":[1],"explanation":"知识点：井下橡套电缆敷设要求。正确项：移动式设备橡套电缆应悬挂敷设，离地一定高度，防止被水浸泡和碾压。错误项：拖地敷设易受机械损伤和浸泡；落地敷设加接头增加故障点；加盖木板不能防止水浸和碾压。"},{"id":18,"type":"single","stem":"井下低压配电系统中，漏电保护装置动作后，电工正确的处置程序是","options":["立即重新合闸恢复供电","查明漏电原因并排除后再送电","将漏电保护退出运行后送电","短接漏电保护触点后送电"],"answer":[1],"explanation":"知识点：漏电保护动作后的处置。正确项：必须查明原因、排除故障后才能恢复送电。错误项：立即合闸可能造成人身触电；退出保护运行属于严重违章；短接触点使保护失效，严禁操作。"},{"id":19,"type":"single","stem":"井下电气设备隔爆外壳的紧固螺栓缺少弹簧垫圈时，正确的处理是","options":["用普通平垫圈代替弹簧垫圈","补装规格相同的弹簧垫圈","用两个平垫圈叠加代替","不装垫圈直接拧紧螺栓"],"answer":[1],"explanation":"知识点：隔爆外壳紧固件要求。正确项：必须补装规格相同的弹簧垫圈，保证紧固和防松。错误项：平垫圈无防松作用；两个平垫圈叠加仍不能防松；不装垫圈直接拧紧无法保证隔爆性能。"},{"id":20,"type":"single","stem":"井下采掘工作面电气设备需要搬迁时，正确的停电操作是","options":["由电工在配电点断开开关并挂牌","在设备旁直接断开负荷开关","由班组长通知后即可搬移","断开开关后即可开始搬迁"],"answer":[0],"explanation":"知识点：井下电气设备搬迁的停电程序。正确项：应由电工在配电点断开开关、挂牌并执行验电放电后搬迁。错误项：设备旁断开负荷开关不能切断电源侧；仅通知不能代替停电操作；断开开关后未验电放电不能搬迁。"},{"id":21,"type":"single","stem":"井下电气设备运行中闻到焦糊味且外壳温度明显升高，电工首先应做的是","options":["继续观察并记录温度变化","立即切断该设备电源并检查","打开外壳通风降温后继续运行","降低负荷继续运行至检修班"],"answer":[1],"explanation":"知识点：电气设备异常发热的应急处置。正确项：出现焦糊味和异常升温应立即切断电源检查，防止火灾或设备损坏扩大。错误项：继续观察可能延误处置；带电打开外壳违反规定；降负荷运行不能消除故障隐患。"},{"id":22,"type":"single","stem":"井下局部通风机供电线路中，实现风、电闭锁的正确做法是","options":["风机停转时自动切断掘进工作面动力电源","风机停转时自动切断风机自身电源","风机停转时自动发出声光报警","风机停转时自动切断变电所总电源"],"answer":[0],"explanation":"知识点：风电闭锁的功能。正确项：风机停转时自动切断掘进工作面动力电源，防止瓦斯积聚后继续作业。错误项：切断风机自身电源不能实现闭锁目的；仅报警不能切断动力电源；切断变电所总电源范围过大且影响其他区域。"},{"id":23,"type":"single","stem":"井下电气设备保护接地系统中，下列做法符合规定的有","options":["所有电气设备外壳均与接地网连接","接地线可串联连接多台设备外壳","接地极可用铝板制作以减轻重量","接地电阻每年至少测定一次","移动设备可用橡套电缆接地芯线接地"],"answer":[0,3],"explanation":"知识点：井下保护接地系统的基本要求。正确项：所有电气设备外壳均须与接地网连接；接地电阻每年至少测定一次。错误项：接地线串联连接会使一处断开导致后续设备失去接地；铝板易腐蚀且井下不宜用铝做接地极；移动设备接地芯线不能替代独立接地连接。"},{"id":24,"type":"single","stem":"井下中央变电所向采区变电所供电的电缆在巷道内吊挂时，吊挂点间距应保证电缆不承受过大拉力，通常水平段吊挂点间距不应超过多少米","options":["1米","3米","6米","10米"],"answer":[1],"explanation":"知识点：井下电缆敷设吊挂间距要求。水平巷道电缆吊挂点间距一般不超过3米，可防止电缆因自重下坠受力。错项分析：1米间距过密，增加吊挂件数量但非标准要求；6米间距过大，电缆会明显下垂并承受过大拉力；10米间距更大，无法保证固定可靠。"},{"id":25,"type":"single","stem":"矿用隔爆型电气设备隔爆外壳上的隔爆接合面出现轻微锈蚀，正确的处理方式是","options":["用砂纸打磨至露出金属光泽","涂少量防锈油后继续使用","用棉纱擦净锈迹即可","用刮刀铲除锈斑后补漆"],"answer":[1],"explanation":"知识点：隔爆接合面维护要求。隔爆接合面轻微锈蚀应涂薄层防锈油防止继续锈蚀，保持隔爆性能。错项分析：砂纸打磨会改变接合面间隙和粗糙度，破坏隔爆性能；棉纱擦净不能阻止锈蚀发展且未做防护；刮刀铲除会损伤接合面平面度。"},{"id":26,"type":"single","stem":"井下低压馈电线上安装的漏电保护装置，其作用是在电网对地绝缘电阻下降到危险值时","options":["自动切断该馈电线路电源","仅发出声光报警信号","自动降低线路运行电压","自动投入备用绝缘监测装置"],"answer":[0],"explanation":"知识点：井下低压漏电保护功能。漏电保护装置在绝缘电阻降至危险值时自动切断电源，防止人身触电和漏电火灾。错项分析：仅报警不切断不能消除危险；降低电压不能消除漏电隐患；投入备用监测装置不解决当前漏电问题。"},{"id":27,"type":"single","stem":"井下电气设备接地网上，任一点接地电阻值不得大于多少欧姆","options":["1欧姆","2欧姆","4欧姆","10欧姆"],"answer":[1],"explanation":"知识点：井下接地网接地电阻限值。金属非金属矿山井下接地网上任一保护接地点的接地电阻不得超过2欧姆。错项分析：1欧姆要求过严，一般仅特殊场所要求；4欧姆是地面电气设备常见要求；10欧姆过大，不能保证漏电时保护可靠动作。"},{"id":28,"type":"single","stem":"有一台井下移动变压器需从甲巷道移到乙巷道，搬迁前对电缆的处理，正确做法是","options":["带电搬迁并设专人看护电缆","停电后验电放电再拆线搬迁","停电后直接拆线不必验电","只停高压侧低压侧带电搬迁"],"answer":[1],"explanation":"知识点：井下电气设备搬迁安全操作。搬迁前必须停电、验电、放电，确认无电后再拆线搬迁，防止残余电荷和反送电伤人。错项分析：带电搬迁违反停电作业基本要求；停电后不验电放电可能触电；只停高压侧低压侧仍带电，拆线时危险。"},{"id":29,"type":"single","stem":"井下电气设备外壳接地与电缆金属护套接地相比，下列认识正确的是","options":["外壳接地可代替电缆护套接地","电缆护套接地可代替外壳接地","两者都需可靠接地且连成接地网","电缆护套在井下可不接地"],"answer":[2],"explanation":"知识点：井下接地系统构成。电气设备外壳和电缆金属护套都必须可靠接地并连成统一接地网，不能互相代替。错项分析：外壳接地不能代替护套接地，护套感应电压需单独泄放；护套接地也不能代替外壳接地；护套在井下必须接地，否则绝缘损坏时护套带电。"},{"id":30,"type":"single","stem":"井下检漏保护装置动作后，值班电工在未查明原因前，正确的处置是","options":["试送电一次观察是否再跳","将检漏保护短接后送电","提高整定值后送电","查明并消除漏电原因后再送电"],"answer":[3],"explanation":"知识点：漏电保护动作后处置原则。必须查明并消除漏电原因后才能恢复送电，严禁强行送电。错项分析：试送电可能扩大事故；短接检漏保护使线路失去保护；提高整定值掩盖真实漏电，均属严重违章。"},{"id":31,"type":"single","stem":"井下敷设电缆时，电缆与压风管、供水管在巷道同一侧悬挂，电缆应位于管子上方并保持一定距离，这一要求的主要目的是","options":["防止管路漏水淋湿电缆","便于电缆检修时抽拉","防止管路维修时损伤电缆","避免管路振动传到电缆"],"answer":[2],"explanation":"知识点：井下电缆与管路敷设位置要求。电缆位于管子上方且保持距离，主要防止管路检修、拆卸时碰伤电缆。错项分析：防止淋湿不是主要目的；便于抽拉非规范要求；避免振动传递不是该距离规定的主因。"},{"id":32,"type":"single","stem":"井下某处照明线路绝缘电阻测量值偏低，电工用兆欧表测量时，正确的做法是","options":["在停电并验电放电后测量","在带电情况下直接测量","只测量相间绝缘不测对地","用万用表电阻档代替兆欧表"],"answer":[0],"explanation":"知识点：绝缘电阻测量安全操作。测量前必须停电、验电、放电，确保安全和测量准确。错项分析：带电测量会损坏仪表并危及人身；只测相间不测对地不全面；万用表电阻档电压低，不能反映绝缘真实状况。"},{"id":33,"type":"single","stem":"井下变电所一台开关突然跳闸，复电后再次跳闸，电工下一步最合理的处置是","options":["再次合闸观察跳闸时间","检查该回路有无短路或漏电","更换更大容量开关后送电","将该回路负荷转移到其他开关"],"answer":[1],"explanation":"知识点：开关反复跳闸的故障判断。连续跳闸说明回路存在短路、漏电或保护误动，应检查回路故障点。错项分析：反复合闸会扩大事故；换大开关失去保护配合；转移负荷不能消除故障且影响其他回路。"},{"id":34,"type":"single","stem":"井下电气检修中，验电确认无电后，下一步应立即进行的是","options":["挂接地线并三相短路","装设临时遮栏","悬挂停电标示牌","测量绝缘电阻"],"answer":[0],"explanation":"知识点：井下停电检修安全程序。正确项对：验电后立即挂接地线并三相短路，是防止反送电和残余电荷伤人的关键步骤。错误项：装设遮栏属于隔离措施，应在接地后进行；悬挂标示牌是警示措施，不能替代接地；测绝缘电阻属于检修测试，必须在接地拆除后、送电前进行。"},{"id":35,"type":"single","stem":"矿用防爆电气设备隔爆外壳的隔爆面出现轻微锈蚀时，正确的处理方式是","options":["用砂纸打磨至露出金属光泽","涂少量防锈油后继续使用","用棉纱擦净锈粉后装配","用刮刀刮平锈斑再涂漆"],"answer":[1],"explanation":"知识点：隔爆面维护要求。正确项对：轻微锈蚀可用化学或机械方法清除后涂防锈油，保持隔爆面间隙和粗糙度符合要求。错误项：砂纸打磨会改变隔爆面间隙和粗糙度；仅擦净锈粉不能阻止继续锈蚀；刮平后涂漆会改变隔爆面尺寸且漆层影响隔爆性能。"},{"id":36,"type":"single","stem":"井下低压电网采用中性点不接地系统时，检漏保护装置的主要作用是","options":["切除短路故障电流","监视对地绝缘并动作","限制单相接地电流","补偿电容性泄漏电流"],"answer":[1],"explanation":"知识点：井下检漏保护功能。正确项对：检漏保护装置监视电网对地绝缘电阻，绝缘降低到危险值时报警或跳闸。错误项：切除短路电流由过流保护完成；限制接地电流是消弧线圈等功能；补偿电容电流不是检漏装置的任务。"},{"id":37,"type":"single","stem":"井下电气设备中，用于防止人员触电的漏电闭锁功能，其动作时机是","options":["设备启动后检测到漏电跳闸","合闸前检测漏电并闭锁启动","运行中漏电持续报警","漏电后延时自动重合闸"],"answer":[1],"explanation":"知识点：漏电闭锁与漏电保护的区别。正确项对：漏电闭锁在合闸前检测电网绝缘，不合格时闭锁启动，避免带故障合闸。错误项：启动后跳闸属于漏电保护动作；运行中报警不闭锁启动；漏电后重合闸会扩大事故，是错误做法。"},{"id":38,"type":"single","stem":"井下电缆悬挂时，电缆与风管、水管的间距要求是","options":["电缆应挂在管子上方并保持间距","电缆应挂在管子下方并保持间距","电缆与管子同侧紧贴悬挂","电缆与管子交叉悬挂即可"],"answer":[0],"explanation":"知识点：井下电缆敷设要求。正确项对：电缆应敷设在管子等管道上方并保持规定间距，防止管道漏水、漏风影响电缆。错误项：挂在下方易受管道滴漏影响；紧贴悬挂和交叉悬挂均不符合间距要求。"},{"id":39,"type":"single","stem":"井下电气设备接地网上，接地极的安装方式正确的是","options":["多根接地极并联后接设备外壳","单根接地极串联接多台设备","接地极必须垂直打入含水层","接地干线可兼作接地极"],"answer":[0],"explanation":"知识点：井下接地网安装。正确项对：多根接地极并联可降低接地电阻，设备外壳分别接入接地网。错误项：串联会使接地电阻叠加且一处断开影响多台设备；接地极不一定必须打入含水层；接地干线不能兼作接地极。"},{"id":40,"type":"single","stem":"井下移动变电站低压侧漏电保护动作后，值班电工首先应做的是","options":["直接复位试送电","查找漏电原因并处理","断开高压侧开关","测量变压器绝缘"],"answer":[1],"explanation":"知识点：漏电保护动作后处置。正确项对：先查明漏电原因并处理，不能盲目复位送电。错误项：直接复位可能再次跳闸或扩大事故；断开高压侧不是首要步骤；测变压器绝缘不是首先应做的针对性检查。"},{"id":41,"type":"single","stem":"井下某掘进工作面照明综保装置频繁跳闸，检查发现灯具接线盒内有水珠，正确处理是","options":["更换更大容量综保装置","烘干接线盒并密封处理","调高漏电动作整定值","将照明线路改接动力线路"],"answer":[1],"explanation":"知识点：井下照明综保跳闸异常判断。正确项对：接线盒进水导致绝缘下降，应烘干并做密封处理。错误项：增大容量不能解决漏电；调高整定值会失去保护作用；改接动力线路违反规定且扩大故障范围。"},{"id":42,"type":"single","stem":"矿用一般型电气设备与矿用防爆型电气设备的主要区别在于","options":["是否允许在井下任何地点使用","外壳防护等级不同","是否具有隔爆或本质安全性能","额定电压等级不同"],"answer":[2],"explanation":"知识点：矿用电气设备类型辨析。正确项对：防爆型具有隔爆或本质安全等防爆性能，一般型不具备。错误项：使用地点限制不是主要区别；外壳防护等级只是部分差异；额定电压等级不是分类依据。"},{"id":43,"type":"single","stem":"井下变电硐室内的低压馈电开关，其金属外壳必须与接地网连接的部位是","options":["开关底座的安装螺栓处","开关操作手柄的转动轴处","开关门板与铰链的接触面处","开关内部母排的支撑绝缘子处"],"answer":[0],"explanation":"知识点：井下电气设备外壳接地要求。正确项：外壳接地应通过底座安装螺栓与接地网可靠连接，这是标准接地路径。错误项：操作手柄转动轴不是接地连接点；门板铰链接触面不能作为保护接地通路；母排支撑绝缘子仅起绝缘支撑作用，不承担接地功能。"},{"id":44,"type":"single","stem":"井下低压橡套电缆在巷道帮壁上悬挂时，电缆与风水管之间的最小允许间距是","options":["0.1 m","0.2 m","0.3 m","0.5 m"],"answer":[2],"explanation":"知识点：井下电缆敷设安全间距。正确项：电缆与风水管同侧悬挂时须保持0.3 m以上间距，防止管路漏气漏水影响电缆绝缘。错误项：0.1 m和0.2 m间距过小，管路故障时易损伤电缆；0.5 m虽是更大间距但非规程规定的最小值，容易与电缆与运输机间距要求混淆。"},{"id":45,"type":"single","stem":"井下电气设备隔爆外壳的隔爆面有轻度锈蚀，检修时正确的处理方式是","options":["用砂纸打磨至露出金属光泽后涂防锈油","用棉纱擦去浮锈后直接装配使用","用刮刀刮净锈斑并测量间隙合格后涂薄油","用酸洗除锈后晾干再装配"],"answer":[2],"explanation":"知识点：隔爆面检修工艺。正确项：轻度锈蚀可用刮刀刮净，但必须测量隔爆间隙是否仍在允许范围内，合格后涂薄防锈油。错误项：砂纸打磨会改变隔爆面粗糙度和间隙；棉纱擦去浮锈未彻底除锈且未测间隙；酸洗会腐蚀隔爆面并改变配合尺寸。"},{"id":46,"type":"single","stem":"井下移动变电站低压侧漏电保护装置动作后，在未查明原因前反复试送电，可能造成的直接后果是","options":["漏电保护装置自动闭锁解除","故障点短路电流引发瓦斯煤尘爆炸","漏电电流持续灼伤电缆绝缘形成短路","变压器低压绕组匝间绝缘击穿"],"answer":[2],"explanation":"知识点：漏电保护动作后的处置原则。正确项：反复试送电会使漏电电流持续流过故障点，逐步灼伤绝缘最终发展为短路。错误项：漏电保护不会因试送电解除闭锁；反复试送电本身不直接产生爆炸所需能量条件；变压器绕组击穿是短路后的间接后果而非直接后果。"},{"id":47,"type":"single","stem":"井下电气作业人员在检修高压开关柜时，验电确认无电后的下一步操作是","options":["立即装设接地线并悬挂标示牌","先对地放电再装设接地线","直接用手触摸导电部位确认无电","合上接地开关后开始检修"],"answer":[1],"explanation":"知识点：高压设备检修安全操作程序。正确项：验电后必须先对地放电，消除剩余电荷，再装设接地线。错误项：跳过放电直接装接地线可能遭剩余电荷电击；用手触摸确认无电是严重违规；合接地开关前仍需先放电，顺序不能颠倒。"},{"id":48,"type":"single","stem":"井下照明变压器二次侧采用不接地系统时，其二次侧应装设的漏电保护装置是","options":["零序电流型漏电保护","漏电闭锁装置","绝缘监视装置","接地故障电流保护"],"answer":[2],"explanation":"知识点：不接地系统漏电保护方式。正确项：不接地系统单相接地时故障电流很小，应采用绝缘监视装置监测系统对地绝缘状况。错误项：零序电流型适用于接地系统；漏电闭锁用于设备送电前检测；接地故障电流保护针对的是接地系统的大电流故障。"},{"id":49,"type":"single","stem":"井下电气设备防爆标志中，表示设备为矿用隔爆型的是","options":["Ex d I","Ex e II","Ex i I","Ex p I"],"answer":[0],"explanation":"知识点：防爆标志含义。正确项：Ex d I中d表示隔爆型，I表示煤矿用电气设备。错误项：Ex e为增安型；Ex i为本安型；Ex p为正压型，均非隔爆型。"},{"id":50,"type":"single","stem":"井下低压电网中，用于防止人身触电的漏电保护装置动作电流值应不大于","options":["30 mA","50 mA","100 mA","200 mA"],"answer":[0],"explanation":"知识点：漏电保护动作电流整定。正确项：防止人身触电的漏电保护动作电流应不大于30 mA，这是人身安全电流限值。错误项：50 mA、100 mA、200 mA均超过人身安全电流限值，不能有效防止触电伤亡。"},{"id":51,"type":"single","stem":"井下电缆连接时，采用冷压接法连接铜芯电缆，压接后的接头绝缘处理应","options":["缠绕绝缘胶带后即可投入使用","压接后涂导电膏再缠绝缘带","压接后先测接触电阻再恢复绝缘","压接后直接套热缩管加热收缩"],"answer":[2],"explanation":"知识点：电缆接头连接工艺。正确项：压接后应先测量接触电阻，确认连接质量合格后再恢复绝缘，否则接头过热隐患无法发现。错误项：直接缠绝缘带未验证连接质量；涂导电膏不能替代接触电阻检测；直接套热缩管同样跳过了质量验证环节。"},{"id":52,"type":"single","stem":"井下电气设备运行中，隔爆外壳内产生电弧后，隔爆外壳的作用是","options":["阻止外部空气进入壳内助燃","冷却从壳内喷出的火焰使其不能点燃外部气体","吸收壳内爆炸产生的全部能量","自动切断电源防止事故扩大"],"answer":[1],"explanation":"知识点：隔爆外壳原理。正确项：隔爆外壳通过隔爆面的间隙冷却喷出的火焰，使其温度降到点燃外部爆炸性气体所需温度以下。错误项：隔爆外壳不阻止空气进入；不能吸收全部爆炸能量；自动切断电源是保护装置功能而非外壳功能。"},{"id":53,"type":"single","stem":"井下电气检修中，验电器使用前应在带电体上试验，其主要目的是","options":["校准验电器的报警声压级","确认验电器本身完好可用","测量带电体的实际电压值","检查验电器的绝缘杆耐压水平"],"answer":[1],"explanation":"知识点：验电器使用前检查。正确项：验电器使用前必须在带电体上试验，确认其本身能正常报警，防止因验电器损坏导致误判无电。错误项：校准声压级不是现场能做的；验电器不用于测量电压值；绝缘杆耐压试验是定期预防性试验项目，非使用前检查内容。"},{"id":54,"type":"multi","stem":"井下电气作业中，下列属于防止电气火灾扩大措施的有","options":["在电缆接头处装设温度监测装置","变电硐室设置砂箱和灭火器材","电气设备外壳涂刷防火涂料","在电缆沟内充填砂子隔离","定期清理设备周围可燃物"],"answer":[1,3,4],"explanation":"知识点：井下电气火灾预防与扩大措施。正确项：变电硐室设置砂箱灭火器材可及时扑灭初起火灾；电缆沟充填砂子可隔离火源阻止蔓延；清理可燃物可减少火灾荷载。错误项：温度监测属于火灾预警措施而非扩大措施；外壳涂防火涂料对内部电气火灾扩大无实质阻止作用。"},{"id":55,"type":"single","stem":"井下变电所内检漏继电器动作后，在恢复送电前应首先完成的确认工作是","options":["查看是哪一相绝缘降低并排除故障","将漏电闭锁旋钮暂时打到解除位","测量电网对地绝缘电阻是否合格","通知采区电工到现场后再送电"],"answer":[2],"explanation":"知识点：漏电闭锁与恢复送电条件。检漏继电器动作后必须先确认电网对地绝缘电阻恢复到规定值以上，才能解除闭锁送电；查看哪一相不是首要动作，解除闭锁是违规，仅通知人员不构成送电条件。"},{"id":56,"type":"single","stem":"井下电气设备检修需要停电时，验电环节的正确操作是","options":["用低压验电笔在开关出线侧逐相验电","用相应电压等级验电器在可能来电各侧逐相验电","合上隔离开关用试送电方法判断有无电","用万用表在母线上测量线电压判断"],"answer":[1],"explanation":"知识点：停电—验电—放电—装设接地线程序。验电应使用电压等级合适且合格的验电器，在可能来电各侧逐相进行；低压验电笔不能用于高压或未知电压，试送电和万用表测线电压都不能可靠确认无电。"},{"id":57,"type":"single","stem":"井下低压馈电开关中，过流保护整定值偏小最可能造成的运行后果是","options":["短路时开关拒动越级跳闸","正常启动时开关误动作停电","漏电闭锁功能自动失效","三相电流不平衡报警频繁"],"answer":[1],"explanation":"知识点：过流保护整定原则。整定值小于电动机正常启动电流时，启动过程中开关会误动作；整定过大才可能拒动，漏电闭锁由绝缘检测回路决定，与过流整定无关，电流不平衡报警属另一保护功能。"},{"id":58,"type":"single","stem":"井下电气设备隔爆外壳的隔爆性能主要依靠","options":["外壳壁厚足以承受内部爆炸压力","外壳接合面的间隙和长度参数","外壳内外表面涂有耐弧绝缘漆","外壳上装有泄压阀释放压力"],"answer":[1],"explanation":"知识点：隔爆原理。隔爆外壳靠接合面的间隙、长度和表面粗糙度共同作用，使内部爆炸火焰在逸出时被冷却熄灭；壁厚、涂漆、泄压阀都不是隔爆性能的核心依据。"},{"id":59,"type":"single","stem":"井下敷设电缆时，铠装电缆与橡套电缆在悬挂方式上的正确区别是","options":["铠装电缆用卡子固定，橡套电缆用吊钩悬挂","铠装电缆直接落地，橡套电缆必须悬挂","铠装电缆用吊钩悬挂，橡套电缆用卡子固定","两者都必须用卡子固定在巷道壁上"],"answer":[0],"explanation":"知识点：井下电缆悬挂要求。铠装电缆一般用卡子或吊挂件固定，橡套电缆因柔软多采用吊钩悬挂并留适当垂度；落地敷设不符合井下安全要求，两者固定方式不能互换。"},{"id":60,"type":"single","stem":"井下移动变电站高压侧电缆连接器在运行中发热，最可能的原因是","options":["连接器内绝缘油位偏高","连接器插接面接触电阻过大","连接器外壳接地电阻偏小","连接器所处巷道风速偏大"],"answer":[1],"explanation":"知识点：电缆连接器发热原因。插接面氧化、压紧不足或接触面有杂质会使接触电阻增大而发热；油位偏高、接地电阻偏小、风速偏大都不是连接器发热的直接原因。"},{"id":61,"type":"single","stem":"井下电气作业中，接地网上任意一点测得的接地电阻值应满足的要求是","options":["不超过该点局部接地极的设计值","不超过接地网总接地电阻的规定值","不超过被保护设备外壳的接触电阻","不超过电缆铠装层的直流电阻"],"answer":[1],"explanation":"知识点：井下接地网电阻要求。接地网上任意一点的接地电阻都应符合总接地电阻的规定限值；局部接地极设计值、外壳接触电阻、铠装直流电阻都不是判定接地网合格的指标。"},{"id":62,"type":"single","stem":"井下检漏保护装置做就地试验时，发现按下试验按钮后开关不跳闸，正确的下一步处置是","options":["改用远方试验按钮再试一次","将该开关退出运行并检查试验回路","调整漏电动作值后重新试验","继续运行待定期检修时处理"],"answer":[1],"explanation":"知识点：检漏保护试验异常处置。试验按钮按下不跳闸说明试验回路或保护装置本身存在缺陷，应退出运行检查；换按钮、调动作值、拖到检修都不符合保护装置必须可靠动作的要求。"},{"id":63,"type":"single","stem":"井下采区变电所内两台变压器并联运行，接线组别不同会造成的直接后果是","options":["二次侧电压相位不同产生环流","两台变压器负荷按容量比例分配","一次侧电流自动趋于平衡","二次侧输出电压自动升高"],"answer":[0],"explanation":"知识点：变压器并联运行条件。接线组别不同会使二次侧电压相位不一致，在绕组间产生环流；负荷分配、电流平衡、电压升高都不是组别不同带来的正常结果。"},{"id":64,"type":"single","stem":"井下电气设备搬迁后重新安装，送电前对电缆绝缘电阻的检查应","options":["只测相间绝缘，对地可不测","分别测量相间和对地绝缘电阻","只测对地绝缘，相间可不测","用万用表电阻档代替绝缘电阻表"],"answer":[1],"explanation":"知识点：电缆送电前绝缘检查。相间和对地绝缘都必须测量，任一不合格都不得送电；只测一项会漏判缺陷，万用表电阻档电压低不能替代绝缘电阻表。"},{"id":65,"type":"multi","stem":"井下电气设备检修中，属于必须执行的安全措施有","options":["停电后验电并装设接地线","悬挂有人工作禁止合闸标示牌","检修完毕由原停电人下令送电","送电前清点工具并拆除接地线","带电检测时设专人监护即可"],"answer":[0,1,3],"explanation":"知识点：检修安全措施。停电验电装接地线、悬挂标示牌、送电前清点工具并拆除接地线都是必须执行的项目；送电应由原停电人下令但需确认全部条件满足，带电检测设专人监护不能代替停电措施。"},{"id":66,"type":"single","stem":"井下变电所低压馈电开关跳闸后，重新送电前应先做的检查是","options":["用验电笔确认负荷侧无电后直接合闸","查看漏电闭锁指示并查明跳闸原因","将开关手把打到试验位置试合一次","测量电源侧电压是否达到额定值"],"answer":[1],"explanation":"知识点：低压馈电开关跳闸后的处置程序。跳闸说明线路可能存在漏电、过载或短路，必须先查明原因并确认漏电闭锁状态正常后才能送电。A项未查明原因直接合闸属盲目送电；C项试验位置只能检验开关机构，不能代替故障排查；D项电源侧电压与跳闸原因无直接关系。"},{"id":67,"type":"single","stem":"井下电气设备金属外壳与接地网连接时，正确的连接方式是","options":["用设备底脚螺栓兼作接地连接点","采用专门接地螺栓且接触面除锈镀锡","将接地线缠绕在电缆铠装上固定","把多台设备外壳串联后接一根接地线"],"answer":[1],"explanation":"知识点：井下电气设备保护接地连接要求。正确做法是用专门接地螺栓连接并保证接触良好、防锈。A项底脚螺栓承力且易松动，不能兼作接地；C项缠绕连接接触电阻大且不可靠；D项串联接地会使一台设备断开导致后续设备失去保护。"},{"id":68,"type":"single","stem":"井下敷设电缆时，电缆与压风管、供水管在巷道同一侧悬挂的允许位置关系是","options":["电缆挂在管子上方约0.3米处","电缆挂在管子下方约0.3米处","电缆与管子并排紧贴固定","电缆挂在管子下方约0.1米处"],"answer":[0],"explanation":"知识点：井下电缆与管路的敷设间距要求。电缆应敷设在管子上方并保持约0.3米距离，防止管路漏水或检修时损伤电缆。B项、D项电缆在下方易受潮和检修破坏；C项紧贴固定不符合间距要求。"},{"id":69,"type":"single","stem":"井下检漏保护装置动作后，若未找到故障点就按下复位按钮强行送电，可能造成的直接后果是","options":["漏电保护装置永久失效","故障线路带漏电继续运行引发触电","馈电开关机构卡死无法再合闸","接地网电位升高烧毁变压器"],"answer":[1],"explanation":"知识点：漏电闭锁与复位操作的安全逻辑。未排除故障就复位送电，会使漏电线路继续带电，直接威胁人身安全。A项复位不会使装置永久失效；C项复位与开关机构卡死无必然联系；D项接地网电位升高不是该操作的直接后果。"},{"id":70,"type":"single","stem":"井下电气检修中需要停高压开关时，正确的操作顺序是","options":["先拉隔离开关再拉断路器","先拉断路器再拉隔离开关","只拉断路器并悬挂标示牌","先合接地开关再拉断路器"],"answer":[1],"explanation":"知识点：高压开关停电操作顺序。必须先由断路器切断负荷电流，再拉隔离开关隔离电源，防止隔离开关带负荷拉闸产生电弧。A项顺序颠倒，属带负荷拉隔离开关；C项缺少隔离开关明显断开点；D项先合接地开关属带电合接地，极其危险。"},{"id":71,"type":"single","stem":"井下移动式电气设备橡套电缆的接地芯线，其正确使用方式是","options":["可兼作控制回路导线使用","只能作接地连接不得他用","可临时作为信号线使用","可与动力芯线并联使用"],"answer":[1],"explanation":"知识点：橡套电缆接地芯线的专用性。接地芯线专用于保护接地，一旦兼作其他回路，接地保护将失效。A项、C项、D项均将接地芯线挪作他用，会使设备外壳失去可靠接地。"},{"id":72,"type":"single","stem":"井下电气设备隔爆外壳的隔爆结合面有轻微锈蚀时，正确的处理方式是","options":["用砂纸打磨后涂少量黄油","用棉纱擦净后涂防锈油脂","用刮刀刮平后直接装配","不做处理继续使用"],"answer":[1],"explanation":"知识点：隔爆结合面的维护要求。隔爆面应保持清洁并涂防锈油脂，不得损伤其间隙。A项砂纸打磨会改变结合面间隙；C项刮刀刮平同样破坏隔爆参数；D项锈蚀不处理会增大间隙，失去隔爆性能。"},{"id":73,"type":"single","stem":"井下照明变压器二次侧采用安全电压供电时，其二次绕组与一次绕组之间的正确关系是","options":["共用一组绕组抽头取得","相互绝缘并各自独立","二次绕组直接接地","一次绕组接二次绕组中性点"],"answer":[1],"explanation":"知识点：井下安全电压照明变压器的结构要求。一次侧与二次侧绕组必须相互绝缘、彼此独立，防止高压串入低压侧。A项抽头方式不能保证隔离；C项二次绕组接地不符合安全电压供电要求；D项连接方式会造成高低压混接。"},{"id":74,"type":"single","stem":"井下某处电缆接头运行中发热严重，电工检查发现压接处接触电阻偏大，正确的处置是","options":["在该接头外再并接一根短电缆分流","重新压接接头并测量接触电阻合格","涂导电膏后继续运行观察","降低该线路负荷继续使用"],"answer":[1],"explanation":"知识点：电缆接头过热的原因与处理。接触电阻偏大应重新压接并检测合格。A项并接短电缆不能解决原接头缺陷；C项涂导电膏不能降低已劣化的压接电阻；D项降负荷只是临时缓解，未消除隐患。"},{"id":75,"type":"single","stem":"井下电工在未经通风检测的盲巷内处理照明线路故障，最先应做的工作是","options":["断开照明开关后进入检查","检测该处空气成分合格后再作业","佩戴防尘口罩直接进入","通知同伴在巷口等待后进入"],"answer":[1],"explanation":"知识点：井下作业前的气体检测要求。盲巷可能积聚有毒有害气体或缺氧，必须先检测空气成分合格。A项断电不能替代气体检测；C项防尘口罩不能防护有毒气体；D项同伴在巷口等待无法阻止中毒窒息风险。"},{"id":76,"type":"single","stem":"井下电气设备的保护接地网中，主接地极的正确设置方式是","options":["在水仓或积水坑中设置不少于两块","在巷道底板打一根钢管即可","与井下供水管路连接代替","在变电所地面埋设一块钢板"],"answer":[0],"explanation":"知识点：井下主接地极的设置要求。主接地极应设在水仓或积水坑中且不少于两块，以保证接地可靠。B项单根钢管不能满足主接地极要求；C项供水管路不能代替主接地极；D项地面埋设钢板不符合主接地极设置位置。"},{"id":77,"type":"single","stem":"井下电气设备隔爆外壳的隔爆接合面出现轻微锈蚀，检修时应","options":["用砂纸打磨除锈后涂防锈油","用刮刀刮净锈层后直接装配","涂少量油漆覆盖锈斑","用棉纱擦净后涂凡士林"],"answer":[0],"explanation":"知识点：隔爆接合面维护。轻微锈蚀可用砂纸打磨除锈并涂防锈油，保持接合面间隙和粗糙度。刮刀会破坏接合面精度；油漆改变间隙且易燃；凡士林不能除锈且高温流失。"},{"id":78,"type":"single","stem":"井下低压配电系统中，检漏继电器动作后恢复送电前必须先做的工作是","options":["查明并排除漏电故障点","将检漏继电器退出运行","把漏电闭锁值调大","对电网进行人工放电"],"answer":[0],"explanation":"知识点：漏电保护动作后处置程序。必须先查明并排除漏电故障点，否则送电可能引发事故。退出检漏继电器、调大闭锁值都是甩保护的错误做法；人工放电是停电检修后的步骤，不是送电前首要工作。"},{"id":79,"type":"single","stem":"井下电工在检修高压开关柜时，验电确认无电后应随即","options":["对地放电并挂接地线","直接开始拆卸母排螺栓","合上接地开关后离场","测量绝缘电阻并记录"],"answer":[0],"explanation":"知识点：高压设备停电检修安全措施。验电后必须对地放电并装设接地线，防止残余电荷和反送电伤人。直接拆卸母排违反验电后放电接地顺序；合接地开关后离场无人监护；测绝缘应在接地线拆除后进行。"},{"id":80,"type":"single","stem":"井下使用的防爆电磁起动器中，隔离开关与主接触器之间设置电气联锁的目的是","options":["防止带负荷分断隔离开关","防止接触器频繁动作","防止电机反转运行","防止控制回路失压"],"answer":[0],"explanation":"知识点：防爆起动器联锁功能。隔离开关与接触器联锁是防止带负荷分断隔离开关产生电弧。防止频繁动作靠操作规范；防止反转靠相序；防止失压靠欠压保护，均非该联锁目的。"},{"id":81,"type":"single","stem":"井下照明变压器二次侧采用中性点不接地系统时，照明灯具金属外壳应采取的接地方式是","options":["经照明电缆芯线接至接地网","就近接在巷道金属支架上","单独打一根接地极局部接地","与轨道焊接后接地"],"answer":[0],"explanation":"知识点：井下照明保护接地。中性点不接地系统灯具外壳应经电缆芯线接至接地网形成保护接地。接巷道支架、轨道不能保证接地电阻且不可靠；单独打接地极不符合井下接地网统一要求。"},{"id":82,"type":"single","stem":"井下某采区变电所值班电工发现高压开关柜内有异常放电声，柜面无保护动作信号，正确的下一步处置是","options":["立即汇报并按程序停电检查","打开柜门用手电查看放电点","按下试验按钮观察保护动作","记录声音间隔后继续监视运行"],"answer":[0],"explanation":"知识点：异常放电处置。有放电声说明绝缘可能已损坏，应立即汇报并按程序停电检查。带电开门查看极易触电；按试验按钮可能误动；继续运行可能发展为短路事故。"},{"id":83,"type":"single","stem":"井下巷道掘进面移动式变压器在移设后送电前，除检查接线和绝缘外还应重点确认","options":["接地装置已按要求重新装设","变压器油位高于正常油面","低压侧电压高于额定值","高压电缆长度满足敷设要求"],"answer":[0],"explanation":"知识点：移动变压器移设后送电条件。移设后接地装置必须重新装设并合格，这是送电前提。油位、电压、电缆长度都不是移设后送电前必须重新确认的关键项。"},{"id":84,"type":"single","stem":"井下电气设备检修中需要更换隔爆外壳上的紧固螺栓时，正确的做法是","options":["使用相同规格和强度等级的螺栓","用长度略长的普通螺栓代替","用不锈钢螺栓替换原碳钢螺栓","缺少弹簧垫圈时用平垫圈代替"],"answer":[0],"explanation":"知识点：隔爆外壳紧固件要求。必须使用相同规格和强度等级的螺栓，保证隔爆性能。加长普通螺栓、随意换材质、以平垫代弹簧垫都会影响紧固和隔爆间隙。"},{"id":85,"type":"single","stem":"井下低压馈电开关的过流保护整定值，应根据被保护线路的什么参数确定","options":["最大负荷电流和短路电流","额定电压和功率因数","电缆长度和敷设方式","变压器容量和空载电流"],"answer":[0],"explanation":"知识点：过流保护整定依据。整定值按最大负荷电流躲过正常尖峰，并按短路电流校验灵敏度。电压、功率因数、敷设方式、空载电流都不是过流整定的直接依据。"},{"id":86,"type":"single","stem":"井下变电所低压馈电开关跳闸后，重新送电前应先完成的确认工作是","options":["核对负荷侧无短路并检查漏电闭锁是否复位","拉开隔离开关后直接合闸试送一次","把漏电保护整定值调大后送电观察","通知采区电工在开关旁看守后送电"],"answer":[0],"explanation":"知识点：低压馈电开关跳闸后的送电程序。正确项对：必须先确认负荷侧无短路故障，并确认漏电闭锁已复位，才具备送电条件。错误项错在：拉开隔离开关直接试送属于带故障强行送电；调大整定值会掩盖真实故障；派人看守不能替代故障确认与闭锁复位。"},{"id":87,"type":"single","stem":"井下电气设备检修时，验电确认无电后对可能反送电的电缆应采取的下一步措施是","options":["对地放电并三相短接接地","用绝缘胶带包好电缆芯线","挂上“有人工作”标志牌","测量绝缘电阻确认无电"],"answer":[0],"explanation":"知识点：检修停电后的安全技术措施顺序。正确项对：验电后必须立即对地放电，并将三相短接接地，防止反送电和剩余电荷伤人。错误项错在：包绝缘胶带不能防止突然来电；挂标志牌属于警示措施而非防反送电措施；测绝缘电阻不能替代放电接地。"},{"id":88,"type":"single","stem":"矿用隔爆型电气设备隔爆外壳上的紧固螺栓缺少一颗时，正确的处理方式是","options":["用规格和强度等级相同的螺栓补全并拧紧","临时用铁丝穿过螺栓孔绑扎固定","只拧紧剩余螺栓并尽快安排补装","在缺失处涂密封胶后继续运行"],"answer":[0],"explanation":"知识点：隔爆外壳完整性的要求。正确项对：必须用规格和强度等级相同的螺栓补全并按规定拧紧，才能保证隔爆性能。错误项错在：铁丝无法保证隔爆间隙和强度；缺螺栓会破坏隔爆面配合，不能靠拧紧其余螺栓凑合；密封胶不能替代紧固件。"},{"id":89,"type":"single","stem":"井下电缆与压风管在同一巷道同侧敷设时，电缆应布置在管道的","options":["上方并保持规定间距","下方并紧贴管道","同一高度并排紧靠","下方并保持规定间距"],"answer":[0],"explanation":"知识点：井下电缆与管路的敷设位置关系。正确项对：电缆应敷设在管道上方并保持规定间距，防止管路漏水或检修时损伤电缆。错误项错在：布置在下方易受管路滴水、碰撞影响；紧贴管道不利于散热和检修；同高并排紧靠不满足间距要求。"},{"id":90,"type":"single","stem":"井下电气设备保护接地网上任意一保护接地点的接地电阻值，其检测周期最长不得超过","options":["每月一次","每季度一次","每半年一次","每年一次"],"answer":[1],"explanation":"知识点：井下保护接地电阻的检测周期。正确项对：任意一保护接地点的接地电阻应每季度测定一次。错误项错在：每月一次过于频繁，不是规定周期；每半年和每年一次均超过规定的最长周期，不能及时发现接地电阻超标。"},{"id":91,"type":"single","stem":"井下检漏保护装置动作使馈电开关跳闸后，未查明原因前正确的处置是","options":["允许试送一次以判断是否为瞬时故障","将检漏保护退出运行后送电","把动作电流整定值调高后送电","等待调度同意后直接恢复送电"],"answer":[0],"explanation":"知识点：漏电保护的运行管理。正确项对：漏电跳闸后允许试送一次，以判断是否为瞬时性故障，若再次跳闸必须查明原因。错误项错在：退出检漏保护运行属于甩保护；调高整定值会降低保护灵敏度；调度同意不能替代故障查明。"},{"id":92,"type":"single","stem":"井下用摇表测量电缆绝缘电阻时，测量结束后应先进行的操作是","options":["将电缆对地放电后再拆线","直接用手取下测量接线","先停摇表再立即拆线","把摇表转速降到最低后拆线"],"answer":[0],"explanation":"知识点：绝缘电阻测量的收尾操作。正确项对：测量结束后电缆上存有残余电荷，必须先对地放电再拆除接线。错误项错在：直接用手取线可能遭电击；先停摇表立即拆线仍存在残余电荷；降低转速不能消除电荷。"},{"id":93,"type":"single","stem":"井下局部通风机供电线路中，实现“三专”供电的含义是","options":["专用变压器、专用开关、专用电缆","专用线路、专用开关、专用保护","专用变压器、专用线路、专用开关","专用电缆、专用保护、专用开关"],"answer":[0],"explanation":"知识点：局部通风机“三专”供电的构成。正确项对：“三专”指专用变压器、专用开关、专用电缆。错误项错在：把专用线路、专用保护混入组合，或漏掉专用变压器、专用电缆，均不符合“三专”的完整含义。"},{"id":94,"type":"single","stem":"井下电工在采区变电所内更换馈电开关时，停电操作票上应首先明确的停电范围是","options":["该开关的电源侧和负荷侧均停电","只停该开关的负荷侧","只停该开关的电源侧","由上一级变电所统一停电"],"answer":[0],"explanation":"知识点：电气设备更换的停电范围确定。正确项对：更换开关必须使其电源侧和负荷侧均可靠停电，防止两侧来电。错误项错在：只停一侧会留下另一侧来电风险；由上一级统一停电不等于本开关两侧均已停电，范围不明确。"},{"id":95,"type":"single","stem":"井下某采区照明综保装置频繁动作，电工检查发现负荷侧电缆有一处破损受潮，正确的处置环节是","options":["更换破损电缆并测试绝缘合格后恢复送电","把综保动作值调大后恢复送电","将破损处用绝缘胶带缠绕后送电","暂时退出综保并加强巡视后送电"],"answer":[0],"explanation":"知识点：综合保护装置频繁动作的故障排查与处置。正确项对：应更换破损受潮电缆，测试绝缘合格后再恢复送电。错误项错在：调大动作值会掩盖故障；胶带缠绕不能恢复受潮电缆的绝缘性能；退出综保属于甩保护运行。"},{"id":96,"type":"multi","stem":"井下电气设备入井前应进行的检查项目中，属于必须确认的有","options":["产品合格证和矿用产品安全标志齐全","隔爆外壳无裂纹、无变形且隔爆面完好","设备内部接线端子紧固、无松动","设备外观颜色与巷道标识一致","设备铭牌上的功率与负载匹配"],"answer":[0,1,2],"explanation":"知识点：矿用电气设备入井前的检查要求。正确项对：安全标志与合格证、隔爆外壳及隔爆面完好、内部接线紧固均直接关系防爆与运行安全，必须确认。错误项错在：外观颜色与巷道标识一致不属于入井安全必检项；铭牌功率与负载匹配属于选型校核内容，不是入井前必须确认的防爆安全项。"},{"id":97,"type":"single","stem":"井下变电所内检漏继电器动作后，在恢复送电前应先做的操作是","options":["按下试验按钮验证继电器动作是否可靠","直接合上总开关试送一次观察是否再跳","断开所有分路开关后逐路试送查找故障支路","将检漏继电器退出运行后合闸送电"],"answer":[2],"explanation":"知识点：漏电闭锁后的故障排查程序。正确项先断开全部分路再逐路试送，可定位故障支路，避免带故障强行送电。按下试验按钮只是校验继电器本身，不能排查线路故障；直接试送可能扩大事故；退出检漏继电器运行属严重违章，会失去漏电保护。"},{"id":98,"type":"single","stem":"井下电气设备隔爆外壳的隔爆结合面涂油时，应选用的涂抹方式是","options":["涂一层薄防锈油脂并保持清洁","涂满厚黄油以填平间隙","涂导电膏降低接触电阻","涂机油后擦干不留油膜"],"answer":[0],"explanation":"知识点：隔爆结合面的维护要求。正确项薄涂防锈油脂既防锈又不影响隔爆间隙。厚黄油会改变隔爆间隙并粘附粉尘；导电膏用于电气连接处而非隔爆面；涂后擦干失去防锈作用。"},{"id":99,"type":"single","stem":"井下低压橡套电缆在巷道内悬挂时，电缆与风水管同侧敷设且间距不足，正确的处理是","options":["将电缆改挂在风水管上方并保持规定间距","用铁丝把电缆与风水管绑扎在一起固定","把电缆盘绕在风水管上减少占用空间","将电缆埋入巷道底板下穿过该段"],"answer":[0],"explanation":"知识点：井下电缆敷设与管线的位置关系。正确项是改挂上方并保持间距，避免管路检修损伤电缆。绑扎在一起会使电缆受振动磨损；盘绕在管上易受潮受机械损伤；埋入底板不符合井下电缆敷设要求。"},{"id":100,"type":"single","stem":"井下移动变电站高压侧电缆连接器在运行中出现轻微放电声，正确的处置是","options":["停电后检查连接器内部受潮或接触不良并处理","在运行中用绝缘杆按压连接器消除放电","提高该回路负荷使放电声被掩盖","在连接器外部缠绕绝缘胶带继续运行"],"answer":[0],"explanation":"知识点：高压连接器异常放电的判断与处理。正确项是停电检查受潮或接触不良。带电按压极其危险；提高负荷不能消除放电；外部缠胶带无法解决内部绝缘缺陷。"},{"id":101,"type":"single","stem":"井下电气设备保护接地网的接地电阻定期测定周期，通常要求是","options":["每季度至少测定一次","每月至少测定一次","每年至少测定一次","每三年至少测定一次"],"answer":[0],"explanation":"知识点：井下保护接地电阻的检测周期。正确项为每季度至少一次。每月过于频繁不经济；每年和每三年间隔过长，不能及时发现接地网锈蚀断开。"},{"id":102,"type":"single","stem":"井下照明变压器二次侧应采用的安全供电方式是","options":["中性点不接地并装设漏电保护","中性点直接接地并装设熔断器","中性点经电阻接地并取消漏电保护","中性点不接地且不设任何保护"],"answer":[0],"explanation":"知识点：井下照明变压器的供电安全要求。正确项为中性点不接地并设漏电保护。直接接地会增大触电危险；经电阻接地并取消漏电保护失去保护作用；不设保护属严重缺陷。"},{"id":103,"type":"single","stem":"井下电气作业人员在检修中需要短时离开已停电并挂牌的开关，返回后继续作业前应","options":["重新验电确认无电后再开始作业","核对挂牌位置无误后直接作业","询问值班人员是否送电后作业","查看开关分闸指示灯后作业"],"answer":[0],"explanation":"知识点：停电作业间断后的安全确认。正确项要求重新验电，防止期间被他人误送电。核对挂牌、询问值班、看指示灯均不能替代验电。"},{"id":104,"type":"single","stem":"井下隔爆型电动机运行中轴承温度异常升高，且伴有异味，正确的下一步操作是","options":["停机检查轴承润滑和装配状况","继续运行并加强通风降温","补充润滑脂后维持原负荷运行","降低电压运行观察温度变化"],"answer":[0],"explanation":"知识点：隔爆电动机轴承异常的处置。正确项为停机检查润滑与装配。继续运行会烧毁轴承；仅补脂不查装配不能消除故障；降低电压与轴承故障无直接关系。"},{"id":105,"type":"single","stem":"井下电气设备隔爆外壳紧固螺栓缺少一枚时，正确的处理是","options":["用相同规格和强度的螺栓补全后送电","用稍长的普通螺栓代替缺失螺栓","暂时减少该处密封垫后送电","用铁丝穿过螺栓孔临时固定"],"answer":[0],"explanation":"知识点：隔爆外壳紧固件完整性要求。正确项为用同规格同强度螺栓补全。普通螺栓强度不符；减少密封垫破坏隔爆性能；铁丝固定不符合紧固要求。"},{"id":106,"type":"single","stem":"井下电缆连接采用冷压接线端子时，压接后应检查的项目是","options":["压接牢固并测量绝缘电阻合格","端子表面涂漆防锈后即可","压接后用力拉扯导线确认不脱","压接后立即通额定电流试验"],"answer":[0],"explanation":"知识点：电缆冷压连接的质量检查。正确项为压接牢固并测绝缘电阻。涂漆影响导电和检查；拉扯不能替代绝缘检测；直接通额定电流试验风险大且不规范。"},{"id":107,"type":"multi","stem":"井下电气设备检修中，属于停电安全措施的内容有","options":["断开电源并验电确认无电","在开关操作把手上悬挂停电警示牌","对可能反送电的回路装设接地线","检修完成后由检修人员自行摘牌送电","在带电设备外壳上直接进行检修"],"answer":[0,1,2],"explanation":"知识点：停电检修安全措施。正确项包括停电验电、挂牌、装设接地线。自行摘牌送电违反谁挂牌谁摘牌原则；在带电外壳上检修属违章作业。"},{"id":108,"type":"single","stem":"井下变电所内检漏继电器动作后，经查为某支路电缆绝缘受潮，在恢复送电前应优先完成的操作是","options":["对该支路电缆摇测绝缘电阻并确认合格","将该支路负荷改接到相邻备用开关","把检漏继电器整定值临时调大后试送","对该支路电缆送电空载运行观察"],"answer":[0],"explanation":"知识点：漏电故障处置程序。检漏继电器动作说明存在漏电或绝缘下降，必须先查明并消除故障，摇测绝缘合格后才能送电。改接负荷只是转移问题未消除隐患；调大整定值会掩盖故障；空载试送仍可能引发漏电事故。"},{"id":109,"type":"single","stem":"井下电气设备隔爆外壳的隔爆接合面出现轻微锈蚀时，正确的处理方式是","options":["用砂纸打磨除锈后涂薄层防锈油","用棉纱擦净锈迹后直接装配使用","涂一层油漆覆盖锈斑防止继续氧化","用扁铲铲除锈层并加厚密封垫"],"answer":[0],"explanation":"知识点：隔爆接合面维护。轻微锈蚀可用砂纸打磨并涂防锈油，保持接合面间隙和光洁度。棉纱擦净不能去除氧化层；涂油漆会增大间隙、影响隔爆性能；加厚密封垫会改变隔爆间隙，均属错误做法。"},{"id":110,"type":"single","stem":"井下低压电缆接线盒内芯线连接采用压接方式时，压接后应做的检查是","options":["测量接头处的接触电阻是否超标","用手拉拽芯线检查是否松动","观察压接管的颜色是否变色","测量接头对地绝缘电阻是否为零"],"answer":[0],"explanation":"知识点：电缆接头质量检验。压接质量主要看接触电阻，接触电阻超标会发热。手拉拽不能反映真实接触状况；压接管变色与压接质量无直接对应；对地绝缘为零是接地故障判断，不是压接质量检查方法。"},{"id":111,"type":"single","stem":"井下照明变压器二次侧采用不接地系统时，照明灯具的金属外壳应采取的接地措施是","options":["经照明电缆芯线接到局部接地极","就近接到巷道金属支护上","与照明变压器二次侧中性点连接","利用铠装电缆钢带作为接地线"],"answer":[0],"explanation":"知识点：井下不接地系统照明接地。二次侧不接地时，灯具金属外壳需经专用接地芯线接局部接地极。接金属支护不能保证接地电阻稳定；接中性点不适用于不接地系统；钢带是屏蔽铠装层，不能作接地线。"},{"id":112,"type":"single","stem":"井下电气检修中需要停高压开关柜时，验电环节的正确操作是","options":["在开关柜进出线两侧分别验电","只在负荷侧验电即可确认无电","用声光验电器在柜门外验电","验电前先合上接地开关再验电"],"answer":[0],"explanation":"知识点：高压停电验电程序。可能来电侧包括进出线两侧，必须分别验电。只验负荷侧漏掉电源侧；柜门外验电不能确认内部带电状态；先合接地开关再验电顺序颠倒，可能带电合接地开关。"},{"id":113,"type":"single","stem":"井下移动变电站高压侧电缆连接器在运行中出现温度偏高，最应先排查的环节是","options":["连接器插接面接触是否良好","变压器油位是否低于规定值","低压侧负荷是否超过额定容量","电缆外护套是否被挤压变形"],"answer":[0],"explanation":"知识点：电缆连接器过热原因。连接器温度偏高多因插接面接触不良导致接触电阻增大。油位影响变压器散热整体；低压侧过载会整体升温但非连接器局部过热；护套变形影响绝缘而非直接引起接头过热。"},{"id":114,"type":"single","stem":"井下电气设备安装中，隔爆开关的电缆引入装置密封圈内径与电缆外径的配合要求是","options":["密封圈内径与电缆外径差不超过1毫米","密封圈内径应大于电缆外径2毫米以上","密封圈内径应小于电缆外径以便压紧","密封圈内径与电缆外径差不超过3毫米"],"answer":[0],"explanation":"知识点：隔爆电缆引入装置密封要求。密封圈内径与电缆外径差应不大于1毫米，保证紧密配合。大于2毫米或3毫米会留缝隙失去隔爆作用；小于外径则无法套入或压坏密封圈。"},{"id":115,"type":"single","stem":"井下电气作业中，使用钳形电流表测量电缆电流时，正确的做法是","options":["将被测导线置于钳口中央并保持钳口闭合","把两根相线同时夹入钳口读取数值","在钳口张开状态下读取稳定数值","把钳形表固定在电缆上长期监测"],"answer":[0],"explanation":"知识点：钳形电流表使用。测量时应将单根导线置于钳口中央、钳口闭合。夹两根相线读数为矢量和；钳口张开时磁路不闭合读数不准；固定在电缆上长期监测不符合仪表使用要求。"},{"id":116,"type":"single","stem":"井下接地网中，局部接地极采用钢管垂直埋设时，钢管埋入深度和露出地面的要求是","options":["埋深不少于0.75米，管口露出地面适量","埋深不少于0.3米，管口与地面齐平","埋深不少于1.5米，管口露出地面0.5米","埋深不少于0.5米，管口埋入地下即可"],"answer":[0],"explanation":"知识点：局部接地极埋设要求。钢管垂直埋设时埋深一般不少于0.75米，管口露出地面便于检查连接。0.3米、0.5米过浅，接地电阻不稳；1.5米埋深过大不便于检查维护。"},{"id":117,"type":"single","stem":"井下电气设备检修完成后送电前，确认设备内部无遗留工具和材料的直接有效方法是","options":["打开检修盖板目视检查内部并清点工具","查询检修记录本上的完工签字","询问参与检修人员是否收拾干净","测量设备绝缘电阻是否达到规定值"],"answer":[0],"explanation":"知识点：检修完工检查。送电前应打开盖板目视检查内部并清点工具，直接确认无遗留物。查记录和询问不能替代实物检查；测绝缘电阻只能反映绝缘状况，不能发现遗留金属工具。"},{"id":118,"type":"single","stem":"井下某采区配电点，一名电工在未办理停电手续的情况下准备紧固一台运行中开关的接线螺栓，班组长发现后正确的处置是","options":["立即制止并令其办理停电、验电、挂牌后再作业","允许其戴绝缘手套快速紧固一颗螺栓","要求其站在绝缘垫上完成紧固作业","让其先用验电笔确认外壳不带电后作业"],"answer":[0],"explanation":"知识点：带电作业禁令与停电作业程序。运行中开关接线螺栓带电，必须停电、验电、挂牌后作业。戴绝缘手套、站绝缘垫、验外壳均不能替代停电程序，属于违章冒险作业。"},{"id":119,"type":"multi","stem":"井下电气设备隔爆性能检查中，下列属于必须判为失爆的情形有","options":["隔爆外壳出现裂纹或明显变形","隔爆接合面间隙超过规定值","电缆引入装置密封圈老化失去弹性","外壳表面油漆局部脱落露出金属","紧固螺栓缺少弹簧垫圈但已拧紧"],"answer":[0,1,2],"explanation":"知识点：失爆判定。外壳裂纹变形、接合面间隙超标、密封圈老化失效均直接破坏隔爆性能，判为失爆。表面油漆脱落只影响防腐；缺弹簧垫圈但已拧紧需进一步判断，不直接等同失爆。"},{"id":120,"type":"single","stem":"井下变电所检修低压馈电开关时，验电确认无电后还应进行的一项关键操作是","options":["对地放电并挂接地线","测量绝缘电阻确认无电","合上隔离开关泄放残压","用万用表复测三相电压"],"answer":[0],"explanation":"知识点：停电检修的安全技术措施。验电只能证明当前无电，但电缆或电容器可能储存电荷，必须对地放电并装设接地线才能防止突然来电和残余电荷伤人。测量绝缘电阻是检修中的测试项目，不能代替放电接地；合上隔离开关可能造成反送电；万用表复测电压只能再次验电，不能泄放残余电荷。"},{"id":121,"type":"single","stem":"井下低压电网中，漏电保护装置动作后，电工查找故障点前应做的是","options":["先断开该回路总开关并挂牌","直接复位漏电保护试送电","将漏电保护退出运行再送电","测量负荷电流判断是否过载"],"answer":[0],"explanation":"知识点：漏电保护动作后的处置程序。漏电动作说明回路存在绝缘故障，必须先断开该回路电源并挂牌，防止误送电，再查找故障点。直接复位或退出保护送电可能造成触电或短路事故；测负荷电流与漏电故障查找无直接关系。"},{"id":122,"type":"single","stem":"井下电缆与电气设备连接时，采用铜铝过渡接头的目的是","options":["防止铜铝接触处电化学腐蚀","提高接头处机械强度","降低接头处接触电阻至零","便于接头处绝缘包扎"],"answer":[0],"explanation":"知识点：铜铝连接的电化学腐蚀问题。铜铝直接连接在潮湿环境中会形成原电池，产生电化学腐蚀，导致接触电阻增大发热，故用铜铝过渡接头。过渡接头不能使接触电阻为零，主要目的也不是提高机械强度或便于包扎。"},{"id":123,"type":"single","stem":"井下接地网中，电气设备金属外壳与接地极的连接线应满足的要求是","options":["采用有机械保护的接地干线","采用任意截面铜芯软线","与设备外壳点焊固定","经开关外壳串联后接地"],"answer":[0],"explanation":"知识点：井下保护接地连接要求。设备外壳应通过有机械保护的接地干线可靠接地，防止机械损伤和连接松动。任意截面软线、点焊固定、串联接地均不符合可靠性和独立性要求。"},{"id":124,"type":"single","stem":"井下电气设备检修完成后送电前，必须确认的一项是","options":["所有检修人员已撤离并拆除接地线","设备外壳已擦拭干净","运行记录已填写完毕","备品备件已清点入库"],"answer":[0],"explanation":"知识点：检修后送电条件。送电前必须确认检修人员全部撤离、接地线全部拆除、工具材料清理完毕，防止人身和设备事故。擦拭外壳、填写记录、清点备件是辅助工作，不是送电前的安全确认条件。"},{"id":125,"type":"single","stem":"井下移动式电气设备橡套电缆发生局部破损，露出芯线但未断，正确的处理是","options":["立即停电并更换或热补处理","用绝缘胶带缠绕后继续使用","将该段电缆盘起架空使用","降低负荷继续运行至检修班"],"answer":[0],"explanation":"知识点：橡套电缆破损处置。芯线外露存在短路和触电风险，必须停电处理，更换或按规定热补。绝缘胶带缠绕不能恢复电缆的机械强度和绝缘性能，盘起架空和降负荷运行均不能消除隐患。"},{"id":126,"type":"single","stem":"井下电气作业中，操作高压开关柜停电时，正确的顺序是","options":["先断开断路器，再拉开隔离开关","先拉开隔离开关，再断开断路器","同时断开断路器和隔离开关","先合接地开关，再断开断路器"],"answer":[0],"explanation":"知识点：高压开关操作顺序。停电时应先断开断路器切断负荷电流，再拉开隔离开关隔离电源。先拉隔离开关会造成带负荷拉闸，产生电弧；同时操作和先合接地开关均违反操作程序。"},{"id":127,"type":"single","stem":"井下某掘进工作面照明开关频繁跳闸，复位后可短时运行又跳，最可能的故障环节是","options":["照明电缆或灯具存在间歇性漏电","照明变压器容量偏小","照明开关额定电流偏小","供电电压略低于额定值"],"answer":[0],"explanation":"知识点：漏电保护频繁动作的故障分析。复位后能短时运行又跳闸，说明回路存在间歇性漏电或绝缘不良，应停电分段查找。容量偏小、电压偏低通常表现为过载或亮度不足，不会引起漏电保护反复动作。"},{"id":128,"type":"multi","stem":"井下电气设备检修中，下列属于必须停电作业的情形有","options":["更换隔爆开关内部接线端子","检查运行中电机的外壳温度","测量停电电缆的绝缘电阻","紧固带电运行的开关母线螺栓","清理隔爆面并涂防锈油脂"],"answer":[0,2,4],"explanation":"知识点：停电作业范围。更换内部接线端子、测量停电电缆绝缘、清理隔爆面均需停电进行。检查运行中电机外壳温度可在运行中通过测温方式进行，紧固带电母线螺栓属于带电作业，均不属于必须停电作业情形。"},{"id":129,"type":"single","stem":"井下低压橡套电缆在总接地网中，其接地芯线截面积最小应不小于","options":["4 mm²","6 mm²","10 mm²","16 mm²"],"answer":[2],"explanation":"知识点：井下低压电缆接地芯线最小截面要求。正确项为10 mm²。4 mm²、6 mm²、16 mm²均为常见相邻规格，若记不牢容易混选，实际低压橡套电缆接地芯线不得小于10 mm²。"},{"id":130,"type":"single","stem":"井下电气设备隔爆外壳上的紧固螺栓缺失后，正确的处置方式是","options":["用同规格普通螺栓临时紧固","用铁丝绑扎后维持运行","停电后补齐同规格隔爆螺栓","减少螺栓数量但加大紧固力矩"],"answer":[2],"explanation":"知识点：隔爆外壳完整性的基本要求。正确项停电补齐同规格螺栓，保证隔爆间隙和强度。普通螺栓强度不匹配；铁丝绑扎不具隔爆作用；少数螺栓加大力矩会造成壳体变形，均不能恢复隔爆性能。"},{"id":131,"type":"single","stem":"井下移动变电站高压侧检修时，验电后应优先执行的操作是","options":["装设接地线","挂警示牌","测量绝缘电阻","拆除母线连接"],"answer":[0],"explanation":"知识点：停电检修安全技术措施顺序。验电确认无电后应立即装设接地线，防止反送电和感应电伤人。挂警示牌、测绝缘、拆母线均在接地之后进行，顺序颠倒会留下触电风险。"},{"id":132,"type":"single","stem":"井下电气设备运行中闻到绝缘烧焦气味且外壳温度明显升高，值班电工下一步应","options":["加强通风继续观察负荷变化","停电检查并测量绝缘电阻","记录温度后交接班处理","降低设备负荷继续运行"],"answer":[1],"explanation":"知识点：电气设备异常发热与绝缘故障判断。正确项停电检查测绝缘，查明原因再送电。继续观察、交接班处理、降负荷运行都可能延误故障发展，导致短路或火灾。"},{"id":133,"type":"single","stem":"井下电缆连接采用冷压接线鼻子时，压接后正确的检查内容是","options":["接头表面涂绝缘漆","压接后测量接头直流电阻","检查压坑位置和压接牢固程度","用胶带缠绕压接部位"],"answer":[2],"explanation":"知识点：电缆冷压连接质量检查。正确项检查压坑位置、数量和牢固程度。涂绝缘漆、测直流电阻、缠胶带均不是冷压接头验收的关键检查点，压接不实会在运行中发热。"},{"id":134,"type":"single","stem":"井下电气作业中，携带式电气测量仪表使用前应重点确认的是","options":["仪表外壳颜色","仪表量程和电压等级","仪表生产厂家","仪表电池新旧"],"answer":[1],"explanation":"知识点：井下携带式仪表使用安全。正确项确认量程和电压等级与被测回路匹配。外壳颜色、厂家、电池新旧不影响测量安全，量程或电压等级不符会损坏仪表并引发事故。"},{"id":135,"type":"single","stem":"井下局部通风机供电线路中，实现风电闭锁的核心作用是","options":["风机停转时自动切断掘进工作面电源","风机启动时自动合上工作面照明","风机故障时自动切换备用风机","风机运行中自动调整风量大小"],"answer":[0],"explanation":"知识点：风电闭锁功能。正确项是风机停转时切断工作面电源，防止瓦斯积聚后电气设备引发事故。自动合照明、切换备用风机、调风量均不是风电闭锁的功能。"},{"id":136,"type":"single","stem":"井下电气设备保护接地网中，接地极与接地导线连接处正确的处理方式是","options":["用普通铁丝缠绕后埋入","焊接或使用专用接地夹连接","用绝缘胶带包裹后固定","直接搭接后回填土"],"answer":[1],"explanation":"知识点：接地装置连接要求。正确项采用焊接或专用接地夹，保证低电阻和机械强度。铁丝缠绕、绝缘包裹、直接搭接都会造成接地电阻增大或接触不良，不能形成可靠接地。"},{"id":137,"type":"single","stem":"井下变电硐室敷设电缆时，电缆与压风管、供水管在巷道同一侧悬挂，电缆应敷设在管道的什么位置？","options":["管道上方约0.3m处","管道下方约0.3m处","与管道同一水平面紧贴敷设","管道上方约1.0m处"],"answer":[0],"explanation":"知识点：井下电缆与管道的相对位置要求。电缆敷设在管道上方约0.3m处，可避免管道漏水、漏气侵蚀电缆，也便于检修。B项下方容易被管道渗漏损坏且不便维护；C项紧贴敷设易受管道振动和渗漏影响；D项1.0m间距过大，不符合规程要求的0.3m间距。"},{"id":138,"type":"single","stem":"井下电气设备检修需要停送电时，正确的操作顺序是？","options":["先停电、再验电、后放电、最后挂接地线","先验电、再停电、后放电、最后挂接地线","先停电、再挂接地线、后验电、最后放电","先放电、再停电、后验电、最后挂接地线"],"answer":[0],"explanation":"知识点：井下停送电安全操作程序。正确顺序为先停电切断电源、再验电确认无电、后对电容性设备放电、最后挂接地线，形成完整安全链。B项先验电时线路仍带电，验电无意义且危险；C项未验电就挂接地线，若线路带电会造成短路伤人；D项先放电时线路仍带电，操作人员直接接触有触电风险。"},{"id":139,"type":"single","stem":"井下低压电缆在水平巷道或倾斜巷道内悬挂时，悬挂点间距不得超过？","options":["3m","1m","5m","8m"],"answer":[0],"explanation":"知识点：井下电缆悬挂点间距规定。水平或倾斜巷道内电缆悬挂点间距不得超过3m，以保证电缆不因自重下垂过大而受损。B项1m间距过密，虽安全但不符合经济合理要求且非规程规定值；C项5m和D项8m间距过大，电缆下垂严重，易受车辆碰撞和自身拉力损坏。"},{"id":140,"type":"single","stem":"井下电气设备进行保护接地时，接地电阻值应满足的要求是？","options":["接地网上任一保护接地点的接地电阻不超过2Ω","接地网上任一保护接地点的接地电阻不超过4Ω","接地网上任一保护接地点的接地电阻不超过10Ω","接地网上任一保护接地点的接地电阻不超过0.5Ω"],"answer":[0],"explanation":"知识点：井下保护接地电阻要求。井下接地网上任一保护接地点的接地电阻不得超过2Ω，以确保漏电时能可靠动作。B项4Ω是地面电气设备接地的常见要求，井下条件更严格；C项10Ω过大，漏电电流不足以使保护装置动作；D项0.5Ω过于苛刻，实际难以达到且非规程要求值。"},{"id":141,"type":"single","stem":"井下电缆与风水管在巷道同一侧敷设时，若电缆与管道无法保持规定间距，应采取的措施是？","options":["在电缆与管道之间加设隔板或套管隔离","将电缆改为架空敷设在管道上方1.5m处","把电缆与管道用同一吊钩固定在一起","将电缆穿入钢管后与管道并排悬挂"],"answer":[0],"explanation":"知识点：电缆与管道间距不足时的隔离措施。当无法保持规定间距时，应在电缆与管道之间加设隔板或套管隔离，防止管道渗漏和机械损伤。B项1.5m间距过大且架空方式在井下难以实现；C项同一吊钩固定会使电缆承受管道振动和重量，且间距为零；D项钢管与管道并排仍无隔离，且钢管内穿电缆不便于检修。"},{"id":142,"type":"single","stem":"井下电气设备失爆的主要危害是？","options":["内部电弧或火花引燃周围爆炸性气体混合物","设备外壳温度过高烫伤操作人员","设备绝缘老化导致漏电电流增大","设备运行噪声超过井下允许标准"],"answer":[0],"explanation":"知识点：失爆的危害本质。失爆指防爆外壳失去隔爆性能，内部发生电弧或火花时不能阻止火焰向外传播，会引燃周围爆炸性气体混合物。B项外壳温度过高是另一类安全问题，不是失爆的核心危害；C项绝缘老化是漏电原因，与失爆机理不同；D项噪声属职业健康问题，与失爆无关。"},{"id":143,"type":"single","stem":"井下某采区变电所一台馈电开关频繁跳闸，电工到现场后首先应做的是？","options":["查看开关保护动作指示并询问操作人员跳闸前后情况","立即将保护整定值调大后试送电","拆开开关外壳检查内部接线是否松动","将该回路负荷切换到备用开关上运行"],"answer":[0],"explanation":"知识点：开关频繁跳闸的排查程序。首先应查看保护动作指示并了解跳闸前后情况，判断是过载、短路还是漏电动作，再针对性处理。B项擅自调大整定值会失去保护作用，可能导致事故扩大；C项未判断故障性质就拆壳检查，盲目且可能破坏现场信息；D项切换备用开关只是转移问题，未消除故障根源。"},{"id":144,"type":"multi","stem":"井下电气设备安装时，下列哪些做法符合防爆安全要求？","options":["防爆面紧固螺栓齐全并拧紧，弹簧垫圈压平","电缆引入装置密封圈内径与电缆外径匹配","防爆外壳表面有轻微锈蚀但不影响隔爆间隙","闲置的电缆引入口用厚度不小于2mm的金属堵板封堵","设备安装后防爆面涂少量凡士林防锈"],"answer":[0,1,3],"explanation":"知识点：防爆电气设备安装的防爆要求。A项紧固螺栓齐全拧紧、弹簧垫圈压平是保证隔爆面压紧的基本要求；B项密封圈内径与电缆外径匹配才能保证密封效果；D项闲置引入口用合格金属堵板封堵是防止爆炸性气体进入的必要措施。C项防爆面锈蚀会影响隔爆间隙和隔爆性能，即使轻微锈蚀也不允许；E项防爆面涂凡士林会改变隔爆间隙，影响隔爆性能，且油脂可能吸附杂质。"},{"id":145,"type":"single","stem":"井下变电硐室中，检漏继电器动作后，值班电工在未查明原因前应采取的措施是","options":["直接复位后继续送电观察","将检漏继电器退出运行后送电","锁定故障回路并排查绝缘","更换检漏继电器后试送电"],"answer":[2],"explanation":"知识点：检漏继电器动作后的处置。正确项对在必须先锁定故障回路、排查绝缘，防止带故障送电引发触电或爆炸。直接复位后继续送电错在未排查原因就恢复供电；将检漏继电器退出运行后送电错在失去漏电保护；更换检漏继电器后试送电错在未查绝缘就换件。"},{"id":146,"type":"single","stem":"井下电气设备的金属外壳与接地网连接时，接地线的连接方式应为","options":["螺栓压接并加防松垫","缠绕后涂防锈漆","点焊后包缠绝缘带","用扎带捆扎固定"],"answer":[0],"explanation":"知识点：井下接地线连接要求。正确项对在必须螺栓压接并加防松垫，保证接地连续可靠。缠绕后涂防锈漆错在接触电阻大且易松脱；点焊后包缠绝缘带错在焊接质量难控且绝缘带掩盖缺陷；用扎带捆扎固定错在机械强度不足。"},{"id":147,"type":"single","stem":"井下照明变压器二次侧中性点接地方式，通常应采用","options":["中性点直接接地","中性点不接地","中性点经消弧线圈接地","中性点经避雷器接地"],"answer":[1],"explanation":"知识点：井下照明变压器中性点接地方式。正确项对在井下照明变压器二次侧中性点通常不接地，以限制单相接地电流。中性点直接接地错在增大触电和引爆风险；经消弧线圈接地错在井下照明系统一般不采用；经避雷器接地错在避雷器不是接地方式。"},{"id":148,"type":"single","stem":"井下电缆在巷道内悬挂敷设时，电缆与压风管、供水管同侧敷设的间距要求是","options":["保持0.1m以上","保持0.3m以上","保持0.5m以上","紧靠管路固定"],"answer":[1],"explanation":"知识点：井下电缆悬挂间距要求。正确项对在电缆与压风管、供水管同侧敷设时应保持0.3m以上间距。保持0.1m以上错在间距不足；保持0.5m以上错在数值偏大；紧靠管路固定错在易受管路影响。"},{"id":149,"type":"single","stem":"井下电气作业中，发现电缆着火时，首先应采取的措施是","options":["立即用水扑灭火源","切断着火电缆电源","用灭火器直接喷射","通知调度等待指令"],"answer":[1],"explanation":"知识点：电缆着火处置。正确项对在首先切断着火电缆电源，防止触电和火势扩大。立即用水扑灭火源错在带电灭火危险；用灭火器直接喷射错在未先断电；通知调度等待指令错在延误处置。"},{"id":150,"type":"single","stem":"井下电气设备保护接地网中，接地极与接地极之间的连接应采用","options":["串联连接","并联连接","混联连接","星形连接"],"answer":[1],"explanation":"知识点：接地网连接方式。正确项对在接地极之间应并联连接，保证接地电阻稳定。串联连接错在一处断开影响整体；混联连接错在井下一般不采用；星形连接错在不是接地极间标准连接方式。"},{"id":151,"type":"single","stem":"井下低压馈电线上，检漏保护装置与馈电开关的配合关系是","options":["检漏保护动作后馈电开关立即分闸","检漏保护动作后馈电开关延时分闸","检漏保护只报警不动作馈电开关","检漏保护动作后手动分断馈电开关"],"answer":[0],"explanation":"知识点：检漏保护与馈电开关配合。正确项对在检漏保护动作后馈电开关应立即分闸，切断故障回路。延时分闸错在延误切断；只报警不动作错在失去保护作用；手动分断错在不能自动切断。"},{"id":152,"type":"single","stem":"井下电气设备安装中，隔爆型电气设备的引入装置密封圈内径与电缆外径的配合要求是","options":["密封圈内径应大于电缆外径2mm","密封圈内径应与电缆外径一致","密封圈内径应小于电缆外径1mm","密封圈内径应大于电缆外径5mm"],"answer":[1],"explanation":"知识点：隔爆引入装置密封圈配合。正确项对在密封圈内径应与电缆外径一致，保证密封。大于2mm错在间隙过大失去隔爆；小于1mm错在无法安装；大于5mm错在间隙过大。"},{"id":153,"type":"multi","stem":"井下电气设备检修安全措施中，属于停电后必须完成的有","options":["验电确认无电压","装设接地线","悬挂检修警示牌","测试绝缘电阻合格","拆除接地线后送电"],"answer":[0,1,2],"explanation":"知识点：检修停电安全措施。正确项对在停电后必须验电、装设接地线、悬挂警示牌。测试绝缘电阻合格错在属于检修后恢复阶段；拆除接地线后送电错在属于送电前操作。"},{"id":154,"type":"single","stem":"井下变电所内一台低压馈电开关跳闸后，复位前首先应做的操作是","options":["查看开关显示屏有无故障代码并记录","直接合闸试送一次判断是否临时故障","拉开上级隔离开关后打开开关外壳检查","用万用表测量负荷侧电缆绝缘电阻"],"answer":[0],"explanation":"知识点：跳闸后的故障排查程序。正确项对：先读取记录故障信息是判断跳闸原因的第一步，为后续排查提供依据。错误项一错在未查明原因直接试送，可能扩大故障。错误项二错在未读故障信息就停电开壳，跳过了关键诊断环节。错误项三错在未先读取故障信息、未验电放电就测绝缘，程序颠倒且有触电风险。"},{"id":155,"type":"single","stem":"矿用隔爆型电气设备隔爆外壳的隔爆性能主要依靠","options":["外壳壁厚足够承受内部爆炸压力","接合面间隙和宽度阻止火焰传出","外壳内充惰性气体隔绝氧气","外壳表面涂覆耐弧绝缘涂层"],"answer":[1],"explanation":"知识点：隔爆原理。正确项对：隔爆外壳靠接合面的间隙和宽度使内部爆炸火焰冷却、不能引燃外部爆炸性气体。错误项一错在壁厚只保证强度不保证隔爆。错误项二错在充惰性气体是正压型等其他防爆型式原理。错误项三错在涂层与隔爆性能无关。"},{"id":156,"type":"single","stem":"井下电气设备检修中，验电操作的正确顺序是","options":["先验低压后验高压，先验近端后验远端","先验高压后验低压，先验远端后验近端","先验高压后验低压，先验近端后验远端","先验低压后验高压，先验远端后验近端"],"answer":[2],"explanation":"知识点：验电顺序。正确项对：应先验高压后验低压、先验近端后验远端，逐步确认无电。错误项一顺序均颠倒。错误项二仅远近端颠倒。错误项三仅高低压颠倒。"},{"id":157,"type":"single","stem":"井下接地网中，接地极与接地导线连接处最容易因腐蚀而失效的部位是","options":["接地导线与设备外壳的螺栓连接点","接地极与接地导线的焊接或压接点","接地导线中间的电缆桥架固定卡子","接地极露出地面的观测标识桩"],"answer":[1],"explanation":"知识点：接地装置腐蚀失效部位。正确项对：接地极与导线连接点处于土壤中，是电化学腐蚀最严重、最易失效的部位。错误项一错在螺栓连接点虽需检查但非腐蚀最重处。错误项二错在固定卡子不参与导电连接。错误项三错在标识桩不参与接地导通。"},{"id":158,"type":"single","stem":"井下低压检漏保护装置动作使馈电开关跳闸后，正确的处置是","options":["将检漏保护退出运行后恢复送电","查明并消除漏电点后再恢复送电","将检漏保护整定值调大后送电","对线路摇测绝缘合格后即可送电"],"answer":[1],"explanation":"知识点：漏电保护动作后处置。正确项对：必须找到并消除漏电点后才能恢复送电。错误项一错在退出保护属违章送电。错误项二错在调大整定值掩盖故障。错误项三错在仅测绝缘合格但不查明漏电原因仍可能复跳或带隐患运行。"},{"id":159,"type":"single","stem":"井下电气设备的保护接地，其接地电阻值应满足的要求是","options":["由接地极数量决定，越多越好无上限","不超过规定的允许值，越小越好","与设备容量成正比，容量大则允许值大","与电缆长度成正比，线路长则允许值大"],"answer":[1],"explanation":"知识点：保护接地电阻要求。正确项对：接地电阻应不超过规定允许值，且越小保护效果越好。错误项一错在无上限说法不成立。错误项二错在接地电阻与设备容量无关。错误项三错在接地电阻与电缆长度无关。"},{"id":160,"type":"single","stem":"井下电缆悬挂敷设时，电缆与压风管、供水管在同一侧时，电缆应设在管子的","options":["上方并保持规定间距","下方并保持规定间距","同一水平紧贴管子固定","管子上方紧贴管子固定"],"answer":[0],"explanation":"知识点：井下电缆悬挂规定。正确项对：电缆应设在管子上方并保持规定间距，防止管子漏水或检修时损伤电缆。错误项一错在下方易受漏水影响。错误项二错在紧贴固定无间距不符要求。错误项三错在紧贴无间距不符要求。"},{"id":161,"type":"single","stem":"井下电气设备运行中，电动机突然出现声音异常且电流表指示增大，首先应","options":["继续运行观察电流变化趋势","立即停机检查并报告","降低负荷维持运行","加大冷却水量继续运行"],"answer":[1],"explanation":"知识点：电动机异常运行判断。正确项对：声音异常且电流增大说明可能存在机械或电气故障，应立即停机检查。错误项一错在继续观察可能使故障扩大。错误项二错在降负荷运行不能消除故障。错误项三错在加大冷却无关根本原因。"},{"id":162,"type":"single","stem":"井下使用的电气设备，其防爆标志中“Ex”表示","options":["设备为矿用一般型","设备为防爆型电气设备","设备为隔爆型电气设备","设备为本质安全型电气设备"],"answer":[1],"explanation":"知识点：防爆标志含义。正确项对：Ex是防爆型电气设备的通用标志。错误项一错在矿用一般型标志不同。错误项二错在隔爆型有专门代号。错误项三错在本质安全型有专门代号。"},{"id":163,"type":"single","stem":"井下电气作业中，停电检修设备时，在开关操作手柄上悬挂的标示牌应写明","options":["止步，高压危险","有人工作，禁止合闸","在此工作，注意安全","设备检修，请勿靠近"],"answer":[1],"explanation":"知识点：检修安全标示牌。正确项对：停电检修时应在操作手柄悬挂“有人工作，禁止合闸”标示牌。错误项一错在“止步，高压危险”用于遮栏警示。错误项二错在“在此工作”用于工作地点标示。错误项三错在“请勿靠近”非标准检修标示。"},{"id":164,"type":"single","stem":"井下变电所内一台矿用一般型低压开关柜因受潮绝缘下降，检修后送电前应优先做的检验是","options":["用兆欧表测量主回路相间及相对地绝缘电阻","用万用表测量进出线端子通断","用钳形电流表测量空载电流","用接地电阻测试仪测量柜体接地电阻"],"answer":[0],"explanation":"知识点：送电前绝缘检验。受潮后绝缘下降，必须先测绝缘电阻判断能否送电。万用表测通断不能反映绝缘状况；钳形电流表测空载电流需送电后才有意义；接地电阻测试仪测的是接地系统电阻，不能判断主回路绝缘。"},{"id":165,"type":"single","stem":"金属非金属矿山井下巷道内敷设电缆时，电缆与压风管、供水管同侧布置的情况下应","options":["保持0.3m以上距离并敷设在管子上方","保持0.3m以上距离并敷设在管子下方","紧贴管子敷设以节省空间","与管子保持0.1m距离并平行敷设"],"answer":[0],"explanation":"知识点：井下电缆与管路的敷设间距和位置。电缆应敷设在管路的上方并保持足够间距，防止管路漏水结冰或检修时损伤电缆。敷设在下方或紧贴、间距不足都易受管路滴漏和检修影响。"},{"id":166,"type":"single","stem":"井下电气设备检修需要停送电时，防止误送电造成检修人员触电的关键措施是","options":["在开关操作把手上悬挂\"禁止合闸，有人工作\"标示牌并闭锁","在检修地点设置警戒线并安排专人看守","断开开关后立即开始检修并在检修结束后恢复送电","将检修情况口头通知相邻采区值班人员"],"answer":[0],"explanation":"知识点：停送电安全措施中的闭锁与挂牌。停电后必须在操作把手上闭锁并悬挂标示牌，防止他人误合闸。设警戒线不能防止误合闸；断开后不验电放电直接检修不安全且无闭锁；口头通知无强制约束力。"},{"id":167,"type":"single","stem":"井下低压馈电开关的漏电闭锁功能与漏电保护功能的区别在于漏电闭锁是","options":["开关合闸前检测到漏电时闭锁合闸","开关运行中检测到漏电时跳闸","漏电时发出声光信号但不跳闸","漏电时只闭锁上级开关"],"answer":[0],"explanation":"知识点：漏电闭锁与漏电保护的区别。漏电闭锁是在合闸前检测线路对地绝缘，若低于整定值则闭锁不能合闸；漏电保护是运行中检测到漏电后跳闸。选项B描述的是漏电保护；选项C是不跳闸只报警，不符合；选项D闭锁上级开关不正确。"},{"id":168,"type":"single","stem":"井下采用局部通风机供风的掘进工作面，因检修需要停止局部通风机运行时，正确的处置顺序是","options":["先撤出人员、切断电源，再停止局部通风机","先停止局部通风机，再撤出人员并切断电源","先切断动力电源，随即停止局部通风机","先停止局部通风机，随即恢复供电"],"answer":[0],"explanation":"知识点：掘进工作面停风的安全处置。停风前必须先撤出人员再停风，防止瓦斯积聚造成人员伤害。先停风再撤人会使人员处于无风危险环境；先切动力电源后停风顺序不当；停风后随即恢复供电更不能在人员未撤离时进行。"},{"id":169,"type":"single","stem":"井下电气设备隔爆外壳的隔爆性能主要依靠隔爆接合面的宽度、间隙和表面粗糙度来保证，检修后复装时隔爆接合面上","options":["允许涂少量防锈油但不得涂油漆","应涂防锈漆以防腐蚀","应涂润滑脂以减小间隙","应保持清洁并涂密封胶"],"answer":[0],"explanation":"知识点：隔爆接合面处理要求。隔爆接合面可以涂少量防锈油，但不得涂油漆、润滑脂或密封胶，否则会改变间隙和隔爆性能。涂防锈漆、涂润滑脂、涂密封胶都会破坏隔爆参数。"},{"id":170,"type":"single","stem":"井下低压电网中，检漏继电器动作后经排查未发现明显故障，值班电工再次试送电时正确的做法是","options":["查明原因并处理后方可送电，不得强行试送","试送一次观察是否再次动作","将检漏继电器退出运行后送电","提高检漏继电器整定值后送电"],"answer":[0],"explanation":"知识点：漏电保护动作后的处置。检漏继电器动作说明存在漏电或绝缘问题，必须查明并处理后方可送电，强行试送可能扩大事故。试送一次仍属强行送电；退出检漏继电器或提高整定值都是甩掉保护，属于严重违章。"},{"id":171,"type":"single","stem":"井下电气着火时，在电源尚未切断的情况下，正确的灭火处置是","options":["先切断电源，再用干粉或砂子灭火","直接用水扑救并同时切断电源","用泡沫灭火器扑救并等待电源自动跳闸","用二氧化碳灭火器扑救并保持电源供电"],"answer":[0],"explanation":"知识点：电气火灾灭火原则。带电灭火风险大，应先切断电源，再用干粉、砂子等不导电灭火剂灭火。直接用水或泡沫灭火器带电灭火会触电；等待自动跳闸不可靠；保持电源供电灭火更危险。"},{"id":172,"type":"single","stem":"井下移动式电气设备的橡套电缆在运行中受到挤压，外护套破损但芯线绝缘完好，正确的处置是","options":["立即停电并更换或修复电缆后再使用","用绝缘胶带缠绕破损处后继续使用","将破损处浸入防水胶后继续使用","降低设备负荷后继续使用"],"answer":[0],"explanation":"知识点：橡套电缆破损处置。外护套破损即使芯线绝缘完好也会降低防护能力，应停电更换或按规范修复。缠绕绝缘胶带、浸防水胶、降负荷使用都不能恢复电缆的机械和防护性能，属于带病运行。"},{"id":173,"type":"single","stem":"井下接地网中，主接地极与局部接地极之间的连接要求是","options":["用接地干线可靠连接形成接地网","各自独立接地互不连接","通过电缆金属护套连接即可","通过设备外壳串联连接"],"answer":[0],"explanation":"知识点：井下接地网连接。主接地极与局部接地极必须用接地干线可靠连接形成接地网，保证接地电阻合格。各自独立接地不能形成等电位；通过电缆护套或设备外壳串联连接不可靠且不符合要求。"},{"id":174,"type":"single","stem":"井下电气设备金属外壳与接地母线的连接，应采用的方式是","options":["用螺栓压接并加防松垫圈","用铜绑线缠绕后拧紧","用电焊点焊在支架上","用普通铁丝临时绑扎固定"],"answer":[0],"explanation":"知识点：井下保护接地连接必须可靠、防松、导电良好。正确项螺栓压接加防松垫圈能保证低电阻和抗振动；错误项铜绑线缠绕接触面积不足且易氧化松动；错误项点焊在支架上不保证与接地母线等电位；错误项铁丝电阻大、易锈蚀，不符合接地要求。"},{"id":175,"type":"single","stem":"井下低压电缆在巷道内悬挂敷设时，与电机车架空线的净距应保持的要求是","options":["不小于0.1m","不小于0.3m","不小于0.5m","不小于1.0m"],"answer":[1],"explanation":"知识点：井下电缆敷设需与架空线保持安全净距，防止电弧和机械损伤。正确项0.3m是常见要求；0.1m过近易发生放电；0.5m并非该处对应值；1.0m过大且不符合该处规定。"},{"id":176,"type":"single","stem":"井下电气设备检修时，验电环节的正确做法是","options":["用低压验电笔在开关负荷侧验电","用相应电压等级的验电器在停电设备各相分别验电","用万用表在开关电源侧测量有无电压","用手背轻触接线端子判断是否带电"],"answer":[1],"explanation":"知识点：检修停电后验电应使用电压等级匹配的验电器，并在各相分别验电。正确项符合程序；错误项低压验电笔电压等级不符且位置不对；错误项测电源侧不能确认设备是否带电；错误项人体触试严重违规且危险。"},{"id":177,"type":"single","stem":"井下局部通风机供电线路与掘进工作面电气设备之间，正确的供电关系是","options":["局部通风机可由掘进工作面动力变压器同一回路供电","局部通风机应实行三专供电并装设风电闭锁","局部通风机可与照明回路共用一条电缆","局部通风机停电时掘进工作面设备可继续运行"],"answer":[1],"explanation":"知识点：局部通风机必须三专供电并实现风电闭锁。正确项符合要求；错误项共用回路会导致风机停转时工作面仍带电；错误项与照明共用不满足专用要求；错误项风机停转后工作面设备继续运行会造成瓦斯积聚风险。"},{"id":178,"type":"single","stem":"井下电气设备隔爆外壳的隔爆结合面出现轻微锈蚀但未超过规定深度，正确的处理方式是","options":["用砂纸打磨后涂防锈油继续使用","用棉纱擦净后直接安装使用","用刮刀修整至平整后即可使用","更换该隔爆外壳或送修处理"],"answer":[3],"explanation":"知识点：隔爆结合面锈蚀会影响隔爆性能，需按规定处理。正确项更换或送修可保证隔爆性能；错误项砂纸打磨会改变结合面间隙；错误项擦净不消除锈蚀影响；错误项刮刀修整会破坏结合面尺寸。"},{"id":179,"type":"single","stem":"井下电缆连接采用的接线盒，其隔爆型式应满足的条件是","options":["与所连接电缆的电压等级和用途相适应","仅需与电缆截面相适应","仅需与电缆外径相适应","仅需与安装位置相适应"],"answer":[0],"explanation":"知识点：井下电缆接线盒的隔爆型式必须与电压等级、用途匹配。正确项满足适应要求；错误项只看截面、外径或位置不能保证隔爆和绝缘性能。"},{"id":180,"type":"single","stem":"井下变电所值班人员在巡视中发现高压开关柜内有异常放电声，正确的处置是","options":["立即打开柜门检查放电部位","立即断开该柜电源并报告调度","继续观察待放电声消失后再处理","先拉下隔离开关再打开柜门查看"],"answer":[1],"explanation":"知识点：发现高压设备异常放电应立即停电并报告。正确项先断电再报告；错误项带电开柜门可能触电；错误项继续观察会扩大故障；错误项带负荷拉隔离开关会产生电弧。"},{"id":181,"type":"single","stem":"井下电气设备保护接地网中，接地极与接地母线的连接方式应为","options":["焊接或螺栓压接","用钢丝绳绑扎","用电缆芯线缠绕","用普通铁丝绞接"],"answer":[0],"explanation":"知识点：接地极与接地母线连接必须牢固可靠、导电良好。正确项焊接或螺栓压接满足要求；错误项钢丝绳、电缆芯线缠绕、铁丝绞接均接触不良且易腐蚀松动。"},{"id":182,"type":"single","stem":"井下使用的电气设备中，属于矿用一般型设备的是","options":["矿用隔爆型电动机","矿用增安型接线盒","矿用一般型配电箱","矿用本质安全型电话"],"answer":[2],"explanation":"知识点：矿用一般型设备标志为KY，适用于无爆炸危险场所。正确项配电箱属矿用一般型；错误项隔爆型、增安型、本质安全型均属防爆型设备，用于有爆炸危险场所。"},{"id":183,"type":"single","stem":"井下电缆在水平巷道内敷设时，电缆与压风管、供水管平行敷设的净距应保持的要求是","options":["不小于0.1m","不小于0.3m","不小于0.5m","不小于1.0m"],"answer":[1],"explanation":"知识点：井下电缆与管路的敷设净距要求。正确项0.3m是常见规定；0.1m过近易受管路影响；0.5m和1.0m并非该处对应值。"},{"id":184,"type":"single","stem":"井下电气设备检修前，验电确认无电后，下一步应做的是","options":["立即开始拆卸接线端子","对可能来电侧装设接地线","挂牌并上锁后等待监护人到位","用万用表复测电压确认无电"],"answer":[1],"explanation":"知识点：检修停电安全程序。验电确认无电后必须先装设接地线（接地封线），防止反送电和残余电荷伤人。立即拆卸端子是验电后未接地就作业的常见错误；挂牌上锁属于停电后措施但应在验电接地前后按规定顺序执行，不能替代接地；万用表复测不是规程要求的接地步骤。"},{"id":185,"type":"single","stem":"井下低压馈电开关中，用于防止人身触电和漏电火灾的保护装置是","options":["过流保护装置","漏电保护装置","欠压保护装置","断相保护装置"],"answer":[1],"explanation":"知识点：井下低压保护功能辨析。漏电保护装置检测绝缘电阻下降和漏电电流，防止人身触电和漏电引发火灾。过流保护针对短路和过载；欠压保护防止电压过低运行；断相保护防止缺相运行烧电机，均不针对漏电。"},{"id":186,"type":"single","stem":"井下电气设备隔爆外壳隔爆面的紧固螺栓，检修后应","options":["涂少量润滑脂防锈后拧紧","涂防锈油后拧至弹簧垫圈压平","保持清洁干燥并按规定力矩拧紧","缠生料带密封后拧紧"],"answer":[2],"explanation":"知识点：隔爆面维护要求。隔爆面必须保持清洁干燥，不得涂油或加密封物，按规定力矩拧紧以保证隔爆间隙。涂润滑脂或防锈油会改变隔爆面间隙和传爆路径；缠生料带破坏隔爆面贴合，均属错误做法。"},{"id":187,"type":"single","stem":"井下巷道内敷设电缆时，电缆与压风管、供水管平行敷设的净距应不小于","options":["0.1米","0.3米","0.5米","1.0米"],"answer":[1],"explanation":"知识点：井下电缆敷设间距要求。电缆与压风管、供水管平行敷设时净距不小于0.3米，防止管路检修时损伤电缆。0.1米过近易受碰撞；0.5米和1.0米不是规程要求的数值。"},{"id":188,"type":"single","stem":"井下电工在检修一台正在运行的磁力启动器时，发现接触器主触头严重烧蚀，正确的处置是","options":["用细砂纸打磨触头后继续使用","更换同规格新触头并检查吸合情况","调整触头压力后送电观察","将烧蚀触头翻转180度安装使用"],"answer":[1],"explanation":"知识点：防爆电气设备触头检修。井下防爆设备触头烧蚀严重必须更换同规格新品，并检查吸合是否正常。打磨会减薄触头厚度、改变压力参数；调压后送电观察可能造成再次烧蚀甚至短路；翻转安装同触头仍烧蚀且隔爆性能无保障。"},{"id":189,"type":"single","stem":"井下变电所内检漏继电器动作后，值班电工首先应做的是","options":["立即手动复位后恢复送电","断开该回路电源并查明原因","短接检漏继电器临时送电","调整整定值后重新送电"],"answer":[1],"explanation":"知识点：漏电保护动作处置。检漏继电器动作说明存在漏电或绝缘下降，必须先断开回路电源查明原因。立即复位、短接、调大整定值都属于甩掉保护强行送电，是井下常见违章做法。"},{"id":190,"type":"single","stem":"井下电气设备外壳接地螺栓的规格要求是","options":["不小于M6","不小于M8","不小于M10","不小于M12"],"answer":[2],"explanation":"知识点：井下接地装置要求。电气设备外壳接地螺栓规格不小于M10，保证接地连接可靠。M6、M8偏小不能满足接地可靠性；M12虽更大但规程要求的下限是M10。"},{"id":191,"type":"single","stem":"某矿井下掘进工作面照明灯不亮，电工检查发现照明综合保护装置显示漏电闭锁，正确的下一步是","options":["按下试验按钮复位后送电","断开照明回路逐段排查绝缘","更换照明灯后直接送电","将该回路改接到动力变压器供电"],"answer":[1],"explanation":"知识点：漏电闭锁处置。漏电闭锁说明回路绝缘低于闭锁值，必须断开回路逐段排查绝缘，找到故障点处理后才能送电。复位按钮只能消除指示不能消除故障；换灯不解决线路漏电；改接到动力变压器供电属于甩保护违章。"},{"id":192,"type":"single","stem":"井下电气设备防爆标志中，ExdⅠ中的Ⅰ表示","options":["Ⅰ类煤矿用电气设备","Ⅰ类非煤矿山用电气设备","Ⅰ类工厂用电气设备","Ⅰ类船舶用电气设备"],"answer":[1],"explanation":"知识点：防爆标志含义。ExdⅠ中Ⅰ表示Ⅰ类非煤矿山用电气设备，对应金属非金属矿山井下环境。煤矿用设备为Ⅰ类但适用煤矿，工厂用为Ⅱ类，船舶用不属于该分类体系。"},{"id":193,"type":"multi","stem":"井下电气设备检修中，下列属于停电安全措施的有","options":["断开电源并验电确认无电","在可能来电侧装设接地线","悬挂检修停电警示牌","对设备外壳进行除锈刷漆","测量设备绝缘电阻并记录"],"answer":[0,1,2],"explanation":"知识点：停电检修安全措施。停电、验电、装设接地线、悬挂警示牌（必要时上锁）是保证检修安全的措施。除锈刷漆属于检修内容不是停电安全措施；测绝缘电阻是检修测试项目，也不属于停电安全措施。"},{"id":194,"type":"single","stem":"井下变电硐室中，一台矿用一般型变压器与一台矿用防爆型开关柜并排布置，巡视人员发现变压器外壳温度明显偏高，此时正确的做法是","options":["先拉开开关柜隔离开关，再检查变压器散热","先检查变压器负载电流和通风情况，再决定是否停电","先用水冲洗变压器外壳降温，再测量温度","先通知地面调度，等调度下令后再靠近检查"],"answer":[1],"explanation":"知识点：井下电气设备异常温度处置程序。变压器外壳温度偏高应先判明原因，检查负载电流、通风及冷却条件，再决定是否停电，盲目停电可能影响井下通风、排水等一级负荷。A项错在未判明原因即拉隔离开关，可能造成一级负荷失电；C项错在带电用水冲洗变压器外壳，极易造成短路和触电；D项错在未先做现场初步判断即等待调度，延误处置时机。"},{"id":195,"type":"single","stem":"井下变电硐室接地网中，主接地极与局部接地极的连接方式，正确的是","options":["主接地极与局部接地极分别独立埋设，不相互连接","局部接地极用电缆芯线串联后接至主接地极","主接地极与局部接地极用镀锌扁钢或钢绞线可靠连接成接地网","局部接地极只与设备外壳连接，不与主接地极连接"],"answer":[2],"explanation":"知识点：井下接地网连接要求。主接地极与局部接地极应用镀锌扁钢或钢绞线可靠连接，形成完整接地网，确保接地电阻满足要求。A项错在分别独立埋设不能形成等电位接地网；B项错在用电缆芯线串联，机械强度和截面均不满足接地要求；D项错在局部接地极不与主接地极连接，接地保护不完整。"},{"id":196,"type":"single","stem":"井下局部通风机供电线路中，实现“三专”供电中的“专用变压器”是指","options":["局部通风机与采煤机共用一台变压器","局部通风机与照明设备共用一台变压器","局部通风机由专用变压器供电，不与其他负荷共用","局部通风机由移动变电站经专用开关供电"],"answer":[2],"explanation":"知识点：局部通风机“三专”供电。三专指专用变压器、专用开关、专用线路，其中专用变压器要求只为局部通风机供电，不与其他负荷共用。A项错在与采煤机共用违反专用要求；B项错在与照明共用同样违反专用要求；D项错在描述的是专用开关和线路，不是专用变压器的定义。"},{"id":197,"type":"multi","stem":"井下电气设备检修中，下列做法符合安全要求的有","options":["检修前切断电源并验电、放电","在可能来电侧装设接地线并挂标示牌","检修完成后由原操作人恢复送电","带电搬迁移动式电气设备","检修时使用电压等级相符的验电器"],"answer":[0,1,4],"explanation":"知识点：井下电气检修安全措施。A项切断电源并验电、放电是检修前基本措施；B项装设接地线并挂标示牌可防止突然来电；E项使用电压等级相符的验电器是验电正确要求。C项错在送电应由专人按程序进行，不是简单由原操作人恢复；D项错在移动式电气设备搬迁必须停电，带电搬迁属违章。"},{"id":198,"type":"single","stem":"井下变电所内一台矿用变压器需要检修，停电操作票执行完毕后，验电确认无电，接下来应做的第一步是","options":["悬挂停电警示牌并上锁","对地放电并三相短接接地","用绝缘电阻表测量绕组绝缘","拆除变压器高低压侧接线"],"answer":[1],"explanation":"知识点：井下电气检修停电后的安全技术措施顺序。正确项对：验电无电后必须先对导体对地放电，再将三相短接并可靠接地，防止残余电荷和反送电伤人。A项错：挂警示牌上锁应在接地措施完成后进行，顺序颠倒。C项错：测绝缘属于检修内容，必须在接地措施完成且工作票许可后进行。D项错：拆接线是检修工序，未做接地前拆线有触电风险。"},{"id":199,"type":"single","stem":"井下低压馈电开关的漏电保护装置动作后，在未查明原因前值班电工的正确做法是","options":["按下复位按钮试送电一次观察","将漏电保护退出后临时送电","断开该回路并逐段查找故障点","把漏电动作值调大后送电"],"answer":[2],"explanation":"知识点：漏电保护动作后的处置程序。正确项对：漏电保护动作说明回路存在绝缘损坏或漏电，应断开回路、逐段排查，消除故障后才可送电。A项错：未查原因反复试送可能扩大事故。B项错：退出漏电保护属于甩保护运行，是严重违章。D项错：擅自调大动作值会降低保护灵敏度，掩盖故障。"},{"id":200,"type":"single","stem":"井下中央变电所的高压开关柜操作，停送电时应遵循的顺序是","options":["先合隔离开关，后合断路器","先合断路器，后合隔离开关","隔离开关与断路器同时合闸","只操作隔离开关即可完成停送电"],"answer":[0],"explanation":"知识点：高压开关操作顺序。正确项对：隔离开关不能带负荷操作，送电时应先合隔离开关（无负荷），后合断路器带负荷；停电顺序相反。B项错：先合断路器会造成隔离开关带负荷合闸，产生电弧。C项错：两者同时操作无法保证隔离开关无负荷。D项错：隔离开关无灭弧能力，不能单独用于带负荷停送电。"},{"id":201,"type":"single","stem":"井下电气设备选用时，对采掘工作面附近容易积聚瓦斯的场所，应优先选用的设备类型是","options":["普通开启式电气设备","矿用一般型电气设备","矿用隔爆型电气设备","矿用增安型电气设备"],"answer":[2],"explanation":"知识点：井下不同场所电气设备的选型。正确项对：瓦斯容易积聚场所必须选用隔爆型设备，内部爆炸时外壳能承受压力并阻止火焰外传。A项错：普通开启式设备无防爆能力，产生火花即可能引爆。B项错：矿用一般型不具备隔爆性能，不能用于有瓦斯爆炸危险的场所。D项错：增安型仅适用于正常时不产生火花的设备，不能替代隔爆型用于重点防爆区域。"},{"id":202,"type":"single","stem":"井下电缆与低压电气设备连接时，对电缆芯线与接线端子的连接要求是","options":["芯线弯成圆环后压紧在端子上","芯线直接插入端子孔拧紧即可","芯线搪锡后缠绕在端子上","芯线用绝缘胶带缠紧后塞入端子"],"answer":[0],"explanation":"知识点：井下电缆芯线与设备端子的连接工艺。正确项对：芯线应弯成与螺栓旋向一致的圆环，用垫圈压紧，保证接触良好、不松动。B项错：散股直接插入易压伤、接触不良、发热。C项错：缠绕连接接触电阻大，井下振动下易松脱。D项错：胶带塞入无机械紧固，属虚接，会发热甚至打火。"},{"id":203,"type":"single","stem":"井下电气设备隔爆外壳的隔爆面出现轻微锈蚀，检修时的正确处理是","options":["用砂纸打磨干净后涂防锈油","用棉纱擦净后直接装配使用","用油漆覆盖锈蚀处后装配","把隔爆面间隙适当加大再装配"],"answer":[0],"explanation":"知识点：隔爆面的维护要求。正确项对：隔爆面锈蚀应用砂纸或油石打磨除锈，清洗后涂防锈油，保持规定间隙和粗糙度。B项错：锈蚀未处理会破坏隔爆性能，仅擦净不够。C项错：油漆会改变隔爆面间隙和传爆性能，严禁涂漆。D项错：擅自加大间隙会破坏隔爆参数，导致失爆。"},{"id":204,"type":"single","stem":"井下接地网中，电气设备的金属外壳与接地极之间的连接线称为","options":["接地母线","接地引线","辅助接地线","接地干线"],"answer":[1],"explanation":"知识点：井下接地装置的组成与术语。正确项对：设备金属外壳与接地极（或接地母线）之间的连接线叫接地引线。A项错：接地母线是连接各接地极的主干线。C项错：辅助接地线是局部辅助接地极的连接线，不是外壳到接地极的那段。D项错：接地干线是接地网的主干导体，术语与引线不同。"},{"id":205,"type":"single","stem":"井下照明变压器二次侧采用不接地系统时，为限制人身触电电流，应装设的保护装置是","options":["过流保护","漏电保护","过压保护","断相保护"],"answer":[1],"explanation":"知识点：井下低压供电系统的漏电保护作用。正确项对：不接地系统发生单相触电时，漏电保护能迅速切断电源，限制触电电流和持续时间。A项错：过流保护针对短路和过载，对人身触电不起作用。C项错：过压保护防雷击和操作过电压，与触电电流限制无关。D项错：断相保护针对电动机缺相运行，不解决触电问题。"},{"id":206,"type":"single","stem":"井下电气设备检修需要停送电时，正确的停送电联系制度是","options":["由检修人员自行停送电","谁停电谁送电，并办理工作票","由值班员电话通知即可停送电","由班长口头同意后停送电"],"answer":[1],"explanation":"知识点：井下停送电管理制度。正确项对：必须执行工作票制度，坚持谁停电谁送电，防止误送电伤人。A项错：检修人员自行停送电无人监护，易发生误操作。C项错：仅电话通知无书面依据和确认，责任不清。D项错：口头同意无记录，不能作为停送电依据。"},{"id":207,"type":"single","stem":"井下某掘进工作面局部通风机突然停风，此时电工的正确处置是","options":["立即到工作面恢复通风机供电","先撤出人员并切断工作面电源","保持设备运行等待风流恢复","加大通风机负荷尽快恢复风量"],"answer":[1],"explanation":"知识点：停风后的安全处置。正确项对：停风后工作面可能积聚瓦斯，必须先撤人、切断工作面电源，再按规程恢复通风。A项错：未撤人先去恢复供电，人员可能进入瓦斯积聚区。C项错：停风后设备继续运行可能产生火花引爆瓦斯。D项错：停风时加大负荷不能恢复风量，还会损坏设备。"},{"id":208,"type":"single","stem":"井下变电所内对低压馈电开关进行停电检修时，验电确认无电后还应完成的操作是","options":["对电缆芯线逐相放电并接地","测量开关绝缘电阻后再操作","先合上隔离开关再挂标示牌","用万用表复核电压后直接作业"],"answer":[0],"explanation":"知识点：井下停电检修的验电、放电、接地程序。正确项对：验电后必须对可能残存电荷的电缆芯线逐相放电并接地，防止电容电荷伤人。错误项错在：测绝缘电阻属于检修项目而非停电安全措施；先合隔离开关等于送电；万用表复核不能替代放电接地。"},{"id":209,"type":"single","stem":"井下低压电网检漏保护装置动作切断电源后，在未查明原因前电工的正确做法是","options":["试送电一次观察是否再次动作","将该保护装置退出后送电","把漏电闭锁整定值调大后送电","用绝缘电阻表测负荷侧后送电"],"answer":[0],"explanation":"知识点：检漏保护动作后的处置程序。正确项对：可试送一次观察是否再次动作，以判断是瞬时故障还是持续故障，这是现场常用的排查步骤。错误项错在：退出保护属于甩保护运行；调大整定值会降低保护灵敏度；仅测绝缘电阻不能代替试送判断且未查明原因即送电。"},{"id":210,"type":"single","stem":"井下照明变压器的一次侧电压为380V，二次侧为127V，该变压器属于","options":["矿用一般型干式变压器","矿用隔爆型照明变压器","矿用增安型电力变压器","矿用本安型信号变压器"],"answer":[1],"explanation":"知识点：井下照明变压器按防爆型式的分类。正确项对：井下照明变压器通常为矿用隔爆型，配套127V照明回路，兼顾防爆与安全电压要求。错误项错在：一般型不能用于有瓦斯或粉尘爆炸危险的井下场所；增安型多用于接线盒等部件；本安型用于信号控制回路而非照明供电。"},{"id":211,"type":"single","stem":"井下电缆与设备连接时，电缆芯线与接线端子的连接应采用的工艺是","options":["芯线弯圈后压在端子垫圈下","芯线直接插入端子孔后拧紧","芯线镀锡后插入端子孔拧紧","芯线压接接线鼻子后接端子"],"answer":[3],"explanation":"知识点：井下电缆连接的工艺要求。正确项对：芯线应压接接线鼻子再与端子连接，保证接触面积和机械强度，防止松动发热。错误项错在：弯圈压接接触面小易氧化；直接插入易散股、接触不良；仅镀锡插入不能保证压紧防松。"},{"id":212,"type":"single","stem":"井下移动变电站高压侧停电后，在电缆上工作时除验电、放电、接地外还必须","options":["在操作手柄上挂停电作业牌","在电缆两端装设短路接地线","将变压器高压侧隔离开关拉开","设专人看守开关并悬挂标示牌"],"answer":[1],"explanation":"知识点：井下高压电缆检修的安全措施。正确项对：在电缆两端装设短路接地线可防止反送电和感应电伤人，是电缆作业的关键措施。错误项错在：仅挂牌不接地不能防反送电；仅拉开隔离开关未装接地线不完整；专人看守不能替代接地。"},{"id":213,"type":"single","stem":"井下电气设备运行中隔爆外壳温度超过规定值时，电工应优先采取的措施是","options":["加强通风降低环境温度后继续运行","停机检查过负荷或接触不良原因","在壳体外加装散热片后继续运行","降低设备负荷至额定值的80%运行"],"answer":[1],"explanation":"知识点：隔爆设备过热的原因判断与处置。正确项对：外壳超温多由过负荷、接触不良或散热不良引起，应先停机检查原因，消除隐患后再运行。错误项错在：只通风未查内因；加散热片不解决内部故障；降负荷运行掩盖故障继续带病运行。"},{"id":214,"type":"single","stem":"井下电气设备接地网上任意一点测得的接地电阻值，其要求是","options":["不大于1Ω","不大于2Ω","不大于4Ω","不大于10Ω"],"answer":[1],"explanation":"知识点：井下接地网接地电阻的限值要求。正确项对：井下接地网上任意一点测得的接地电阻不得大于2Ω，这是井下接地保护的基本要求。错误项错在：1Ω过于严格不是通用要求；4Ω为地面部分场所要求；10Ω远大于井下要求，起不到保护作用。"},{"id":215,"type":"single","stem":"井下低压馈电开关中，漏电闭锁与漏电保护的区别在于漏电闭锁","options":["只在合闸前检测绝缘并闭锁","只在合闸后检测并跳闸","动作后需人工复位才能合闸","动作后自动重合闸一次"],"answer":[0],"explanation":"知识点：漏电闭锁与漏电保护的功能区别。正确项对：漏电闭锁是在开关合闸前检测负荷侧绝缘，绝缘不合格时闭锁不能合闸，防止带故障送电。错误项错在：合闸后检测并跳闸属于漏电保护；人工复位是动作后的操作方式；自动重合闸不是漏电闭锁的特征。"},{"id":216,"type":"single","stem":"井下电气设备检修中需要更换隔爆接线盒内的密封圈时，新密封圈的内径应","options":["与电缆外径相同且能紧密配合","比电缆外径大1mm便于穿入","比电缆外径小1mm保证密封","按接线盒内径选配即可使用"],"answer":[0],"explanation":"知识点：隔爆密封圈的选配要求。正确项对：密封圈内径应与电缆外径相同并能紧密配合，保证隔爆性能和密封效果。错误项错在：大1mm会留缝隙失爆；小1mm难以穿入且易损伤电缆；按接线盒内径选配忽略电缆外径，无法密封。"},{"id":217,"type":"single","stem":"井下某采区变电所一台馈电开关频繁跳闸，电工现场检查发现负荷侧电缆有一处绝缘破损，正确的处置顺序是","options":["停电验电放电接地后处理破损并恢复绝缘","甩掉漏电保护后送电观察运行情况","调大过流整定值后送电继续使用","用绝缘胶带缠绕破损处后直接送电"],"answer":[0],"explanation":"知识点：井下电缆绝缘破损的处置程序。正确项对：应先停电、验电、放电、接地，再处理破损并恢复绝缘，确认合格后送电。错误项错在：甩保护运行属严重违章；调大整定值掩盖故障；未停电直接缠绕胶带带电作业危险且绝缘不可靠。"},{"id":218,"type":"single","stem":"井下低压配电系统中，检漏保护装置动作切断电源后，在恢复送电前应首先进行的操作是","options":["确认漏电故障已查明并处理后进行试送电","将检漏保护装置退出运行后直接合闸送电","反复合闸三次观察是否仍动作","把检漏保护整定值调大后合闸送电"],"answer":[0],"explanation":"知识点：漏电（检漏）保护动作后的处置程序。检漏保护动作说明存在漏电或绝缘降低，必须查明并处理故障点后才能试送电，故A正确。B退出保护送电属于甩保护运行，会失去漏电保护；C反复合闸会扩大故障、损坏设备；D调大整定值掩盖故障，均属错误做法。"},{"id":219,"type":"single","stem":"井下电气设备隔爆外壳隔爆面的紧固螺栓在检修后缺失一颗，正确的处置方式是","options":["用规格、性能相同的螺栓补齐后再投入运行","用普通铁质螺栓临时替代缺失的那一颗","用铁丝将外壳盖板绑扎固定后运行","减少该设备负荷后带缺陷继续运行"],"answer":[0],"explanation":"知识点：隔爆外壳完整性的检修要求。隔爆面靠紧固螺栓保证间隙和强度，缺失必须用相同规格性能的螺栓补齐，A正确。B普通螺栓强度、材质不符会破坏隔爆性能；C铁丝绑扎不能保证隔爆间隙；D减负荷与隔爆性能无关，缺陷仍存在。"},{"id":220,"type":"single","stem":"井下电缆在巷道内敷设时，与压风管、供水管同侧布置的正确做法是","options":["电缆敷设在管子上方并保持不小于0.3m的距离","电缆敷设在管子下方并紧贴管子固定","电缆与管子平行紧贴敷设以便于维护","电缆穿过管子下方并用同一种卡子固定"],"answer":[0],"explanation":"知识点：井下电缆与管路的敷设间距要求。电缆应敷设在管路的上方并保持规定间距，防止管路渗漏、检修时损伤电缆，A正确。B紧贴管子下方易受潮和碰伤；C平行紧贴不满足间距且相互干扰；D共用卡子固定会使电缆受管路振动和渗漏影响。"},{"id":221,"type":"single","stem":"井下电气检修作业中，停电后验电确认无电，接下来应按顺序完成的操作是","options":["装设接地线、悬挂警示牌、设置遮栏","悬挂警示牌、装设接地线、设置遮栏","设置遮栏、装设接地线、悬挂警示牌","装设接地线、设置遮栏、悬挂警示牌"],"answer":[0],"explanation":"知识点：检修停电安全技术措施顺序。正确顺序为验电后先装设接地线，再悬挂标示牌，最后设置遮栏，A正确。B先挂牌未接地，若突然来电无保护；C先设遮栏不能替代接地保护；D最后才挂牌，人员可能误合闸，顺序均不符合要求。"},{"id":222,"type":"single","stem":"井下使用的矿用变压器在投入运行前，除外观检查外还应重点确认的项目是","options":["绝缘电阻和接地连接是否符合要求","外壳油漆颜色是否与设计一致","铭牌上的出厂日期是否在有效期内","运输时使用的固定螺栓是否已涂油"],"answer":[0],"explanation":"知识点：矿用变压器投运前检查要点。投运前必须确认绝缘电阻合格、接地可靠，A正确。B油漆颜色与电气安全无关；C出厂日期不决定能否投运；D固定螺栓涂油属防锈维护，非投运关键条件。"},{"id":223,"type":"single","stem":"井下照明线路中，若发现某灯具外壳带电而照明仍正常，最可能的原因是","options":["灯具金属外壳保护接地失效且内部绝缘损坏","照明变压器容量偏小导致电压波动","灯具安装位置过高造成散热不良","照明线路截面偏大引起电压偏高"],"answer":[0],"explanation":"知识点：外壳带电的故障分析。外壳带电通常是内部绝缘损坏碰壳，同时保护接地失效，使外壳对地电位升高，A正确。B容量偏小表现为电压偏低、灯光变暗；C散热不良导致过热，不产生外壳带电；D截面偏大不会使电压偏高和外壳带电。"},{"id":224,"type":"single","stem":"井下电气设备进行防爆检查时，发现隔爆面有轻微锈蚀，正确的处理方法是","options":["用细砂布除去锈迹后涂薄层防锈油脂","用粗砂轮打磨至露出金属光泽","用煤油浸泡后直接擦干装机","用錾子剔除锈斑后补焊找平"],"answer":[0],"explanation":"知识点：隔爆面锈蚀的处理。轻微锈蚀应用细砂布除锈并涂防锈油脂，保持隔爆面间隙和光洁度，A正确。B粗砂轮打磨会破坏隔爆面精度；C煤油浸泡擦干不能除锈且残留油污；D錾子剔凿和补焊会改变隔爆面尺寸，均错误。"},{"id":225,"type":"single","stem":"井下电气作业中，电气设备着火且尚未停电时，正确的处置步骤是","options":["先切断电源，再用不导电的灭火器材灭火","直接用泡沫灭火器对准火焰根部喷射","先用水冲淋设备降温后再切断电源","用砂土覆盖设备后合闸检查着火点"],"answer":[0],"explanation":"知识点：电气火灾处置程序。电气火灾应首先切断电源，再使用不导电灭火器材，A正确。B泡沫灭火器导电，未断电使用有触电危险；C水导电且未先断电；D砂土覆盖前未断电且随后合闸检查会引发复燃和触电。"},{"id":226,"type":"single","stem":"井下移动式电气设备的橡套电缆在作业中被矿车碾压出护套破损但芯线未断，正确的处置是","options":["立即停止使用该设备并更换或修复电缆","用绝缘胶带缠绕破损处后继续使用","将破损处浸入防水胶中固化后使用","降低设备运行电流后继续使用"],"answer":[0],"explanation":"知识点：橡套电缆破损的处置。护套破损使绝缘和机械保护失效，必须停用并更换或按规范修复，A正确。B缠绕胶带不能恢复机械强度和防水性能；C涂胶固化同样不能满足井下防护要求；D降电流不解决护套破损隐患。"},{"id":227,"type":"single","stem":"井下变电所内高压开关柜检修时，在已停电并验电的柜内装设接地线，其接地端应连接在","options":["变电所的接地网上","开关柜的金属外壳油漆面上","邻近的运行中电缆铠装上","临时打入地下的短钢筋上"],"answer":[0],"explanation":"知识点：检修接地线的接地端连接要求。接地线应连接到变电所接地网，保证可靠接地，A正确。B油漆面绝缘，接地不可靠；C运行中电缆铠装不是检修接地端且可能带电；D临时短钢筋接地电阻无法保证，均不合格。"},{"id":228,"type":"single","stem":"井下某掘进工作面照明突然全部熄灭，电工检查发现照明综保装置显示漏电闭锁，下一步正确的处置是","options":["沿照明线路逐段排查绝缘和接线盒后处理漏电点","将综保装置漏电闭锁功能退出后逐路试送电","把照明变压器分接开关调高一档后试送电","将各灯具灯泡逐个取下后合闸观察是否恢复"],"answer":[0],"explanation":"知识点：照明综保漏电闭锁的处置。闭锁说明线路存在漏电，应逐段排查绝缘和接线盒找出漏电点，A正确。B退出闭锁送电会失去漏电保护；C调分接开关改变电压不解决漏电；D逐个取灯泡不能定位线路漏电点且操作危险。"},{"id":229,"type":"single","stem":"井下变电硐室高压开关柜检修时，验电环节的正确操作顺序是","options":["先验低压后验高压，先验近端后验远端","先验高压后验低压，先验远端后验近端","先验高压后验低压，先验近端后验远端","先验低压后验高压，先验远端后验近端"],"answer":[2],"explanation":"知识点为井下高压检修验电顺序。正确做法是先验高压侧再验低压侧，先验靠近电源侧（远端）再验负荷侧，防止反送电伤人。A项顺序颠倒且远近端搞错；B项先验低压不符合先高压原则；D项先验低压、先验远端均错。"},{"id":230,"type":"single","stem":"金属非金属矿山井下电气设备选用时，对存在瓦斯或可燃性粉尘聚集风险的采掘工作面，应优先选用","options":["矿用一般型设备并加强通风","矿用防爆型设备并按类别选型","矿用一般型设备并装设漏电保护","矿用增安型设备并定期测绝缘"],"answer":[1],"explanation":"知识点为井下爆炸性环境设备选型。瓦斯或可燃粉尘聚集场所必须按爆炸危险场所选用相应类别的矿用防爆设备。A项矿用一般型无防爆能力；C项漏电保护不能替代防爆；D项增安型仅适用于特定低风险场所，不能作为首选。"},{"id":231,"type":"single","stem":"井下电缆悬挂时，若巷道内同时敷设电力电缆与通信电缆，正确的布置方式是","options":["同侧悬挂，电力电缆在通信电缆上方","同侧悬挂，通信电缆在电力电缆上方","分别悬挂在巷道两侧，电力电缆靠行人侧","同钩悬挂，中间用绝缘隔板隔开"],"answer":[1],"explanation":"知识点为井下电缆敷设间距要求。电力电缆与通信电缆同侧敷设时，通信电缆应在上方，避免电磁干扰和故障影响。A项电力在上方易干扰通信；C项靠行人侧不符安全要求；D项同钩悬挂不符合分钩要求。"},{"id":232,"type":"single","stem":"井下检漏继电器动作后，重新送电前必须完成的关键步骤是","options":["将检漏继电器整定值调大后送电","查明漏电原因并排除故障后送电","对检漏继电器短接后送电","断开检漏继电器电源后直接送电"],"answer":[1],"explanation":"知识点为漏电保护动作后处置。检漏动作说明线路存在漏电，必须先查明并排除故障。A项调大整定值属掩盖故障；C项短接使保护失效；D项断开保护电源更危险。"},{"id":233,"type":"single","stem":"井下电气设备接地网上，任一点接地电阻的检测周期要求是","options":["每季度至少检测一次","每半年至少检测一次","每年至少检测一次","每两年至少检测一次"],"answer":[0],"explanation":"知识点为井下接地网检测周期。按规定任一点接地电阻每季度至少测定一次。B、C、D项周期均过长，无法及时发现接地劣化。"},{"id":234,"type":"single","stem":"井下同一供电线路中，一台开关同时控制两台电动机时，若两台电动机额定电流分别为20A和30A，开关整定值应按","options":["两台额定电流之和50A整定","较大一台30A整定","两台电流平均值25A整定","较大一台的1.5倍45A整定"],"answer":[0],"explanation":"知识点为多台电动机共用开关的过流整定。同时运行时应按总电流整定。B项仅按大者会误动；C项平均值无依据；D项倍数只适用于单台启动冲击，不适用于两台同时运行。"},{"id":235,"type":"single","stem":"井下电气着火时，若尚未停电，正确的灭火处置是","options":["立即用泡沫灭火器扑灭火焰","先切断电源再选用不导电灭火剂","直接用水冲灭并呼叫支援","用干砂覆盖同时保持供电"],"answer":[1],"explanation":"知识点为带电电气火灾处置。应先断电再灭火，选用干粉、二氧化碳等不导电灭火剂。A项泡沫导电；C项水导电；D项保持供电扩大危险。"},{"id":236,"type":"single","stem":"井下局部通风机实现风电闭锁的含义是","options":["风机停转时自动切断掘进工作面电源","风机停转时自动启动备用风机","风机启动时自动切断照明电源","风机停转时自动发出声光信号"],"answer":[0],"explanation":"知识点为风电闭锁功能。风机停止运转时，闭锁装置自动切断掘进工作面非本质安全型电源。B项是双风机自动切换，非闭锁；C项与闭锁无关；D项仅报警不能切断电源。"},{"id":237,"type":"single","stem":"井下电气设备隔爆外壳隔爆面出现轻微锈蚀时，正确的处理方式是","options":["用砂纸打磨至露出金属光泽后涂防锈油","用棉纱擦净后直接合盖使用","用锉刀修整锈蚀凹坑后继续使用","涂少量油漆覆盖锈蚀部位"],"answer":[0],"explanation":"知识点为隔爆面维护。轻微锈蚀可用砂纸打磨并涂防锈油，保持隔爆性能。B项未除锈影响隔爆；C项锉削改变隔爆面间隙；D项油漆影响隔爆面配合。"},{"id":238,"type":"single","stem":"井下停电检修作业中，在开关操作把手处悬挂\"有人工作，禁止合闸\"标示牌后，还需完成的关键安全措施是","options":["安排专人在开关处看守","对检修设备验电并放电","将检修设备外壳接地","测量检修设备绝缘电阻"],"answer":[1],"explanation":"知识点为停电检修安全措施。挂标示牌后必须验电、放电，确认无电才能作业。A项看守不能替代验电；C项外壳接地是设备保护接地，不等于验电放电；D项测绝缘是检修后项目。"},{"id":239,"type":"single","stem":"井下掘进工作面照明综保装置每班使用前应做的试验是","options":["短路试验和漏电试验","过载试验和短路试验","漏电试验和过载试验","绝缘试验和漏电试验"],"answer":[0],"explanation":"知识点为照明综合保护装置班前试验。每班使用前应做短路和漏电试验，确认保护可靠。B项过载试验非班前必做；C项过载非班前项；D项绝缘试验非班前操作。"},{"id":240,"type":"single","stem":"井下变电所内检修低压馈电开关时，验电确认无电后还应完成哪项操作才能开始拆线","options":["对可能反送电的电缆头加装绝缘护套","在开关负荷侧三相短接并接地","拉开上级隔离开关并挂警示牌","用万用表再次测量相间电阻"],"answer":[1],"explanation":"知识点是井下检修停电后的安全技术措施。验电后必须放电并三相短路接地，防止反送电和残余电荷伤人，故B正确。A绝缘护套不能泄放反送电能量；C挂警示牌属防误操作措施，不能替代接地；D测电阻不能代替接地保护。"},{"id":241,"type":"single","stem":"井下低压电网中，检漏继电器动作使馈电开关跳闸后，电工首先应做的是","options":["立即重新合闸试送电观察是否再跳","查找并排除漏电故障点后再送电","将检漏继电器退出运行后送电","测量电网绝缘电阻后直接恢复送电"],"answer":[1],"explanation":"知识点是漏电保护动作后的处置程序。检漏动作说明电网存在漏电，必须查明并排除故障后才能送电，故B正确。A盲目试送可能扩大事故；C退出检漏属严重违章；D只测绝缘不排除故障点仍可能带病送电。"},{"id":242,"type":"single","stem":"井下巷道内敷设电缆时，电缆与压风管、供水管在同一侧悬挂，正确的位置关系是","options":["电缆挂在管子上方约0.3米处","电缆挂在管子下方约0.3米处","电缆与管子并排同一高度悬挂","电缆挂在管子下方约0.1米处"],"answer":[0],"explanation":"知识点是井下电缆悬挂位置要求。电缆应挂在管路子上方，防止管路漏水淋湿电缆，故A正确。B挂在下方易受漏水影响；C同高度易相互碰撞磨损；D间距过小且位于下方，均不符合要求。"},{"id":243,"type":"single","stem":"井下电气设备接线嘴的密封圈内径与电缆外径配合时，正确的做法是","options":["密封圈内径比电缆外径小2毫米","密封圈内径与电缆外径一致","密封圈内径比电缆外径大1毫米","密封圈内径比电缆外径大3毫米"],"answer":[1],"explanation":"知识点是隔爆接线嘴密封圈配合要求。密封圈内径应与电缆外径一致，保证严密密封，故B正确。A内径过小会割伤电缆绝缘；C、D内径过大则密封不严，失去隔爆和防潮作用。"},{"id":244,"type":"single","stem":"井下使用的电气设备中，矿用一般型设备与矿用隔爆型设备的核心区别在于","options":["外壳材质是铸铁还是钢板","能否承受内部爆炸而不传爆","额定电压等级的高低不同","是否设置漏电保护装置"],"answer":[1],"explanation":"知识点是矿用设备防爆型式区别。隔爆型的核心是外壳能承受内部爆炸且不引燃外部爆炸性气体，故B正确。A外壳材质不是本质区别；C电压等级与防爆型式无必然对应；D漏电保护是附加保护，不是两者核心区别。"},{"id":245,"type":"single","stem":"井下移动式电气设备（如装岩机）的橡套电缆在作业中被砸伤露出芯线，正确的处置是","options":["用绝缘胶带缠绕包扎后继续使用","停电后截去损伤段重新做接头","立即停止使用并更换同规格电缆","将损伤处浸入冷补胶固化后使用"],"answer":[2],"explanation":"知识点是橡套电缆损伤处置。芯线外露属于严重损伤，必须更换电缆，故C正确。A缠绕胶带不能恢复绝缘强度；B井下截接电缆会形成接头隐患且不符合规程；D冷补胶不能修复已露芯线的电缆。"},{"id":246,"type":"single","stem":"井下变电所停电检修时，验电操作的正确顺序是","options":["先验高压侧再验低压侧","先验低压侧再验高压侧","先验负荷侧再验电源侧","先验电源侧再验负荷侧"],"answer":[2],"explanation":"知识点是验电顺序要求。验电应先验负荷侧后验电源侧，逐步确认无电，故C正确。A、B按电压等级验电不符合顺序原则；D先验电源侧若带电则直接危及操作人。"},{"id":247,"type":"single","stem":"井下某处照明综保装置频繁跳闸，电工检查发现是线路绝缘受潮，正确的处置是","options":["调大综保整定值后恢复送电","更换受潮线路并测试绝缘后送电","将综保改为手动复位后送电","暂时退出漏电保护功能后送电"],"answer":[1],"explanation":"知识点是照明综保频繁动作的故障处置。绝缘受潮必须更换或干燥处理线路，测试合格后送电，故B正确。A调大整定值掩盖故障；C改手动复位不能消除故障；D退出漏电保护属严重违章。"},{"id":248,"type":"single","stem":"井下某采区变电所一台馈电开关合闸后即跳闸，外观检查无明显异常，下一步最合理的处置是","options":["反复合闸三次观察是否稳定","拆开开关检查触头烧损情况","测量负荷侧绝缘并检查有无短路","更换同型号开关后直接送电"],"answer":[2],"explanation":"知识点是馈电开关合闸跳闸的排查思路。应先用仪表检测负荷侧绝缘和短路情况，判断故障性质，故C正确。A反复合闸可能扩大故障；B未判明原因先拆开关盲目；D换开关不排除外部故障仍会跳闸。"},{"id":249,"type":"multi","stem":"井下电气设备检修时，下列做法中符合安全要求的有","options":["停电后验电确认无电再放电","在开关操作把手挂“禁止合闸”牌","检修人员穿绝缘靴戴绝缘手套","对可能反送电的电缆头三相短路接地","检修完成后由监护人拆除接地线"],"answer":[0,1,3],"explanation":"知识点是井下检修安全技术措施。A验电放电、B挂禁止合闸牌、D三相短路接地均为必要措施，故正确。C穿绝缘靴手套是防触电辅助措施，但不能替代停电验电接地，不是本题核心要求；E接地线应由检修人员本人拆除并核对，由监护人单方拆除不符合程序。"},{"id":250,"type":"single","stem":"井下变电硐室中，一台矿用一般型低压开关柜需要更换电流互感器，作业前应首先完成的操作是","options":["确认上一级馈电开关已分闸并挂牌","拉开该开关柜内隔离开关并验电","用绝缘手套直接拆卸互感器二次线","通知调度后直接开始更换作业"],"answer":[0],"explanation":"知识点：井下电气检修停送电程序。正确项对：检修任何开关柜必须先切断上一级电源并执行挂牌，防止反送电。错误项错在哪：拉开本柜隔离开关不能替代上一级停电，可能仍带电；直接拆二次线有触电和开路高压危险；只通知调度不落实停电挂牌不能作业。"},{"id":251,"type":"single","stem":"矿用防爆电气设备隔爆外壳上的紧固螺栓缺少一颗时，正确的处置方式是","options":["用同规格普通螺栓临时补齐后送电","少一颗不影响防爆性能可继续运行","停止运行并补齐同规格专用螺栓","用铁丝绑扎固定后维持生产"],"answer":[2],"explanation":"知识点：隔爆外壳完整性与紧固件要求。正确项对：隔爆性能依赖外壳紧固完整，缺螺栓必须停止运行并补齐专用螺栓。错误项错在哪：普通螺栓强度和精度不满足隔爆要求；少一颗会破坏隔爆间隙；铁丝绑扎无法保证紧固力。"},{"id":252,"type":"single","stem":"井下电缆悬挂时，电缆与压风管、供水管在同一侧敷设且必须平行时，电缆应","options":["敷设在管子上方并保持0.1m以上距离","敷设在管子下方并保持0.1m以上距离","与管子贴紧并用同一挂钩固定","敷设在管子上方并保持0.3m以上距离"],"answer":[3],"explanation":"知识点：井下电缆与管路的敷设间距。正确项对：电缆应敷设在管子上方并保持0.3m以上距离，防止管路检修或漏水影响电缆。错误项错在哪：上方0.1m距离不足；下方敷设易受管路滴漏水侵害；与管子贴紧共用挂钩违反分挂要求。"},{"id":253,"type":"single","stem":"井下低压馈电线上装设漏电保护装置的主要作用是","options":["防止人身触电和漏电引起的火灾","替代接地保护作为唯一安全措施","提高供电电压的稳定性","减少电动机启动电流"],"answer":[0],"explanation":"知识点：井下漏电保护功能。正确项对：漏电保护用于限制漏电电流，防止触电和漏电火灾。错误项错在哪：漏电保护不能替代接地保护；与电压稳定无关；与启动电流无关。"},{"id":254,"type":"single","stem":"井下电气作业人员在检修高压开关时，验电操作的正确顺序是","options":["先验低压后验高压，先验近端后验远端","先验高压后验低压，先验远端后验近端","先验高压后验低压，先验近端后验远端","先验低压后验高压，先验远端后验近端"],"answer":[2],"explanation":"知识点：检修验电顺序。正确项对：应先验高压后验低压，先验近端后验远端，逐步确认无电。错误项错在哪：先低压后高压会遗漏高压危险；先远端后近端不符合由近及远确认原则。"},{"id":255,"type":"single","stem":"井下移动变电站高压侧电缆连接器在运行中发热冒烟，值班电工首先应","options":["立即用手拉脱连接器断开电源","切断上一级电源并报告调度","用水直接浇灭冒烟部位","打开连接器检查内部触头"],"answer":[1],"explanation":"知识点：井下电气故障应急处置。正确项对：先切断上一级电源并报告调度，防止事故扩大。错误项错在哪：带电拉脱连接器会产生电弧；用水浇带电设备会触电；带电打开连接器极危险。"},{"id":256,"type":"single","stem":"井下电气设备保护接地网中，接地干线截面选择应满足的要求是","options":["铜质不小于25mm²，钢质不小于50mm²","铜质不小于50mm²，钢质不小于100mm²","铜质不小于10mm²，钢质不小于25mm²","铜质不小于16mm²，钢质不小于35mm²"],"answer":[0],"explanation":"知识点：井下接地干线最小截面。正确项对：铜质不小于25mm²，钢质不小于50mm²。错误项错在哪：50/100偏大不符合常规要求；10/25和16/35偏小不能满足接地干线要求。"},{"id":257,"type":"single","stem":"井下照明变压器二次侧应采用的安全电压等级是","options":["127V或220V","36V或127V","220V或380V","12V或24V"],"answer":[1],"explanation":"知识点：井下照明安全电压。正确项对：井下照明常用36V或127V安全电压。错误项错在哪：127V或220V含非安全电压；220V/380V为动力电压；12V/24V不是井下照明常用等级。"},{"id":258,"type":"single","stem":"井下电气设备检修完成后送电前，必须完成的确认项目是","options":["所有检修人员撤离并摘除停电牌","设备外壳温度降至室温","测量绝缘电阻后即可送电","通知班组长后直接合闸"],"answer":[0],"explanation":"知识点：送电前确认程序。正确项对：必须确认人员撤离、摘牌后方可送电。错误项错在哪：外壳温度不是送电前提；只测绝缘不确认人员撤离不够；只通知班组长不能替代现场确认。"},{"id":259,"type":"single","stem":"井下变电所内一台矿用隔爆型馈电开关运行中跳闸，复电前应优先做的是","options":["查看开关液晶屏显示的故障代码并记录","直接合闸试送一次观察是否再跳","拉开上级隔离开关后再合闸","测量负荷侧绝缘电阻后合闸"],"answer":[0],"explanation":"知识点：隔爆馈电开关跳闸后的处置程序。正确项对在：先读取并记录故障代码，能判断跳闸原因，是复电前的首要步骤。错误项：直接合闸试送可能扩大故障范围；拉开上级隔离开关只是隔离电源，未查原因；测绝缘是下一步针对漏电故障的排查手段，不能替代先看故障信息。"},{"id":260,"type":"single","stem":"井下低压电缆与高压电缆在巷道同侧敷设时，应满足的间距要求是","options":["高低压电缆之间保持0.1m以上距离","高低压电缆之间保持0.2m以上距离","高低压电缆之间保持0.5m以上距离","高低压电缆之间保持1.0m以上距离"],"answer":[0],"explanation":"知识点：井下电缆敷设间距。正确项对在：高低压电缆同侧敷设时相互间距不小于0.1m。错误项：0.2m、0.5m、1.0m均非该场合规定间距，属把其他场合参数套用。"},{"id":261,"type":"single","stem":"井下电气作业中，验电环节的正确操作是","options":["用电压等级相符的验电器在检修设备进出线两侧分别验电","用一根验电器在检修设备进线侧验电即可","用万用表交流电压档代替验电器验电","用声光验电器在设备外壳上验电确认无电"],"answer":[0],"explanation":"知识点：验电操作要求。正确项对在：验电器电压等级须相符，且进出线两侧分别验电，防止反送电。错误项：只验一侧漏检反送电可能；万用表不能替代专用验电器；验外壳不能代替验导电部位。"},{"id":262,"type":"single","stem":"井下接地网上任一保护接地点的接地电阻值，其检测周期要求是","options":["每季度至少检测一次","每半年至少检测一次","每年至少检测一次","每两年至少检测一次"],"answer":[0],"explanation":"知识点：井下接地电阻检测周期。正确项对在：任一保护接地点的接地电阻每季度至少测定一次。错误项：半年、一年、两年均超过规定周期，属记错周期。"},{"id":263,"type":"single","stem":"井下检修电气设备时，停电后开关把手应处于的位置及挂牌要求是","options":["开关把手打到分断位置并悬挂“有人工作，禁止合闸”标示牌","开关把手打到分断位置并锁好开关柜门即可","开关把手打到分断位置并取下操作手柄随身携带","开关把手打到分断位置并派人在开关处看守"],"answer":[0],"explanation":"知识点：停电挂牌制度。正确项对在：分断位置加挂“有人工作，禁止合闸”标示牌是标准做法。错误项：只锁柜门、只取手柄、只派人看守都不能替代挂牌，且看守人可能离岗。"},{"id":264,"type":"single","stem":"矿用隔爆型电气设备接线盒内，电缆与接线端子的连接方式应选用","options":["电缆芯线压接接线端子后用螺栓紧固","电缆芯线直接缠绕在接线柱上拧紧","电缆芯线弯成圆环套入接线柱后拧紧","电缆芯线用焊锡焊在接线柱上"],"answer":[0],"explanation":"知识点：隔爆接线盒内导线连接。正确项对在：压接端子后螺栓紧固，接触可靠、不产生火花。错误项：缠绕、弯环套入接触电阻大易发热；焊接在井下振动环境易开裂。"},{"id":265,"type":"single","stem":"井下某掘进工作面照明综保装置频繁漏电跳闸，排查时首先应检查的是","options":["照明电缆及灯具的绝缘状况","综保装置的漏电动作整定值","照明变压器的容量是否匹配","供电电压是否波动过大"],"answer":[0],"explanation":"知识点：漏电跳闸排查顺序。正确项对在：频繁漏电跳闸多为线路或灯具绝缘下降，应先查绝缘。错误项：整定值、变压器容量、电压波动均不是频繁漏电跳闸的常见直接原因，属排查顺序放错。"},{"id":266,"type":"single","stem":"井下电气设备进行保护接地时，接地极与接地导线的连接应采用的连接方式是","options":["螺栓压接或焊接","绑扎后用胶带缠绕","用卡子夹紧不焊接","绞接后涂防锈漆"],"answer":[1],"explanation":"知识点：接地连接要求。正确项对在：接地极与接地导线必须螺栓压接或焊接，保证连接可靠。错误项：绑扎胶带、卡夹不焊、绞接涂漆均不能保证长期可靠导电。"},{"id":267,"type":"single","stem":"井下中央变电所一台高压开关柜检修完毕准备送电，送电前最后一步应确认的是","options":["拆除全部接地线并核对临时接地线数量","检查开关柜外观是否清洁","核对检修记录是否填写完整","通知调度室检修已结束"],"answer":[0],"explanation":"知识点：送电前检查程序。正确项对在：送电前必须拆除全部接地线并核对数量，防止带接地线合闸。错误项：清洁、记录、通知都是送电前应做工作，但不是最后一步的关键确认。"},{"id":268,"type":"single","stem":"井下变电所内检漏继电器动作后，在未查明原因前，值班电工首先应做的处置是","options":["按下复位按钮试送电一次","拉开该路馈电开关并挂停电牌","将该路负荷改接到另一台变压器","记录动作时间后继续监视运行"],"answer":[1],"explanation":"知识点：检漏继电器动作后的处置程序。漏电动作说明网络绝缘可能已破坏，正确做法是先停电挂牌，防止误送电扩大事故。按下复位试送电属于盲目试送，可能引发触电或瓦斯爆炸；改接负荷只是转移问题，漏电点仍在；仅记录后继续监视等于带故障运行，均属错误处置。"},{"id":269,"type":"single","stem":"井下电气设备的金属外壳与接地网连接时，其接地线应采用的最小截面要求是针对","options":["铜质接地干线","钢质接地支线","铝质接地连接线","电缆金属护套"],"answer":[1],"explanation":"知识点：井下保护接地线材质与截面规定。钢质接地支线因机械强度高、耐腐蚀，有明确的最小截面要求。铜质接地干线截面要求另有一档，不能套用；铝质材料在井下易氧化、连接不可靠，一般不作接地线；电缆金属护套可作辅助接地通路，但不能代替专用接地支线。"},{"id":270,"type":"single","stem":"井下低压馈电开关中，用于短路保护的主要元件是","options":["过流脱扣器","漏电闭锁模块","失压脱扣器","热继电器"],"answer":[0],"explanation":"知识点：低压开关保护元件的功能区分。过流脱扣器在短路大电流下瞬时动作切断电路，是短路保护主体。漏电闭锁模块管绝缘监视，不响应短路；失压脱扣器在电压消失时动作，属欠压保护；热继电器用于过载保护，动作有延时，不能承担短路瞬时切断。"},{"id":271,"type":"single","stem":"井下电缆悬挂时，电缆与压风管、供水管在同一侧敷设应保持的最小间距是","options":["0.1米","0.3米","0.5米","0.8米"],"answer":[1],"explanation":"知识点：井下电缆与管路的敷设间距要求。电缆与压风、供水管同侧时须保持0.3米以上间距，防止管路检修或泄漏影响电缆。0.1米过近易受碰撞和潮气侵蚀；0.5米和0.8米虽更安全但不符合规程规定的最小值，属参数记忆偏差。"},{"id":272,"type":"single","stem":"井下电气设备隔爆外壳的隔爆面出现轻微锈蚀，正确的处理方式是","options":["用砂纸打磨至露出金属光泽","涂少量防锈油后继续使用","用棉纱擦拭干净即可恢复","用铲刀刮除锈层后测量间隙"],"answer":[3],"explanation":"知识点：隔爆面锈蚀的处理与间隙检测。锈蚀会改变隔爆间隙，须先刮除锈层再测量间隙是否合格，才能判断能否使用。砂纸打磨会损伤隔爆面精度；只涂防锈油不除锈，间隙仍不合格；棉纱擦拭无法去除已形成的锈层，均不能保证隔爆性能。"},{"id":273,"type":"single","stem":"井下照明变压器二次侧应采用的安全电压等级中，用于手持行灯的是","options":["127伏","220伏","36伏","12伏"],"answer":[2],"explanation":"知识点：井下安全电压等级及适用场所。手持行灯在潮湿、狭窄的井下环境使用，规定采用36伏安全电压。127伏多用于固定照明网络，220伏为一般动力照明电压，均高于安全电压；12伏虽更安全但通常用于特别潮湿或金属容器内，不是井下手持行灯的标准等级。"},{"id":274,"type":"single","stem":"井下电气作业中，验电操作的正确顺序是","options":["先验低压后验高压，先验近端后验远端","先验高压后验低压，先验远端后验近端","先验高压后验低压，先验近端后验远端","先验低压后验高压，先验远端后验近端"],"answer":[2],"explanation":"知识点：验电操作顺序。正确顺序是先高压后低压、先近端后远端，因为高压危险更大应优先确认，近端更可能带电应先排除。其余三项颠倒顺序，会在未确认高压无电时接近设备，或先验远端导致近端带电被忽略，均存在触电风险。"},{"id":275,"type":"single","stem":"井下移动式电气设备的橡套电缆发生护套破损露出芯线时，正确的处置是","options":["用绝缘胶带缠绕破损处后继续使用","将该段电缆截除后重新连接并硫化","用冷补胶填充破损处后投入使用","降低负荷运行至检修班再处理"],"answer":[1],"explanation":"知识点：橡套电缆护套破损的修复要求。护套破损露出芯线后绝缘性能已破坏，必须截除损坏段重新连接并做硫化处理，恢复整体绝缘和机械强度。绝缘胶带缠绕、冷补胶填充都只是表面覆盖，不能恢复护套的防水和抗机械损伤能力；降负荷运行不能消除漏电和短路隐患。"},{"id":276,"type":"single","stem":"井下变电所停电检修时，在已停电的开关操作把手上悬挂的标示牌应写","options":["止步，高压危险","有人工作，禁止合闸","在此工作，注意安全","设备检修，请勿靠近"],"answer":[1],"explanation":"知识点：检修停电安全措施中的标示牌使用。在已停电的开关操作把手上应悬挂有人工作禁止合闸牌，防止他人误送电。止步高压危险牌用于遮栏或室外构架；在此工作牌用于工作地点；设备检修请勿靠近语义含糊，均不能替代防误送电的专用标示牌。"},{"id":277,"type":"single","stem":"井下电气设备运行中闻到焦糊味且外壳温度明显升高，电工的正确处置是","options":["立即断电检查并报告调度","加强通风降温后继续观察","记录温度变化待检修班处理","切换备用设备后检查故障设备"],"answer":[0],"explanation":"知识点：电气设备异常发热的应急处理。焦糊味加外壳过热说明绝缘可能已过热分解，应立即断电并报告，防止发展为短路或火灾。通风降温只是掩盖现象；仅记录不处理会错过处置时机；切换备用设备前未断电，故障设备仍带电，可能引发事故。"},{"id":278,"type":"single","stem":"井下电气设备保护接地系统中，接地极与接地干线连接处采用的连接方式是","options":["螺栓压接并涂防锈油","焊接并做防腐处理","绞接后缠绝缘带","卡箍夹紧后刷漆"],"answer":[1],"explanation":"知识点：接地装置连接工艺要求。接地极与接地干线连接必须焊接并做防腐处理，保证连接可靠、长期不松动。螺栓压接在井下潮湿环境易锈蚀松动；绞接加绝缘带机械强度和导电性都不足；卡箍夹紧接触电阻大且易腐蚀，均不符合接地连接要求。"},{"id":279,"type":"single","stem":"井下中央变电所的高压电缆连接器（接线盒）在运行中出现轻微放电声，值班电工首先应做的是","options":["立即汇报调度并做好记录，安排停电检查","打开接线盒观察放电部位","紧固接线盒外部螺栓消除间隙","降低该回路负荷继续观察运行"],"answer":[0],"explanation":"知识点：井下高压设备异常运行处置。出现放电声说明绝缘可能已劣化，应立即汇报并申请停电检查，严禁带电开盖。选项B带电打开接线盒极易触电；选项C外部紧固不能消除内部放电；选项D降负荷运行掩盖了隐患，放电会继续发展。"},{"id":280,"type":"single","stem":"井下电气设备选择中，用于有瓦斯或矿尘爆炸危险场所的设备必须满足的条件是","options":["具备矿用防爆型标志并取得相应合格证","外壳采用加厚钢板焊接结构","额定电压不高于低压等级","安装位置高于巷道底板1米以上"],"answer":[0],"explanation":"知识点：爆炸危险场所电气设备选型。必须选用具有矿用防爆标志和合格证的设备，防爆性能由专门结构和认证保证。选项B加厚外壳不等于防爆；选项C电压等级与防爆性能无直接关系；选项D安装高度不是防爆条件。"},{"id":281,"type":"single","stem":"井下低压电网采用检漏保护装置的主要作用是","options":["当电网对地绝缘下降到危险值时自动切断电源","当电网发生过载时自动切断电源","当电网发生短路时自动切断电源","当电网电压偏低时自动提升电压"],"answer":[0],"explanation":"知识点：井下低压检漏保护。检漏装置监测电网对地绝缘，绝缘降低到危险值时动作跳闸，防止触电和漏电引爆。选项B过载由过流保护承担；选项C短路由短路保护承担；选项D不是检漏装置功能，电压调节另有措施。"},{"id":282,"type":"single","stem":"井下电气设备的保护接地网中，主接地极和局部接地极之间应满足的要求是","options":["用接地干线连接成完整的接地网","各自独立接地互不连接","只通过设备外壳自然连通","经开关的金属底板跨接连通"],"answer":[0],"explanation":"知识点：井下保护接地网。主接地极与局部接地极必须用接地干线连接成完整接地网，才能降低接地电阻、保证保护可靠。选项B独立接地不能形成等电位；选项C外壳自然连通不可靠；选项D经底板跨接不符合接地网要求。"},{"id":283,"type":"single","stem":"井下电缆与电气设备连接时，对电缆护套的处理要求是","options":["护套伸入设备接线腔并做密封，防止潮气进入","剥除护套后芯线直接接入端子即可","护套在设备外部剥除并用胶带缠紧","护套剥至接线端子处保证散热"],"answer":[0],"explanation":"知识点：井下电缆连接工艺。护套应伸入接线腔并密封，防止井下潮气和粉尘进入引起绝缘下降。选项B失去护套保护且无密封；选项C外部缠绕不能密封接线腔；选项D护套剥到端子处无法密封，潮气直接侵入。"},{"id":284,"type":"single","stem":"井下照明变压器二次侧采用的安全电压等级，在金属非金属矿山井下一般不应高于","options":["127伏","220伏","380伏","660伏"],"answer":[0],"explanation":"知识点：井下照明安全电压。井下照明变压器二次侧一般采用127V及以下安全电压，降低触电危险。选项B、C、D均为动力或较高电压等级，直接用于井下照明会显著增加触电风险。"},{"id":285,"type":"single","stem":"井下电气设备运行中，电工发现漏电保护装置频繁动作，正确的处置是","options":["查明漏电原因并处理后再送电","将漏电保护退出运行继续供电","调大漏电保护动作值减少动作","改用手动复位方式维持供电"],"answer":[0],"explanation":"知识点：漏电保护动作后的处置。频繁动作说明电网有漏电隐患，必须查明原因处理后送电。选项B退出保护属严重违章；选项C调大动作值会失去保护作用；选项D手动复位不解决漏电问题，隐患仍在。"},{"id":286,"type":"single","stem":"井下进行电气设备停电检修时，在开关操作把手上悬挂的标示牌内容应为","options":["禁止合闸，有人工作","高压危险，请勿靠近","设备运行，请勿操作","注意安全，小心触电"],"answer":[0],"explanation":"知识点：检修安全标示牌。停电检修时应在操作把手上悬挂“禁止合闸，有人工作”标示牌，防止误送电。选项B、C、D均不是防止误合闸的专用标示内容，起不到阻止他人操作的作用。"},{"id":287,"type":"single","stem":"某矿井下采区变电所一台馈电开关跳闸后，电工未查明原因直接强送电两次均跳闸，第三次送电前正确的下一步操作是","options":["停止送电，汇报调度并查找故障原因","换用更大容量的开关再送电","将保护整定值调大后送电","拉开隔离开关后合上馈电开关试送"],"answer":[0],"explanation":"知识点：开关跳闸后的故障处置。连续跳闸说明线路或设备存在故障，应停止强送，汇报调度并查找原因。选项B换大容量开关会失去保护配合；选项C调大整定值掩盖故障；选项D拉开隔离开关后合馈电开关仍属盲目试送，不能查明故障。"},{"id":288,"type":"single","stem":"井下变电硐室中，一台矿用一般型低压开关柜的金属外壳接地端子应优先连接到下列哪一部位","options":["硐室主接地极的接地干线","就近的局部接地极","相邻开关柜的外壳螺栓","电缆钢带铠装层"],"answer":[0],"explanation":"知识点：井下保护接地系统要求所有电气设备外壳接至总接地网。主接地极接地干线构成总接地网，能保证故障电流可靠入地并降低接触电压。局部接地极仅用于某些移动设备或远离主接地网处，不能替代总网；外壳螺栓连接只是等电位，不能作为接地通路；电缆钢带是电缆自身部件，不是设备接地体。"},{"id":289,"type":"single","stem":"井下电气检修中，验电确认无电后，对可能反送电的线路还应采取的措施是","options":["装设接地线并悬挂标示牌","测量绝缘电阻确认","断开本侧隔离开关","通知调度后即可作业"],"answer":[0],"explanation":"知识点：停电、验电、放电、装设接地线、悬挂标示牌是检修安全技术措施。验电只能证明当时无电，反送电风险需靠接地线泄放并加锁挂牌防止误送。测绝缘不能防反送电；只断本侧隔离开关不能防止另一侧反送；通知调度不等于完成安全措施。"},{"id":290,"type":"single","stem":"井下使用的矿用隔爆型电气设备，其隔爆外壳隔爆面的主要作用是","options":["阻止内部爆炸火焰直接点燃外部爆炸性气体","防止外部潮气进入设备内部","增强外壳机械强度防止碰撞变形","屏蔽内部电弧对外部设备的电磁干扰"],"answer":[0],"explanation":"知识点：隔爆型设备的隔爆面通过间隙和长度使内部爆炸产物降温、去焰，不能点燃壳外爆炸性气体。防潮靠密封结构；机械强度是附带性能；电磁屏蔽不是隔爆面功能。"},{"id":291,"type":"single","stem":"井下电工发现一台运行中的低压电动机外壳温度明显偏高且伴有焦糊味，首先应采取的措施是","options":["立即停车并断开电源检查","继续运行观察温度变化","打开外壳通风降温","降低负荷继续运行"],"answer":[0],"explanation":"知识点：电动机过热伴焦糊味可能为绕组绝缘损坏或过载，继续运行会扩大故障甚至引发火灾。停车断电是防止事故扩大的首要措施；观察、开壳通风、降负荷运行都不能消除绝缘故障根源，反而延误处理。"},{"id":292,"type":"single","stem":"井下电缆连接时，对橡套电缆的导体连接要求是","options":["采用与导体材质相同的压接或焊接并恢复绝缘","将两导体直接绞接后包缠绝缘胶带","用铜铝过渡接头连接并缠防水胶带","用螺栓压板压紧后不另做绝缘"],"answer":[0],"explanation":"知识点：电缆导体连接必须保证电气连续性和机械强度，连接后要恢复绝缘和护套。绞接接触电阻大且不牢固；铜铝直接连接会电化腐蚀，须用过渡接头但还需恢复绝缘；螺栓压紧不恢复绝缘不能保证绝缘性能。"},{"id":293,"type":"single","stem":"井下接地网中，接地电阻的测量应在下列哪种状态下进行","options":["接地极与接地干线连接完好的运行状态","断开接地干线单独测量接地极","雷雨天气测量以模拟最不利条件","设备停电且接地线拆除后测量"],"answer":[0],"explanation":"知识点：接地电阻测量应在接地系统完整连接状态下进行，才能反映实际接地效果。断开干线测的是单个接地极；雷雨天测量不安全且不反映常态；拆除接地线测量失去意义。"},{"id":294,"type":"single","stem":"井下照明线路中，127V照明系统必须采用的保护措施是","options":["漏电保护和短路保护","过压保护和欠压保护","断相保护和过载保护","防雷保护和静电保护"],"answer":[0],"explanation":"知识点：井下照明系统电压低但环境潮湿，主要危险是漏电和短路，必须设漏电保护和短路保护。过压欠压保护不是照明系统必备；断相过载针对电动机；防雷静电不是井下照明主要保护。"},{"id":295,"type":"single","stem":"井下电气设备防爆检查中，发现隔爆外壳紧固螺栓缺失一颗，正确的处理是","options":["立即停止该设备运行并补装同规格螺栓","用铁丝临时绑扎固定后继续运行","用稍长螺栓代替并加垫片","用密封胶封堵螺栓孔后运行"],"answer":[0],"explanation":"知识点：隔爆外壳紧固螺栓数量和规格影响隔爆性能，缺失会使隔爆间隙失效。必须停运并补装同规格螺栓；铁丝绑扎、代用螺栓、封堵螺栓孔都会破坏隔爆性能。"},{"id":296,"type":"single","stem":"井下低压电网中，漏电保护装置动作后，正确的处理程序是","options":["查明漏电原因并排除故障后再送电","直接复位重合闸送电","将漏电保护退出后送电","更换漏电保护装置后送电"],"answer":[0],"explanation":"知识点：漏电保护动作说明电网存在漏电故障，必须查清原因排除故障后方可送电。直接复位、退出保护、更换装置都是绕过保护，可能导致触电或瓦斯爆炸事故。"},{"id":297,"type":"single","stem":"井下变电硐室中，一台低压开关的隔爆外壳紧固螺栓缺失两颗，其余螺栓均已拧紧，此时对该开关的正确处置是","options":["停电后补齐同规格螺栓并确认拧紧再恢复送电","用铁丝临时绑扎固定外壳后继续送电运行","用附近找到的普通螺栓代替后送电运行","暂不处理，待下次检修时一并补齐螺栓"],"answer":[0],"explanation":"知识点：隔爆外壳的隔爆性能依赖紧固件的完整性和规定力矩，缺螺栓会使外壳失去隔爆能力。正确项对：必须停电、补齐同规格螺栓并拧紧，才能恢复隔爆性能。错误项一错在铁丝无法保证隔爆间隙和强度，属带病运行；错误项二错在普通螺栓的强度、规格不匹配，不能保证隔爆面压紧；错误项三错在隔爆缺陷属立即处理的隐患，不能拖延到下次检修。"},{"id":298,"type":"single","stem":"井下电气检修中，验电确认无电后，对可能反送电的开关和可能来电的电缆端头，下一步应优先做的是","options":["对可能反送电的各侧装设接地线并悬挂标示牌","用绝缘胶带包裹裸露端头后开始检修作业","安排专人在开关旁看守，防止他人误合闸","测量绝缘电阻确认无电后直接开始检修"],"answer":[0],"explanation":"知识点：检修停电后的安全措施顺序为停电、验电、放电、装设接地线、悬挂标示牌和装设遮栏。正确项对：验电后必须对可能反送电的各侧装设接地线并挂标示牌，防止突然来电和感应电伤人。错误项一错在绝缘胶带不能替代接地线，无法泄放突然来电；错误项二错在看守不能阻止误合闸，且不能消除反送电；错误项三错在测绝缘电阻不能代替接地，且测绝缘本身不能保证无电。"},{"id":299,"type":"single","stem":"某矿井下采区变电所一台馈电开关频繁跳闸，电工到现场后未查明原因，先将漏电保护整定值调大后恢复送电，该做法的主要问题是","options":["擅自调大漏电保护整定值会掩盖真实漏电故障，扩大触电和引爆风险","调大整定值后开关不再跳闸，说明故障已排除，可以正常送电","漏电保护整定值应由操作工根据负荷情况随时调整","频繁跳闸说明开关容量偏小，应更换更大容量开关"],"answer":[0],"explanation":"知识点：漏电保护整定值由设计确定，不得擅自调整，跳闸说明存在漏电或绝缘缺陷。正确项对：调大整定值会掩盖真实漏电故障，使保护失效，扩大触电和引爆风险。错误项一错在故障未排除，不跳闸不等于安全；错误项二错在整定值不允许操作工随意调整；错误项三错在跳闸原因未查明，不能简单归为容量偏小。"},{"id":300,"type":"multi","stem":"井下变电硐室一台低压馈电开关因过流跳闸后，电工排查发现负荷侧电缆有一处绝缘破损但尚未接地，现场仅有冷补胶带和热缩管两种修复材料，下列处置做法中正确的有","options":["停电并验电后，用绝缘电阻表测该电缆相间及相对地绝缘电阻，确认数值合格再恢复送电","直接更换破损段电缆，中间接头采用热缩管热缩并做绝缘和防水处理","用冷补胶带缠绕破损处三层后送电，并加强该回路日常巡检频次","先合闸试送一次，若不再跳闸则视为绝缘已恢复，可继续运行"],"answer":[0,1],"explanation":"本题考查井下电缆绝缘破损后的处置程序：正确做法是先停电验电、测绝缘确认合格，或直接更换破损段并规范做接头。选项A对，验电测绝缘是判断能否送电的依据；选项B对，更换破损段并用热缩管做规范接头可恢复绝缘和防水性能。选项C错，冷补胶带只能作临时应急，不能替代规范绝缘处理即送电；选项D错，绝缘破损未处理就试送电属于带隐患合闸，跳闸与否不能证明绝缘已恢复。"}]}